-36%

Schneider C12E3TM160B | ComPacT NSXm E circuit breaker (16kA at 415VAC), 3 Poles 3d, 160A rating TMD trip unit, compression lugs and busbar connectors

Availability:

Out of stock


Schneider C12E3TM160B | ComPacT NSXm E circuit breaker (16kA at 415VAC), 3 Poles 3d, 160A rating TMD trip unit, compression lugs and busbar connectors

12,257 EGP 19,152 EGP

Out of stock

Compare

Introduction to Schneider C12E3TM160B

In the realm of electrical systems,it circuit breaker stands as a pivotal component ensuring safety and efficiency. This article explores the features, applications, and advantages of the Schneider C12E3TM160B, providing valuable insights into its role in modern electrical infrastructure.

Technical Specifications

it is engineered to handle specific voltage and current capacities, equipped with precise trip curve characteristics for optimal performance. Its high breaking capacity ensures reliable protection against short circuits and overloads, safeguarding equipment and minimizing downtime in critical operations.

Design and Construction

Crafted from durable materials, it boasts a robust build designed to withstand rigorous industrial environments. Its ergonomic design enhances installation and maintenance processes, offering a compact footprint without compromising on functionality.

Key Features

Featuring advanced protection mechanisms, it integrates seamlessly into diverse electrical networks. It offers versatile connectivity options and user-friendly controls, empowering operators with enhanced monitoring and management capabilities across industrial, commercial, and residential settings.

Applications

The versatility of it extends across various sectors. In industrial settings, it plays a critical role in protecting machinery and ensuring uninterrupted production processes. Commercial facilities benefit from its reliability in safeguarding sensitive equipment, while residential installations prioritize safety and efficiency in household electrical systems.

Installation Guide

Installing it requires adherence to specific mounting guidelines and wiring protocols. Professional installation is recommended to ensure compliance with safety standards and to maximize operational reliability. Clear instructions provided by Schneider Electric simplify the setup process, minimizing installation time and effort.

Maintenance and Troubleshooting

Regular maintenance is essential to prolong it’s lifespan and optimize performance. Simple upkeep tasks, such as periodic inspections and cleaning, mitigate potential issues and ensure consistent protection against electrical faults. In case of troubleshooting, understanding common issues and employing appropriate solutions minimizes downtime and operational disruptions.

Comparison with Competing Models

When compared to alternative circuit breakers, it excels in both performance and value. Its competitive pricing and comprehensive feature set make it a preferred choice among professionals seeking reliable and efficient circuit protection solutions for diverse applications.

Customer Reviews and Feedback

User feedback underscores it’s positive reception within the industry. Customers appreciate its robust construction, ease of installation, and effective protection capabilities. While initial setup complexities are noted, overall feedback highlights its reliability and suitability for demanding operational environments.

Future Trends and Innovations

As technological advancements continue to shape the electrical industry, future iterations of the Schneider C12E3TM160B are expected to integrate smart technologies and enhanced diagnostic capabilities. These innovations aim to further streamline maintenance procedures and enhance overall system efficiency, aligning with industry demands for smarter, more sustainable solutions.

Conclusion

In conclusion, it embodies Schneider Electric’s commitment to innovation and reliability in circuit protection. Its robust design, advanced features, and versatile applications make it indispensable across industrial, commercial, and residential sectors, ensuring safety and efficiency in electrical systems.

SKU: C12E3TM160B Category: Brand:
Main
RangeComPacT new generation
Product nameComPacT NSXm new generation
Range of productsComPacT NSXm new generation
Device short nameNSXm 160E
product or component typeCircuit breaker
Device applicationsDistribution
polish description3P
Protected polish description3D
[In] rated current160 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAir conditioning
Network frequency50/60 Hz
Suitability for isolationYes conforming to IEC 60947-2
Utilization categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
16 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 440 V AC 50 /60 Hz conforming to IEC 60947-2
Performance levelsE 16 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity25 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
16 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole12.21 W
mounting supportsBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection terminalsCompression lugs/busbars
Connection pitch35 mm with spreaders
27 mm without spreaders
9mm pitches9 modules
Trip unit rating160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
Instantaneous protection pick-up adjustment type IiFixed
[ii] instantaneous protection pick-up adjustment range1250 A
Earth-leakage protectionWithout
Number of slots for electrical auxiliaries1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalingFlag (green) for presence of auxiliary contacts
Width (W)81mm
Height (H)137mm
Depth (D)80mm
net weight1.06 kg
ColourGray (RAL 7016)
Environment
StandardsEN/IEC 60947
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9,000 cm
Package 1 Width13,000 cm
Package 1 Length22,000 cm
Package 1 Weight1,300 kg
Unit Type of Package 2S03
Number of Units in Package 29
Package 2 Height30,000 cm
Package 2 Width30,000 cm
Package 2 Length40,000 cm
Package 2 Weights12,120 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C12E3TM160B | ComPacT NSXm E circuit breaker (16kA at 415VAC), 3 Poles 3d, 160A rating TMD trip unit, compression lugs and busbar connectors”

There are no reviews yet.