-36%

Schneider C12N6TM125L | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 125A, EverLink lugs

Schneider Electric
Availability:

Out of stock


Schneider C12N6TM125L | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 125A, EverLink lugs

20,283 EGP 31,692 EGP

Out of stock

Compare

Schneider C12N6TM125L: An In-Depth Guide

Introduction

it is a highly regarded electrical device from Schneider Electric, designed to meet the demands of modern electrical systems with its advanced features and reliable performance. This article explores its key specifications, features, applications, installation guidelines, and more.

Key Specifications

Power Rating and Voltage

The Schneider C12N6TM125L operates at [specify power rating] and [voltage details], ensuring it can handle a wide range of electrical applications effectively.

Dimensions and Design

With dimensions of [specify dimensions], the device is compact yet robust, suitable for various installation environments.

Environmental Considerations

It is engineered to operate efficiently in [mention environmental conditions], ensuring durability and reliable performance.

Features and Benefits

Advanced Protection Features

Equipped with [list advanced protection features], the Schneider C12N6TM125L ensures enhanced safety and protection for connected equipment.

High Efficiency

It boasts [highlight efficiency features], optimizing energy usage and reducing operational costs.

User-Friendly Interface

Featuring [describe user interface features], the device offers intuitive operation and simplified maintenance.

Applications

Industrial Applications

In industrial settings, the Schneider C12N6TM125L excels in [list industrial applications], providing reliable electrical distribution and protection.

Commercial Applications

For commercial installations, such as [mention commercial settings], it offers efficient power management and safety features.

Residential Applications

In residential environments, homeowners benefit from [describe residential applications], ensuring safe and efficient electricity distribution.

Installation and Maintenance

Installation Requirements

Installing the Schneider C12N6TM125L involves [outline installation requirements], adhering to industry standards and safety regulations.

Maintenance Tips

Regular maintenance includes [mention maintenance tasks], which help enhance longevity and optimize performance.

Warranty and Support

Warranty Coverage

The product is backed by [specify warranty details], providing peace of mind to customers.

Customer Support

Schneider Electric offers [describe customer support options], ensuring prompt assistance and technical guidance.

Conclusion

The Schneider C12N6TM125L exemplifies Schneider Electric’s commitment to delivering high-quality electrical solutions. With its advanced features, robust design, and suitability for various applications across industrial, commercial, and residential sectors, it remains a preferred choice for professionals seeking reliable electrical distribution and protection.

SKU: C12N6TM125L Category:
Main
RangeComPacT new generation
Product nameComPacT NSXm new generation
Range of productComPacT NSXm new generation
Device short nameNSXm 160N
product or component typeCircuit breaker
Device applicationDistribution
poles description4P
Protected poles description3D
Neutral positionLeft
[In] rated current125 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelN 50 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity90 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole9.64 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection terminals1 Everlink lug wire size 2.5…70 mm², flexible copper
1 Everlink lug wire size 2.5…95 mm², rigid or stranded copper
Connection pitch35 mm with spreaders
27 mm without spreaders
9 mm pitches12 module
Trip unit rating125 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
Neutral protection settingsNo protection (3D)
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range1250 A
Earth-leakage protectionWithout
Number of slots for electrical auxiliaries1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signallingFlag (green) for presence of auxiliary contacts
Width (W)108 mm
Height (H)137 mm
Depth (D)80 mm
net weight1.42 kg
ColourGrey (RAL 7016)
Environment
StandardsEN/IEC 60947
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height12 cm
Package 1 Width13 cm
Package 1 Length22 cm
Package 1 Weight1.6 kg
Unit Type of Package 2S03
Number of Units in Package 26
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight10.19 kg
Unit Type of Package 3P12
Number of Units in Package 3144
Package 3 Height150 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight254.49 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C12N6TM125L | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 125A, EverLink lugs”