1. Technical Specifications of Schneider C25F6TM250

  • Model: ComPacT NSX250F
  • Breaking Capacity: 36kA at 415VAC
  • Number of Poles: 4 (3 protected poles + neutral not protected)
  • Trip Unit: TMD (Thermal-Magnetic)
  • Rated Current: 250A
  • Circuit Breaker Type: Molded Case Circuit Breaker (MCCB)
  • Operational Voltage: Up to 690VAC
  • Frequency: 50/60Hz

2. Features:

High Performance & Reliability: Ensures effective protection against overloads and short circuits.
Compact Design: Ideal for space-constrained installations.
Advanced Protection: Equipped with a thermal-magnetic trip unit for enhanced safety.
Easy Installation: Designed for quick and secure panel mounting.
Efficient Power Distribution: Ensures stable electrical system operation.
Long Service Life: Built to withstand numerous switching operations.

3. Applications:

Commercial & Industrial Buildings: Protects distribution panels from excessive loads.
Electrical Facilities: Suitable for power generation and distribution systems.
Motor Control: Provides reliable protection for large motors and electrical equipment.
Renewable Energy Systems: Can be integrated into solar power and modern energy grids

brands

Main
RangeComPacT new generation
product nameComPacT NSX new generation
Device short nameNSX250F
Product or component typeCircuit breaker
Device applicationDistribution
Poles description4P
Protected poles description3D
Neutral positionLeft
[In] rated current250 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 480 V AC 50/60 Hz conforming to UL 508
15 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance levelF 36 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole18.75 W
Mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
Downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating250 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range120…400 s at 1.5 x In
15 s at 6 x Ir
Neutral protection settingsNo protection (3D)
Instantaneous protection pick-up adjustment type IiAdjustable
[Ii] instantaneous protection pick-up adjustment range5…10 x In
Earth-leakage protectionWithout
Number of slots for electrical auxiliaries5 slot(s)
Width (W)140 mm
Height (H)161 mm
Depth (D)86 mm
Product weight2.8 kg
Environment
StandardsEN/IEC 60947-2
overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.400 cm
Package 1 Width14.700 cm
Package 1 Length19.600 cm
Package 1 Weight2.628 kg
Unit Type of Package 2S03
Number of Units in Package 23
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.264 kg

Main Document

Data Sheet : Download