Schneider C63H42D630: Comprehensive Product Guide

Introduction

The Schneider C63H42D630 is a high-capacity molded case circuit breaker (MCCB) designed to deliver exceptional protection for heavy-duty electrical systems. With a robust 630A rating, it’s well-suited for applications that demand dependable circuit protection and power management in industrial, commercial, and infrastructure settings. This model combines Schneider’s proven thermal-magnetic trip technology for efficient overload and short-circuit protection, making it a solid choice for high-demand environments where reliability is critical.

Key Features of Schneider C63H42D630

  • 630A Rated Current: Provides protection for high-capacity circuits, ensuring safe and reliable operations in power-intensive environments.
  • Thermal-Magnetic Trip Unit: Dual-mode protection combines thermal response for gradual overloads with magnetic response for instant short-circuit faults.
  • High Breaking Capacity: Designed to interrupt substantial fault currents, protecting both equipment and users in high-load applications.
  • Compact Design for Panel Efficiency: Optimized for easy installation in panels without occupying excessive space, making it ideal for densely packed systems.
  • Customizable Trip Settings: Allows for tailored protection by adjusting trip settings, providing flexibility for varied electrical setups.

Applications of Schneider C63H42D630

  1. Heavy Industrial Equipment and Machinery: Provides essential protection for motors, pumps, compressors, and other high-power equipment.
  2. Large Commercial Buildings: Ensures safe and efficient power distribution for HVAC systems, lighting, elevators, and other major electrical loads.
  3. Data Centers and Telecommunications: Offers reliable protection for power-critical IT infrastructure, minimizing the risk of power interruptions.
  4. Renewable Energy Installations: Works effectively with solar, wind, and other renewable systems to protect against power surges and load variations.
  5. Utility and Infrastructure Systems: Protects substations and utility networks, enhancing the reliability and safety of power distribution.

Benefits of Using Schneider C63H42D630

  • Enhanced Safety for High-Capacity Systems: The 630A rating delivers dependable protection in environments with large electrical demands.
  • Fast, Accurate Fault Detection: The thermal-magnetic trip technology provides immediate response to short circuits and overloads.
  • Adaptability Across Applications: Adjustable trip settings allow for customization to specific system requirements, improving both performance and safety.
  • Efficient Use of Space: Compact and sturdy design fits efficiently in panels, maximizing available space for other essential equipment.
  • Low Maintenance Requirements: Built with Schneider’s commitment to quality, this MCCB is durable and requires minimal maintenance over time.
SKU: C63H42D630 Category:
Main
RangeComPacT new generation
Product nameComPacT NSX new generation
Device short nameNSX630H
Product or component typeCircuit breaker
Device applicationDistribution
poles description4P
Protected poles description4D
3D + N/2
3D
Neutral positionLeft
[In] rated current630 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance levelH 70 kA 415 V AC
Trip unit nameMicroLogic 2.3
Trip unit technologyElectronic
Trip unit protection functionsLSoI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability15000 cycles
Electrical durability8000 cycles at 440 V In/2
4000 cycles at 440 V In
6000 cycles at 690 V In/2
2000 cycles at 690 V In
Power dissipation per pole39.69 W
Mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch45 mm
Protection typeL : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating630 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range250…630 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range400 s at 1.5 x Ir
16 s at 6 x Ir
11 s at 7.2 x Ir
Neutral protection settings0.5 x Ir (3D + N/2)
1 x Ir (4D)
No protection (3D)
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5…10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range6900 A
Earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries6 slot(s)
Local signallingFlashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W)185 mm
Height (H)255 mm
Depth (D)110 mm
Net weight8.13 kg
Environment
StandardsEN/IEC 60947-2
Overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.0 cm
Package 1 Width20.4 cm
Package 1 Length29.0 cm
Package 1 Weight7.542 kg
Unit Type of Package 2S04
Number of Units in Package 22
Package 2 Height30.0 cm
Package 2 Width40.0 cm
Package 2 Length60.0 cm
Package 2 Weight16.0 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C63H42D630 | Circuit breaker ComPacT NSX630H, 70kA at 415VAC, MicroLogic 2.3 trip unit 630A, 4 poles 4d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat