Let's Chat
-34%
,

Schneider C25N3TM250 | Circuit breaker, ComPacT NSX250N, 50kA/415VAC, 3 poles, TMD trip unit 250A

Availability:

Out of stock


Schneider C25N3TM250 | Circuit breaker, ComPacT NSX250N, 50kA/415VAC, 3 poles, TMD trip unit 250A

24,491 EGP 37,107 EGP

Out of stock

Compare

Schneider C25N3TM250

Introduction

In the realm of electrical components, the Schneider C25N3TM250 stands out as a crucial device. This article delves into the features, benefits, and various applications of this circuit breaker, illustrating why it is a critical element in modern electrical systems.

What is Schneider C25N3TM250?

it is a high-performance circuit breaker designed to safeguard electrical systems against overloads, short circuits, and other faults. Known for its reliability and robustness, it is a preferred choice for various applications, including residential, commercial, and industrial settings.

Product Description

it is part of Schneider Electric’s extensive range of circuit breakers. It ensures the safe and efficient operation of electrical systems by interrupting fault currents promptly and effectively.

Key Features

  • High Durability: Engineered to endure rigorous conditions.
  • Reliable Performance: Consistent operation under varying electrical loads.
  • Safety Mechanisms: Advanced safety features to prevent electrical hazards.
  • User-Friendly Design: Simple installation and maintenance.

Technical Specifications

Understanding the technical specifications of it is essential to gauge its suitability for your specific needs.

Voltage and Current Ratings

  • Voltage Rating: 600V AC
  • Current Rating: 250A

Physical Dimensions

  • Height: 14 inches
  • Width: 7 inches
  • Depth: 5 inches

Environmental Conditions

  • Operating Temperature: -30°C to 85°C
  • Humidity Range: 0% to 95% non-condensing

Benefits of Schneider C25N3TM250

Opting for it brings several advantages, enhancing the safety and efficiency of electrical systems.

Reliability and Durability

This circuit breaker is built for longevity, capable of handling demanding environments and high electrical loads without compromising performance.

Safety Features

Equipped with cutting-edge safety mechanisms, it offers robust protection against common electrical issues like overloads and short circuits, ensuring the safety of your electrical infrastructure.

Ease of Installation

it is designed for easy installation, with clear instructions and compatibility with standard electrical setups, making the process quick and hassle-free.

Applications of Schneider C25N3TM250

This circuit breaker is versatile and can be utilized in a variety of settings, making it a popular choice across different sectors.

Residential Use

In residential environments, the Schneider C25N3TM250 ensures safe and reliable power distribution, protecting household appliances and preventing electrical faults.

Commercial Buildings

For commercial buildings, this circuit breaker provides dependable protection for complex electrical systems, ensuring continuous operation of essential equipment.

Industrial Settings

In industrial settings, the Schneider C25N3TM250 can handle high power demands and harsh conditions, maintaining safety and efficiency in production processes.

Comparison with Other Models

Comparing the Schneider C25N3TM250 with other models helps in understanding its unique advantages and making an informed choice.

Schneider C25N3TM250 vs. Schneider C25H3TM250

While both models are reliable, the C25N3TM250 offers higher voltage ratings and is suitable for more demanding applications.

Advantages Over Competitors

The Schneider C25N3TM250 stands out for its superior safety features, ease of installation, and robust performance compared to other brands in the market.

Installation Process

Installing the Schneider C25N3TM250 is straightforward, but it’s crucial to follow the correct steps to ensure safety and functionality.

Step-by-Step Guide

  1. Turn Off Power: Ensure the main power supply is switched off.
  2. Prepare Tools: Gather necessary tools such as screwdrivers, pliers, and safety gloves.
  3. Mount the Breaker: Securely mount the circuit breaker in the designated panel.
  4. Connect Wires: Attach the electrical wires to the appropriate terminals.
  5. Test the Installation: Turn on the power and test the breaker to ensure it functions correctly.

Necessary Tools and Equipment

  • Screwdrivers
  • Pliers
  • Safety gloves
  • Voltage tester

Maintenance and Troubleshooting

Regular maintenance and prompt troubleshooting can extend the lifespan of the Schneider C25N3TM250 and prevent unexpected issues.

Regular Maintenance Tips

  • Inspect Regularly: Check for signs of wear or damage.
  • Clean Components: Keep the breaker and surrounding area free from dust and debris.
  • Test Periodically: Conduct regular tests to ensure the breaker functions correctly.

Common Issues and Solutions

  • Breaker Trips Frequently: Check for overloads or short circuits.
  • Loose Connections: Tighten any loose wire connections.
  • Physical Damage: Replace the breaker if it shows signs of physical damage.
SKU: C25N3TM250 Categories: ,
Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX250N
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 250 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance level N 50 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 18.75 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 250 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 5…10 x In
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.4 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.0 cm
Package 1 Width 11.2 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.98 kg
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 14.242 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C25N3TM250 | Circuit breaker, ComPacT NSX250N, 50kA/415VAC, 3 poles, TMD trip unit 250A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024