-36%

Schneider C12N6TM160B | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 160A, lugs/busbars

Availability:

Out of stock


Schneider C12N6TM160B | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 160A, lugs/busbars

22,063 EGP 34,474 EGP

Out of stock

Compare

Schneider C12N6TM160B: A Comprehensive Guide

Introduction

it is a highly reliable and versatile electrical device from Schneider Electric, designed to meet the demanding needs of modern electrical systems. This article provides an in-depth look at its specifications, features, applications, installation guidelines, and maintenance tips.

Key Specifications

Power Rating and Voltage

it operates at a power rating of [specify power rating] and [voltage details], making it suitable for a wide array of electrical applications.

Dimensions and Design

The device boasts compact dimensions of [specify dimensions], ensuring it can be easily integrated into various installation environments while maintaining robust performance.

Environmental Considerations

Engineered to function efficiently in diverse environmental conditions, it offers excellent durability and reliability.

Features and Benefits

Advanced Protection Features

it is equipped with advanced protection mechanisms such as [list advanced protection features], providing enhanced safety for connected equipment and users.

High Efficiency

This device is designed for high efficiency, optimizing energy consumption and reducing operational costs through features like [highlight efficiency features].

User-Friendly Interface

Featuring an intuitive interface, it allows for easy operation and maintenance, with user-friendly controls and clear indicators.

Applications

Industrial Applications

In industrial settings, it excels in applications such as [list industrial applications], delivering reliable electrical distribution and protection.

Commercial Applications

For commercial environments, including [mention commercial settings], this device ensures efficient power management and robust safety features.

Residential Applications

Homeowners also benefit from the Schneider C12N6TM160B’s capabilities, providing safe and efficient electricity distribution for residential applications.

Installation and Maintenance

Installation Requirements

Installing the Schneider C12N6TM160B involves adhering to specific requirements such as [outline installation requirements], ensuring compliance with industry standards and safety protocols.

Maintenance Tips

To maintain optimal performance, regular maintenance tasks should be performed, including [mention maintenance tasks], which help prolong the device’s lifespan and reliability.

Warranty and Support

Warranty Coverage

The Schneider C12N6TM160B is backed by a comprehensive warranty of [specify warranty details], offering customers peace of mind.

Customer Support

Schneider Electric provides robust customer support, including [describe customer support options], ensuring prompt assistance and expert technical guidance.

Conclusion

The Schneider C12N6TM160B stands out as a reliable and efficient solution for various electrical applications. Its advanced features, robust design, and versatility across industrial, commercial, and residential sectors make it a top choice for professionals seeking dependable electrical distribution and protection.

SKU: C12N6TM160B Category: Brand:
Main
RangeComPacT new generation
Product nameComPacT NSXm new generation
Range of productComPacT NSXm new generation
Device short nameNSXm 160N
product or component typeCircuit breaker
Device applicationDistribution
poles description4P
Protected poles description3D
Neutral positionLeft
[In] rated current160 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelN 50 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity90 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole12.21 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection terminalsCompression lug/busbar
Connection pitch35 mm with spreaders
27 mm without spreaders
9 mm pitches12 module
Trip unit rating160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
Neutral protection settingsNo protection (3D)
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range1250 A
Earth-leakage protectionWithout
Number of slots for electrical auxiliaries1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signallingFlag (green) for presence of auxiliary contacts
Width (W)108 mm
Height (H)137 mm
Depth (D)80 mm
net weight1.42 kg
ColourGrey (RAL 7016)
Environment
StandardsEN/IEC 60947
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height13.000 cm
Package 1 Width12.000 cm
Package 1 Length22.000 cm
Package 1 Weight1.600 kg
Unit Type of Package 2S03
Number of Units in Package 26
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight10.190 kg
Unit Type of Package 3P12
Number of Units in Package 3144
Package 3 Height150.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight254.490 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C12N6TM160B | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 160A, lugs/busbars”