Let's Chat
-34%
,

Schneider C16F3TM160 | Circuit breaker, ComPacT NSX160F, 36kA/415VAC, 3 poles, TMD trip unit 160A

Availability:

Out of stock


Schneider C16F3TM160 | Circuit breaker, ComPacT NSX160F, 36kA/415VAC, 3 poles, TMD trip unit 160A

15,642 EGP 23,701 EGP

Out of stock

Compare

Schneider C16F3TM160 | Circuit breaker, ComPacT NSX160F, 36kA/415VAC, 3 poles, TMD trip unit 160A

Schneider C16F3TM160 Description

Introduction

Schneider Electric is a global leader in energy management and automation solutions, renowned for its high-quality products and innovative designs. Among its extensive product line, it stands out as a critical component for circuit protection. This article explores the features, applications, and benefits of it, providing a comprehensive overview of its capabilities.

Company Background

History and Evolution of Schneider Electric

Founded in 1836, Schneider Electric has grown to become a global leader in energy management and automation. With a strong commitment to innovation, Schneider Electric consistently delivers products that meet the highest standards of quality and reliability.

Commitment to Innovation and Quality

Schneider Electric’s dedication to innovation is evident in its extensive research and development efforts. The C16F3TM160 exemplifies this commitment, offering advanced features designed to enhance circuit protection and efficiency.

Product Introduction

Introduction to the Schneider C16F3TM160

it is a circuit breaker designed to safeguard electrical circuits from overloads and short circuits. Its robust design and reliable performance make it an essential component in various industrial and commercial applications.

Key Features and Benefits

  • Reliable Protection: Provides comprehensive protection against overloads and short circuits.
  • Compact Design: Space-saving design allows for easy integration into control panels.
  • Easy Installation: User-friendly features ensure quick and straightforward installation.
  • Durable Construction: Built to withstand harsh industrial environments.

These features make the C16F3TM160 a reliable and efficient solution for circuit protection.

Technical Specifications

Electrical Ratings and Capabilities

it is designed to operate within specific electrical parameters, ensuring optimal performance and protection. Key specifications include:

  • Rated Operational Voltage: 415V AC
  • Rated Operational Current: Up to 160A
  • Breaking Capacity: High breaking capacity for effective short-circuit protection

Physical Dimensions and Weight

The compact and lightweight design of it facilitates easy installation and integration into various systems. Its ergonomic design ensures minimal space usage while maintaining high functionality.

Applications

Industrial Applications

The C16F3TM160 is widely used in manufacturing plants, distribution panels, and other industrial settings to protect circuits and ensure safe operations. Its durability and reliable performance make it suitable for demanding industrial environments.

Commercial Applications

In commercial settings, the C16F3TM160 is employed to protect electrical circuits in buildings, data centers, and other critical applications. Its versatility and robust design ensure reliable protection across a range of applications.

Installation and Setup

Step-by-Step Installation Guide

To install the Schneider C16F3TM160, follow these steps:

  1. Preparation: Gather all necessary components and tools.
  2. Mounting: Secure the C16F3TM160 in the desired location using appropriate mounting hardware.
  3. Wiring: Connect the electrical wires as per the provided schematic diagram.
  4. Testing: Conduct initial tests to ensure proper functionality.

Safety Precautions

Ensure to follow all safety guidelines during installation, including using personal protective equipment (PPE) and adhering to electrical safety standards.

Maintenance

Routine Maintenance Tips

To maintain the optimal performance of the C16F3TM160:

  • Regular Inspections: Check for wear and tear or any signs of damage.
  • Cleaning: Keep the device clean from dust and debris.
  • Servicing: Schedule periodic servicing to ensure continued reliability.

Troubleshooting Guide

For troubleshooting, refer to the user manual or contact Schneider Electric’s technical support to address any operational issues effectively.

Performance and Efficiency

Efficiency Analysis

The Schneider C16F3TM160 is designed to deliver high efficiency, providing reliable performance while minimizing energy consumption. Its precision and durability ensure long-term operational efficiency.

User Testimonials and Feedback

Users commend the C16F3TM160 for its robustness and accuracy. Testimonials highlight its ease of installation and reliable performance in various industrial and commercial applications.

Comparisons

Comparison with Similar Schneider Electric Products

Compared to other Schneider Electric circuit breakers, the C16F3TM160 offers advanced features and superior construction, making it a preferred choice for critical applications.

Competitor Analysis

The C16F3TM160 stands out among competitor products due to its durability, precision, and ease of installation. Its competitive pricing and robust performance further enhance its market appeal.

Sustainability

Environmental Considerations

Schneider Electric incorporates eco-friendly materials and technologies in the C16F3TM160, reducing its environmental impact and supporting sustainability initiatives.

Schneider Electric’s Sustainable Practices

Schneider Electric is committed to sustainable practices, including reducing waste, conserving energy, and using recyclable materials in its products.

SKU: C16F3TM160 Categories: ,
brands

Schneider Electric

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX160F
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 160 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 480 V AC 50/60 Hz conforming to UL 508
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 40000 cycles
Electrical durability 40000 cycles at 440 V In/2
20000 cycles at 440 V In
15000 cycles at 690 V In/2
7500 cycles at 690 V In
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1250 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.2 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.0 cm
Package 1 Width 11.5 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.83 kg
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 13.198 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C16F3TM160 | Circuit breaker, ComPacT NSX160F, 36kA/415VAC, 3 poles, TMD trip unit 160A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024