Schneider C63F32D630: Detailed Product Overview

Introduction

The Schneider C63F32D630 is a high-capacity molded case circuit breaker (MCCB) designed for demanding applications that require robust protection and efficient power management. With a 630A current rating, this circuit breaker is engineered to handle large electrical loads, providing both overload and short-circuit protection through Schneider’s advanced thermal-magnetic trip technology. Ideal for industrial, commercial, and utility applications, the C63F32D630 offers a dependable solution for ensuring safety and operational continuity.

Key Features of Schneider C63F32D630

  • 630A Rated Current: Suited for high-load applications, ensuring reliable protection for circuits carrying substantial electrical power.
  • Thermal-Magnetic Trip Mechanism: Combines thermal overload protection with magnetic short-circuit response, providing accurate and efficient fault detection.
  • High Breaking Capacity: Equipped to handle high fault currents, making it suitable for applications with large electrical demands.
  • Compact and Sturdy Design: Optimized for standard panel installations while maintaining the durability required for high-capacity use.
  • Adjustable Trip Settings: Offers customizable trip levels, allowing the circuit breaker to be adapted to specific application requirements.

Applications of Schneider C63F32D630

  1. Industrial Manufacturing Plants: Protects high-power machinery and equipment, minimizing downtime and ensuring safe operation.
  2. Commercial Buildings and Complexes: Provides essential protection for building power systems, such as HVAC, lighting, and electrical distribution.
  3. Data Centers and IT Infrastructure: Ensures reliable power for critical IT equipment and server rooms, helping prevent costly disruptions.
  4. Renewable Energy Installations: Suitable for solar and wind power systems, offering protection against power surges and fluctuations.
  5. Utility Networks and Substations: Designed to protect electrical infrastructure in substations, ensuring safe and stable power distribution.

Benefits of Using Schneider C63F32D630

  • High-Performance Protection for Heavy Loads: The 630A rating ensures robust protection for demanding applications with significant power requirements.
  • Fast and Accurate Fault Response: The thermal-magnetic trip unit provides quick and reliable protection against both overloads and short circuits.
  • Adaptable to Various Systems: Adjustable settings allow for tailored protection, making it flexible across diverse applications.
  • Space-Saving Design: The compact structure enables efficient panel layout without compromising on durability.
  • Reduced Maintenance Needs: Built to Schneider’s high standards for durability, this MCCB requires minimal upkeep, ensuring cost-effectiveness over time.
SKU: C63F32D630 Categories: ,
Main
RangeComPacT new generation
Product nameComPacT NSX new generation
Device short nameNSX630F
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3D
[In] rated current630 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance levelF 36 kA 415 V AC
Trip unit nameMicroLogic 2.3
Trip unit technologyElectronic
Trip unit protection functionsLSoI
control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability15000 cycles
Electrical durability8000 cycles at 440 V In/2
4000 cycles at 440 V In
6000 cycles at 690 V In/2
2000 cycles at 690 V In
Power dissipation per pole39.69 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch45 mm
Protection typeL : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating630 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range250…630 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range400 s at 1.5 x Ir
16 s at 6 x Ir
11 s at 7.2 x Ir
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5…10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range6900 A
earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries6 slot(s)
Local signallingFlashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W)140 mm
Height (H)255 mm
Depth (D)110 mm
Net weight6.2 kg
Environment
StandardsEN/IEC 60947
product certificationsCCC
EAC
Marine
Overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.0 cm
Package 1 Width15.5 cm
Package 1 Length29.0 cm
Package 1 Weight5.728 kg
Unit Type of Package 2S04
Number of Units in Package 22
Package 2 Height30.0 cm
Package 2 Width40.0 cm
Package 2 Length60.0 cm
Package 2 Weight12.308 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C63F32D630 | Circuit breaker, ComPacT NSX630F, 36kA/415VAC, 3 poles, MicroLogic 2.3 trip unit 630A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat