In today’s world, where industrial automation is becoming increasingly prevalent, having the right control equipment is crucial. One such essential component is the Schneider CAD50M7. This article will delve into its description, features, benefits, installation process, troubleshooting, and maintenance tips to help you understand its importance and functionality better.

Introduction to Schneider CAD50M7

it is a versatile control relay module designed to provide reliable performance in various industrial applications. With its robust construction and advanced features, it offers a seamless solution for controlling electrical circuits in automation systems.

Overview of CAD50M7 Features

General Description

it control relay module is engineered to deliver exceptional performance in demanding environments. Its compact design makes it suitable for installation in confined spaces, while its durable construction ensures long-term reliability.

Technical Specifications

  • Voltage Rating: 24V DC
  • Contact Configuration: 4PST-NO (4 Normally Open Contacts)
  • Coil Voltage Range: 20.4V to 26.4V DC
  • Operating Temperature: -25°C to +55°C
  • Mounting: DIN Rail Mountable
  • Certifications: CE, UL Listed

Applications

it finds applications in various industrial sectors, including manufacturing, automotive, pharmaceuticals, and food processing. It is commonly used for controlling motors, pumps, solenoid valves, and lighting systems in automated machinery.

Benefits of Using

  • Reliability: With its robust design and high-quality components, it ensures reliable operation even in harsh industrial environments.
  • Versatility: It can be easily integrated into different automation systems, offering flexibility and adaptability.
  • Safety: The module adheres to strict safety standards, providing protection against overloads, short circuits, and voltage fluctuations.
  • Efficiency: CAD50M7 enhances operational efficiency by streamlining control processes and reducing downtime.

How to Install

Installing it is a straightforward process that can be completed in a few simple steps:

  1. Select Mounting Location: Choose a suitable location on the DIN rail for mounting the CAD50M7 module.
  2. Connect Power Supply: Ensure that the power supply is disconnected before wiring the module. Connect the positive and negative terminals of the power supply to the respective terminals on the module.
  3. Wire Control Devices: Connect the control devices, such as switches or sensors, to the input terminals of the module.
  4. Connect Load: Wire the load, such as a motor or a solenoid valve, to the output terminals of the module.
  5. Secure Connections: Double-check all connections to ensure they are secure and properly insulated.
  6. Power Up: Once the installation is complete, reconnect the power supply and test the operation of the CAD50M7 module.

Troubleshooting Common Issues

Despite its reliable performance, CAD50M7 may encounter occasional issues. Here are some common problems and their troubleshooting steps:

  1. No Power Output: Check the power supply and ensure that it is within the specified voltage range. Verify the connections and look for any loose or damaged wires.
  2. Faulty Contacts: Inspect the relay contacts for any signs of damage or wear. Clean the contacts if necessary and replace any faulty components.
  3. Overheating: Ensure proper ventilation around the module to prevent overheating. Check for any obstructions or debris blocking the airflow.
  4. Intermittent Operation: Check for loose connections or poor wiring. Tighten any loose terminals and recheck the connections.
  5. Error Codes: Refer to the user manual for troubleshooting guidance specific to error codes or fault indicators.

Maintenance Tips for CAD50M7

To ensure optimal performance and longevity of the CAD50M7 module, follow these maintenance tips:

  • Regular Inspections: Periodically inspect the module for signs of damage, corrosion, or overheating.
  • Cleanliness: Keep the surrounding area clean and free from dust and debris to prevent obstruction of ventilation.
  • Tighten Connections: Check all terminal connections regularly and tighten them if necessary to prevent loose connections.
  • Update Firmware: If applicable, keep the firmware of the module up to date to ensure compatibility with the latest automation systems.

Conclusion

In conclusion, Schneider CAD50M7 is a reliable and versatile control relay module that offers seamless integration into industrial automation systems. With its advanced features, robust construction, and easy installation, it provides efficient control solutions for various applications. By following proper installation, troubleshooting, and maintenance practices, users can ensure optimal performance and longevity of the CAD50M7 module in their automation setups.

Main
Range TeSys
TeSys Deca
Product name TeSys CAD
Product or component type Control relay
Device short name CAD
Contactor application Control circuit
Complementary
Utilisation category AC-15
AC-14
DC-13
Pole contact composition 5 NO
[Ue] rated operational voltage <= 690 V AC 25…400 Hz
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 220 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
[Ith] conventional free air thermal current 10 A (at 60 °C)
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current 100 A – 1 s
120 A – 500 ms
140 A – 100 ms
Associated fuse rating 10 A gG conforming to IEC 60947-5-1
[Ui] rated insulation voltage 600 V UL certified
600 V CSA certified
690 V conforming to IEC 60947-5-1
Mounting support Plate
Rail
Connections – terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Tightening torque 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Operating time 12…22 ms coil energisation and NO closing
4…12 ms coil de-energisation and NO opening
Mechanical durability 30 Mcycles
Maximum operating rate 180 cyc/mn
Inrush power in VA 70 VA 50 Hz (at 20 °C)
Hold-in power consumption in VA 8 VA 50 Hz (at 20 °C)
Minimum switching voltage 17 V
Minimum switching current 5 mA
Non-overlap time 1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contact
Insulation resistance > 10 MOhm
Mechanical robustness Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations control relay open: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations control relay closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Height 77 mm
Width 45 mm
Depth 84 mm
Product weight 0.58 kg
Environment
Standards EN/IEC 60947-5-1
GB/T 14048.5
UL 60947-5-1
CSA C22.2 No 60947-5-1
JIS C8201-5-1
Product certifications CB
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protection IP2X front face conforming to VDE 0106
Protective treatment TH conforming to IEC 60068
Ambient air temperature for operation -40…60 °C
60…70 °C with derating
Ambient air temperature for storage -60…80 °C
Operating altitude 0…3000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.500 cm
Package 1 Width 8.200 cm
Package 1 Length 9.500 cm
Package 1 Weight 352.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 20
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 7.359 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet CAD50M7
Instruction sheet
Download
Catalogue
Download
CAD Files
Download
Environmental disclosure Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider CAD50M7 | TeSys D control relay – 5 NO – <= 690 V – 220 V AC standard coil”

There are no reviews yet.

SHOPPING CART

close
Let's Chat