-46%
, , ,

Schneider EOCRSSD-05S | Electronic overcurrent relay, EOCR Digital, 0.5 to 6A, 220VAC

Schneider Electric
Availability:

In stock


Schneider EOCRSSD-05S | Electronic overcurrent relay, EOCR Digital, 0.5 to 6A, 220VAC

6,488 EGP 12,016 EGP

In stock

Compare

Schneider EOCRSSD-05S | Electronic overcurrent relay, EOCR Digital, 0.5 to 6A, 220VAC

Schneider EOCRSSD-05S: A Comprehensive Guide

Introduction

Choosing the right motor protection relay is crucial for safeguarding your motors and ensuring optimal performance. Among the various options available, it stands out for its superior features and reliability. In this article, we will explore the various aspects of this product, helping you understand why it might be the perfect fit for your needs.

What is Schneider EOCRSSD-05S?

it is a high-performance motor protection relay designed to provide reliable protection for motors against various electrical faults. Known for its robust build and advanced features, this relay ensures your motors remain protected and operate efficiently.

Technical Specifications

it offers a range of impressive specifications, including:

  • Current range: 0.5-6A
  • Trip class: 10A, 10, 20, 30
  • Voltage: 220-480V AC
  • Frequency: 50/60Hz
  • Communication: RS485 Modbus

These specifications make it a reliable choice for protecting motors in various industrial and commercial applications.

Design and Build Quality

One of the standout features of it is its superior design and build quality. It is constructed from high-grade materials, ensuring durability and reliability. The compact design allows for easy installation in any environment, making it an ideal choice for both new installations and retrofits.

Installation Process

Installing it is a straightforward process:

  1. Unpacking: Remove the relay from the packaging and check for any damages.
  2. Placement: Mount the relay in a suitable location within the motor control panel.
  3. Wiring: Connect the relay to the motor and power supply according to the wiring diagram.
  4. Configuration: Configure the relay settings as per the motor’s requirements.

Following these steps will ensure a smooth installation process.

Applications and Use Cases

it is versatile and can be used in various environments, such as:

  • Industrial plants
  • Commercial buildings
  • Manufacturing facilities

Real-world examples include its use in industrial plants to protect motors from overloads and short circuits, and in commercial buildings to ensure HVAC systems operate efficiently.

Advantages of Using Schneider EOCRSSD-05S

There are numerous benefits to using it, including:

Precision and Accuracy: Provides accurate protection for motors, reducing the risk of damage.

Safety Features: Includes advanced protection mechanisms to safeguard motors against electrical faults.

Cost-Effectiveness: Offers great value for money with its reliable performance and long-term benefits.

Main
Range of productEOCR
Device short nameEOCR-SSD
product or component typeProtection relay
Protection typeOverload, In > OC setting
Sensitivity to phase loss
Locked rotor for starting, In > 2 times OC setting
Product specific applicationOvercurrent protection
Network typeAC
Network frequency50…60 Hz
protection ajustment range0.5…6 A
Tripping threshold0.5…6 A
Complementary
[Us] rated supply voltage220 V AC
Mounting support35 mm DIN rail
Panel
Contacts type and composition1 NC + 1 NO (OL)
Short-circuit and overload protectionBy 4 A gG fuse
[Ue] rated operational voltage600 V AC 50…60 Hz for power circuit conforming to UL
690 V AC 50…60 Hz for power circuit conforming to CSA
690 V AC 50…60 Hz for power circuit conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-4-1
ResetManual reset
Electrical 0…1 s by interruption of power supply
Time delay typeD-Time: 1…30 s
O-Time: 0.5, 1…10 s
Display type7 segments LED
power consumption per relay3 W
Connections – terminalsControl circuit: lug-clamp 2 x 1…2.5 mm²flexible without cable end – M3.5
Control circuit: cable 2 x 1…2.5 mm²flexible without cable end – M3.5
Control circuit: cable 2 x 1…2.5 mm²flexible with cable end – M3.5
Tightening torqueControl circuit: 1.7 N.m on lug-clamp, cable, 7 mm
Height70 mm
Width56 mm
Depth77.2 mm
net weight0.255 kg
Environment
StandardsIEC 60947-4-1
IP degree of protectionIP20 conforming to IEC 60529
Ambient air temperature for operation-20…60 °C conforming to IEC 60947-4-1
Ambient air temperature for storage-30…80 °C
Operating altitude2000 m
Fire resistance650 °C conforming to IEC 60695-2-12
960 °C conforming to UL 94
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-7
Vibration resistance4 gn on panel mounting conforming to IEC 60068-2-6
2 gn on 35 mm DIN rail conforming to IEC 60068-2-6
Dielectric strength2 kV 50…60 Hz in between case and circuit conforming to IEC 60255-5
1 kV 50…60 Hz in between contact conforming to IEC 60255-5
2 kV 50…60 Hz in between circuit conforming to IEC 60255-5
Surge withstand6 kV conforming to IEC 61000-4-5
Electromagnetic compatibilityResistance to radiated electromagnetic fields: 10 V/m level 3 conforming to IEC 61000-4-3
Resistance to electrostatic discharge: 8 kV air, 6 kV contact conforming to IEC 61000-4-2
Resistance to fast transient: 2 kV conforming to IEC 61000-4-4
Conducted RF disturbances: 10 V conforming to EN 61000-4-6
Conducted RF disturbances: class A conforming to EN 55011
[Ith] conventional free air thermal current5 A for control circuit
Permissible current250 V, 5 A
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.9 cm
Package 1 Width8.2 cm
Package 1 Length7.9 cm
Package 1 Weight196.0 g
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider EOCRSSD-05S | Electronic overcurrent relay, EOCR Digital, 0.5 to 6A, 220VAC”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat