-34%
, , ,

Schneider C25H42D250 | Circuit breaker ComPacT NSX250H, 70kA at 415VAC, MicroLogic 2.2 trip unit 250A, 4 poles 4d

Schneider Electric
Availability:

Out of stock


Schneider C25H42D250 | Circuit breaker ComPacT NSX250H, 70kA at 415VAC, MicroLogic 2.2 trip unit 250A, 4 poles 4d

42,601 EGP 64,547 EGP

Out of stock

Compare

Schneider C25H42D250 | Circuit breaker ComPacT NSX250H, 70kA at 415VAC, MicroLogic 2.2 trip unit 250A, 4 poles 4d

Schneider C25H42D250 | ComPacT NSX250H Circuit Breaker

1. Technical Specifications of Schneider C25H42D250

  • Model: ComPacT NSX250H
  • Breaking Capacity: 70kA at 415VAC
  • Number of Poles: 4 (4 protected poles)
  • Trip Unit: MicroLogic 2.2
  • Rated Current: 250A
  • Circuit Breaker Type: Molded Case Circuit Breaker (MCCB)
  • Operational Voltage: Up to 690VAC
  • Frequency: 50/60Hz

2. Features of Schneider C25H42D250

High Breaking Capacity: 70kA ensures excellent protection against short circuits.
Advanced Trip Unit: MicroLogic 2.2 provides enhanced monitoring and protection.
Full Protection: All 4 poles are protected for complete electrical safety.
Compact & Durable Design: Ideal for demanding applications with limited space.
Easy Installation & Maintenance: Designed for quick integration into electrical panels.
Optimized Energy Management: Ensures efficient power distribution and system stability.

3. Applications:

🔹 Industrial & Commercial Buildings: Protects electrical distribution networks from overloads and faults.
🔹 Data Centers & Critical Infrastructure: Ensures stable power supply and fault isolation.
🔹 Power Plants & Renewable Energy Systems: Suitable for solar, wind, and industrial power grids.
🔹 Heavy-Duty Motor Control: Provides reliable protection for high-power motors and machinery.

brands

Main
RangeComPacT new generation
product nameComPacT NSX new generation
Device short nameNSX250H
Product or component typeCircuit breaker
Device applicationDistribution
Poles description4P
Protected poles description4D
3D + N/2
3D + N/2
Neutral positionLeft
[In] rated current250 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance levelH 70 kA 415 V AC
Trip unit nameMicroLogic 2.2
Trip unit technologyElectronic
Trip unit protection functionsLSoI
control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole17.6 W
Mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
Downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating250 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range100…250 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range400 s at 1.5 x Ir
16 s at 6 x Ir
11 s at 7.2 x Ir
Neutral protection settings0.5 x Ir (3D + N/2)
1 x Ir (4D)
No protection (3D)
Thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5…10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range3000 A
Earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries5 slot(s)
Local signallingFlashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W)140 mm
Height (H)161 mm
Depth (D)86 mm
Product weight2.8 kg
Environment
StandardsEN/IEC 60947-2
overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.000 cm
Package 1 Width14.500 cm
Package 1 Length19.000 cm
Package 1 Weight2.606 kg
Unit Type of Package 2S03
Number of Units in Package 24
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight10.802 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C25H42D250 | Circuit breaker ComPacT NSX250H, 70kA at 415VAC, MicroLogic 2.2 trip unit 250A, 4 poles 4d”

There are no reviews yet.

SHOPPING CART