Schneider C63N32D630: Complete Product Overview

Introduction

The Schneider C63N32D630 is a high-performance molded case circuit breaker (MCCB) designed for heavy-duty applications that require reliable protection against electrical faults. With a 630A rating, this MCCB is ideal for large-scale industrial, commercial, and utility systems where significant electrical loads are handled. The C63N32D630 uses Schneider’s advanced thermal-magnetic trip technology to offer dual protection against overloads and short circuits, making it an essential component for ensuring the safety and reliability of electrical installations.

Key Features of Schneider C63N32D630

  • 630A Current Rating: Provides superior protection for circuits with high current demands, ideal for industrial and commercial applications.
  • Thermal-Magnetic Trip Mechanism: Combines both thermal protection for overloads and magnetic protection for instantaneous short-circuit response.
  • High Breaking Capacity: Designed to safely interrupt high fault currents, preventing potential damage to equipment and infrastructure.
  • Compact Design: Despite its powerful capabilities, the C63N32D630 is designed to be space-efficient, easily fitting into standard electrical panels.
  • Adjustable Trip Settings: Offers customizable settings for both thermal and magnetic trip characteristics, allowing flexibility for different systems.

Applications of Schneider C63N32D630

  1. Industrial Power Distribution: Protects high-capacity industrial equipment such as motors, transformers, and compressors, ensuring consistent operation.
  2. Commercial and Institutional Buildings: Ideal for protecting electrical distribution systems in large office buildings, shopping centers, and healthcare facilities.
  3. Renewable Energy Systems: Suitable for use in solar power, wind, and other renewable energy installations, where load fluctuations and fault protection are essential.
  4. Data Centers and IT Networks: Provides protection for critical IT infrastructure by safeguarding power distribution systems against overloads and short circuits.
  5. Utility Networks and Substations: Works in utility applications to protect power distribution networks, ensuring reliable service and preventing disruptions.

Benefits of Schneider C63N32D630

  • Robust Protection for Heavy Loads: The 630A rating is designed for high-power systems, ensuring protection in demanding environments where large electrical loads are present.
  • Dual Protection Mechanism: The thermal-magnetic trip unit offers comprehensive protection, responding quickly to both short circuits and overload conditions.
  • Customizable Settings: The adjustable trip settings allow for tailored protection to meet specific system requirements, enhancing flexibility.
  • Space-Efficient Design: Its compact size makes it suitable for crowded panels without compromising on performance or safety.
  • Durable and Low-Maintenance: Designed with longevity in mind, the C63N32D630 requires minimal maintenance, providing long-term, reliable protection.

 

SKU: C63N32D630 Categories: , Brand:
Main
RangeComPacT new generation
Product nameComPacT NSX new generation
Device short nameNSX630N
Product or component typeeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3D
[In] rated current630 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 480 V AC 50/60 Hz conforming to UL 508
Performance levelN 50 kA 415 V AC
Trip unit nameMicroLogic 2.3
Trip unit technologyElectronic
Trip unit protection functionsLSoI
control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability15000 cycles
Electrical durability8000 cycles at 440 V In/2
4000 cycles at 440 V In
6000 cycles at 690 V In/2
2000 cycles at 690 V In
Power dissipation per pole39.69 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch45 mm
Protection typeL : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating630 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range250…630 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range400 s at 1.5 x Ir
16 s at 6 x Ir
11 s at 7.2 x Ir
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5…10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range6900 A
earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries6 slot(s)
Local signallingFlashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W)140 mm
Height (H)255 mm
Depth (D)110 mm
Net weight6.2 kg
Environment
StandardsEN/IEC 60947
product certificationsCCC
EAC
Marine
Overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.0 cm
Package 1 Width16.0 cm
Package 1 Length29.5 cm
Package 1 Weight5.732 kg
Unit Type of Package 2S04
Number of Units in Package 22
Package 2 Height30.0 cm
Package 2 Width40.0 cm
Package 2 Length60.0 cm
Package 2 Weight12.318 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C63N32D630 | Circuit breaker, ComPacT NSX630N, 50kA/415VAC, 3 poles, MicroLogic 2.3 trip unit 630A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat