-46%

Schneider EOCRSE2-30NS | electronic overcurrent relay – 0.5..6 A – 220 V AC

Schneider Electric
Availability:

In stock


Schneider EOCRSE2-30NS | electronic overcurrent relay – 0.5..6 A – 220 V AC

1,975 EGP 3,657 EGP

In stock

Compare

Schneider EOCRSE2-30NS: Comprehensive Overview

Introduction

it is an advanced electronic overload relay engineered for superior motor protection. With its intelligent design and reliable performance, this relay is suitable for a variety of industrial applications, ensuring optimal motor operation and protection against overload, phase failure, and other electrical faults.

Technical Specifications

  • Model Number: EOCRSE2-30NS
  • Protection Type: Electronic overload relay
  • Rated Current Range: 0.5 to 30A (adjustable)
  • Voltage: Compatible with standard industrial voltage ranges
  • Mounting Type: DIN rail or panel-mounted
  • Trip Class: Class 10A, 10, 20, or 30 (configurable)
  • Phase Protection: Protects against phase loss, phase unbalance, and reverse phase sequence
  • Communication Capabilities: Supports advanced connectivity for remote monitoring and control (if applicable)

Key Features

  1. Wide Current Range:
    • Adjustable current settings from 0.5 to 30A allow flexibility for various motor sizes.
  2. Multi-Functional Protection:
    • Provides overload, phase loss, and phase unbalance protection.
    • Configurable trip class for application-specific needs.
  3. Compact and Durable Design:
    • Fits seamlessly into compact control panels while offering robust performance.
  4. User-Friendly Operation:
    • Equipped with intuitive settings and LED indicators for easy monitoring and adjustments.
  5. Energy-Efficient and Reliable:
    • Minimizes downtime and ensures efficient motor operation by detecting faults early.

Applications

it is ideal for use in:

  • Industrial Motor Control Panels: Ensures reliable motor protection in manufacturing environments.
  • Pumps and Compressors: Safeguards against overload and operational faults.
  • HVAC Systems: Protects motors in heating, ventilation, and air-conditioning systems.
  • Conveyors and Material Handling Systems: Provides consistent motor protection for smooth operations.

Benefits

  • Enhanced Motor Longevity: Reduces wear and tear on motors by preventing electrical faults.
  • Improved System Safety: Protects against critical faults like phase loss and unbalance.
  • Cost-Effective Maintenance: Minimizes downtime and repair costs through early fault detection.
  • Flexible Integration: Fits a range of control panel designs with its compact size and adjustable settings.
SKU: EOCRSE2-30NS Category: Brand:
Main
range of productEOCR
Device short nameEOCR-3D420
Product or component typeeProtection relay
Protection typeOverload, In > OC setting
Sensitivity to phase loss
Sensitivity to phase reverse
Locked rotor, In > 3 times OC setting
Phase unbalance, 50 %
Product specific applicationOvercurrent protection
Analogue output range4…20 mA
Network typeAC
Network frequency50…60 Hz
protection ajustment range0.5…10 A
Tripping threshold0.5…6 A
Complementary
[Us] rated supply voltage220 V AC
Mounting support35 mm DIN rail
Panel
Contacts type and composition1 NO + 1 NC (OL)
Short-circuit and overload protectionBy 4 A gG fuse
[Ue] rated operational voltage600 V AC 50…60 Hz for power circuit conforming to UL
690 V AC 50…60 Hz for power circuit conforming to CSA
690 V AC 50…60 Hz for power circuit conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-4-1
ResetManual reset
Electrical 0…1 s by interruption of power supply
Time delay typeO-Time: 0.3, 1…30 s, off (definite)
D-Time: 1…120 s, off (definite)
O-Time: 1…30 class (inverse)
D-Time: 0…120 s (inverse)
Display type7 segments LED
power consumption per relay3 W
Connections – terminalsControl circuit: cable 2 x 1…1.5 mm²flexible with cable end – M3
Control circuit: cable 2 x 1…1.5 mm²flexible without cable end – M3
Control circuit: cable 1 x 1…2.5 mm²flexible with cable end – M3
Control circuit: cable 1 x 1…2.5 mm²flexible without cable end – M3
Tightening torqueControl circuit: 0.8…1.2 N.m on cable, 4.7 mm
height71 mm
Width70 mm
Depth68 mm
Net weight0.325 kg
Environment
StandardsIEC 60947-4-1
IP degree of protectionIP20 conforming to IEC 60529
Ambient air temperature for operation-20…60 °C conforming to IEC 60947-4-1
Ambient air temperature for storage-30…80 °C
Operating altitude2000 m
Fire resistance650 °C conforming to IEC 60695-2-12
960 °C conforming to UL 94
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-7
Vibration resistance4 gn on panel mounting conforming to IEC 60068-2-6
2 gn on 35 mm DIN rail conforming to IEC 60068-2-6
Dielectric strength2 kV 50…60 Hz in between case and circuit conforming to IEC 60255-5
1 kV 50…60 Hz in between contact conforming to IEC 60255-5
2 kV 50…60 Hz in between circuit conforming to IEC 60255-5
Surge withstand6 kV conforming to IEC 61000-4-5
Electromagnetic compatibilityResistance to radiated electromagnetic fields: 10 V/m level 3 conforming to IEC 61000-4-3
Resistance to electrostatic discharge: 8 kV air, 6 kV contact conforming to IEC 61000-4-2
Resistance to fast transient: 2 kV conforming to IEC 61000-4-4
Conducted RF disturbances: 10 V conforming to EN 61000-4-6
Conducted RF disturbances: class A conforming to EN 55011
[Ith] conventional free air thermal current5 A for control circuit
Permissible current250 V, 5 A AC
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.5 cm
Package 1 Width6.3 cm
Package 1 Length5.7 cm
Package 1 Weight221.3 g
Unit Type of Package 2S03
Number of Units in Package 256
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight10.46 kg
Unit Type of Package 3P12
Number of Units in Package 3896
Package 3 Height75 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight177 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider EOCRSE2-30NS | electronic overcurrent relay – 0.5..6 A – 220 V AC”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat