Schneider C12B44V160L | circuit breaker ComPacT NSXm B (25 kA at 415 VAC), 4P 4d, 160 A rating Micrologic 4.1 trip unit, EverLink connectors

Availability:

Out of stock


Schneider C12B44V160L | circuit breaker ComPacT NSXm B (25 kA at 415 VAC), 4P 4d, 160 A rating Micrologic 4.1 trip unit, EverLink connectors

37,122 EGP 58,003 EGP

Out of stock

Compare

Schneider C12B44V160L: The Ultimate Guide

Introduction

Choosing the right circuit breaker is essential for ensuring electrical safety and efficiency. Today, we’re diving into the details of the Schneider C12B44V160L, a top-tier circuit breaker known for its exceptional features and reliability. Whether you’re an electrician, a homeowner, or a business owner, understanding this device can help you make informed decisions for your electrical needs.

Understanding the Basics

What is a Circuit Breaker?

A circuit breaker is an automatic electrical switch designed to protect electrical circuits from damage caused by overcurrent or short circuits. Its basic function is to interrupt current flow after a fault is detected, preventing potential fires and equipment damage.

Overview of Schneider Electric

Schneider Electric is a global leader in energy management and automation. With a history spanning over 180 years, the company is renowned for its innovative solutions that improve efficiency and sustainability in energy usage.

Features of Schneider C12B44V160L

Design and Construction

The Schneider C12B44V160L boasts a robust and compact design, making it suitable for various applications. Its construction ensures durability and reliability, even in demanding environments.

Technical Specifications

The C12B44V160L is a 160A, 44kA, four-pole circuit breaker. It operates on a 240/415V AC system and is designed to provide excellent performance under various load conditions.

Safety Features

Safety is paramount with the C12B44V160L. It includes features like arc fault protection, thermal-magnetic trip units, and a high breaking capacity, ensuring maximum protection against electrical faults.

Benefits of Using Schneider C12B44V160L

Enhanced Safety

With advanced safety features, the C12B44V160L significantly reduces the risk of electrical fires and equipment damage. Its quick response to faults ensures minimal disruption.

Reliability

Built to last, this circuit breaker offers consistent performance, making it a reliable choice for both residential and commercial applications.

Ease of Installation

Designed with the user in mind, the C12B44V160L is straightforward to install. Its compact size and clear labeling make the installation process hassle-free.

Applications of Schneider C12B44V160L

Residential Use

In homes, the C12B44V160L ensures the safety of electrical systems, protecting appliances and preventing potential hazards.

Commercial Use

For businesses, this circuit breaker provides reliable protection for critical electrical systems, ensuring smooth operations.

Industrial Use

In industrial settings, the C12B44V160L can handle high loads and harsh conditions, safeguarding expensive equipment and maintaining productivity.

Installation Process

Pre-installation Requirements

Before installing the C12B44V160L, ensure you have the right tools and understand the electrical layout. It’s crucial to turn off the main power supply to prevent accidents.

Step-by-Step Installation Guide

  1. Turn off the main power supply.
  2. Mount the circuit breaker in the appropriate panel.
  3. Connect the input and output wires securely.
  4. Ensure all connections are tight and properly insulated.
  5. Turn on the main power supply and test the circuit breaker.

Post-installation Checks

After installation, conduct thorough checks to ensure everything is working correctly. Test the breaker by simulating faults to confirm its responsiveness.

Maintenance and Troubleshooting

Routine Maintenance Tips

Regularly inspect the circuit breaker for signs of wear and tear. Clean the contacts and ensure there are no loose connections. Schedule periodic professional inspections to maintain optimal performance.

Common Issues and Solutions

If the breaker frequently trips, it might indicate an overloaded circuit or a short circuit. Check the connected devices and wiring for faults. If the problem persists, consult a professional.

When to Seek Professional Help

If you encounter complex issues or are unsure about troubleshooting steps, it’s best to seek professional assistance to avoid further complications.

SKU: C12B44V160L Category: Brand:
Main
RangeComPacT new generation
Product nameComPacT NSXm new generation
Range of productComPacT NSXm new generation
Device short nameNSXm 160B
product or component typeEarth leakage circuit breaker
Device applicationDistribution
poles description4P
Protected poles description4D
Neutral positionLeft
[In] rated current160 A at 40 °C
[Ue] rated operational voltage440 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity50 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelB 25 kA 415 V AC
Trip unit nameMicroLogic 4.1
Trip unit technologyElectronic
Trip unit protection functionsLSoIR
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity50 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole12.21 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection terminals1 Everlink lug wire size 2.5…70 mm², fine stranded copper
1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
Connection pitch35 mm with spreaders
27 mm without spreaders
9 mm pitches12 module
Trip unit rating160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range63…160 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range200 s at 1.5 x Ir
8 s at 6 x Ir
5 s at 7.2 x Ir
Neutral protection settings1 x Ir (4D)
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5…10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range2000 A
Earth-leakage protectionIntegrated
Earth-leakage protection classClass A
Class AC
Earth-leakage protection sensitity adjustment type IΔnAdjustable
[IΔn] earth-leakage protection sensitivity adjustment range30 mA
100 mA
300 mA
500 mA
1 A
3 A
5 A
Earth-leakage sensitivity30 mA for class A
100 mA for class A
300 mA for class A
500 mA for class A
1 A for class A
30 mA for class AC
100 mA for class AC
300 mA for class AC
500 mA for class AC
1 A for class AC
3 A for class AC
5 A for class AC
Earth-leakage protection time delay adjustement type ΔtAdjustable
[Δt] Earth-leakage protection time delay adjustment range0 ms
60 ms
150 ms
500 ms
1000 ms
Number of slots for electrical auxiliaries1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signallingFlag (green) for presence of auxiliary contacts
Width (W)108 mm
Height (H)144 mm
Depth (D)80 mm
net weight1.63 kg
ColourGrey (RAL 7016)
Environment
StandardsEN/IEC 60947
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
ambient air temperature for storage-40…85 °C
Relative humidity0…95 %
Operating altitude2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.0 cm
Package 1 Width13.0 cm
Package 1 Length19.0 cm
Package 1 Weight1.792 kg
Unit Type of Package 2S03
Number of Units in Package 24
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight7.556 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C12B44V160L | circuit breaker ComPacT NSXm B (25 kA at 415 VAC), 4P 4d, 160 A rating Micrologic 4.1 trip unit, EverLink connectors”

There are no reviews yet.