Introduction

In the ever-evolving landscape of electrical components, the Schneider C11N6TM063B emerges as a vital player. As part of Schneider Electric’s comprehensive product range, this component is indispensable for various electrical systems. But what exactly is the Schneider C11N6TM063B, and why is it so crucial? Let’s delve into its features and applications.

What is Schneider C11N6TM063B?

it is a high-performance electrical component engineered for optimal efficiency and reliability. This advanced component boasts specifications that cater to the needs of modern electrical systems. Key features include robust durability, enhanced safety protocols, and superior energy efficiency.

Historical Background of Schneider Electric

Schneider Electric, founded in 1836, has transformed from a small iron and steel company into a global leader in energy management and automation. Throughout the years, the company has introduced numerous innovative solutions, with it exemplifying its dedication to quality and innovation.

Technical Specifications

it is renowned for its impressive technical specifications. It features a sturdy build designed to manage substantial electrical loads. Key specifications include:

  • Voltage Rating: [Specific Voltage]
  • Current Rating: [Specific Current]
  • Material Composition: [Material Details]

When compared to other models, the C11N6TM063B excels in efficiency and longevity.

Key Features of Schneider C11N6TM063B

Durability

it is built to endure, capable of withstanding harsh environments without compromising performance, making it ideal for both industrial and commercial applications.

Safety

Safety is paramount in electrical components, and the C11N6TM063B excels with its advanced safety features, such as [specific safety features], ensuring comprehensive user protection.

Efficiency

Efficiency is another hallmark of it. It minimizes energy loss and maximizes performance, making it a cost-effective option for a variety of applications.

Applications of Schneider C11N6TM063B

Industrial Use

In industrial settings, it is commonly utilized in machinery and control systems. Its reliability is crucial for maintaining continuous operations and productivity.

Residential Use

For residential purposes, this component can be integrated into home electrical systems, providing safe and efficient power distribution.

Commercial Use

In commercial environments, it supports complex electrical networks, enhancing overall energy management and reducing operational costs.

Installation Process

Installing it is straightforward if you follow these steps:

  1. Preparation: Ensure all necessary tools and safety gear are ready.
  2. Mounting: Secure the component in the designated spot.
  3. Wiring: Connect the wires as per the wiring diagram.
  4. Testing: Verify the installation by conducting thorough tests.

Common challenges, such as [specific challenge], can be addressed with [specific solution].

Maintenance Tips

To keep it in top condition:

  • Regular Inspections: Check for any signs of wear or damage.
  • Updates: Keep the firmware and software updated to the latest versions.
  • Troubleshooting: For issues like [common issue], refer to the manual or contact support.

Benefits of Using Schneider C11N6TM063B

Cost-Effectiveness

Although the initial investment may be higher, the long-term savings from reduced maintenance and high energy efficiency make it a smart choice.

Long-Term Reliability

With a lifespan that surpasses many competitors, itensures fewer replacements and repairs.

Enhanced Performance

Optimized for performance, this component supports high-load operations seamlessly.

SKU: C11N6TM063B Category: Brand:
Main
RangeComPacT new generation
Product nameComPacT NSXm new generation
Range of productComPacT NSXm new generation
Device short nameNSXm 63N
product or component typeCircuit breaker
Device applicationDistribution
poles description4P
Protected poles description3D
Neutral positionLeft
[In] rated current63 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelN 50 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity90 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole5.58 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection terminalsCompression lug/busbar
Connection pitch35 mm with spreaders
27 mm without spreaders
9 mm pitches12 module
Trip unit rating63 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
Neutral protection settingsNo protection (3D)
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range800 A
Earth-leakage protectionWithout
Number of slots for electrical auxiliaries1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signallingFlag (green) for presence of auxiliary contacts
Width (W)108 mm
Height (H)137 mm
Depth (D)80 mm
net weight1.42 kg
ColourGrey (RAL 7016)
Environment
StandardsEN/IEC 60947
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height13 cm
Package 1 Width13 cm
Package 1 Length21 cm
Package 1 Weight1.48 kg
Unit Type of Package 2S03
Number of Units in Package 26
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight10.19 kg
Unit Type of Package 3P12
Number of Units in Package 3144
Package 3 Height150 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight254.49 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11N6TM063B | Circuit breaker, ComPacT NSXm 63N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 63A, lugs/busbars”

There are no reviews yet.