-31%

Schneider EZC100F3015 | circuit breaker Easypact EZC100F – TMD – 15 A – 3 poles 3d

Schneider Electric
Availability:

In stock


Schneider EZC100F3015 | circuit breaker Easypact EZC100F – TMD – 15 A – 3 poles 3d

4,352 EGP 6,307 EGP

In stock

Compare

Schneider EZC100F3015 | circuit breaker Easypact EZC100F – TMD – 15 A – 3 poles 3d

Schneider EZC100F3015 | EasyPact EZC Molded Case Circuit Breaker

The Schneider EZC100F3015 is a molded case circuit breaker (MCCB) from the EasyPact EZC100F series, designed to provide protection against overloads and short circuits in low voltage electrical systems.

 Key Specifications

  • Product Series: EasyPact EZC100F

  • Part Number: EZC100F3015

  • Rated Current (In): 15 A

  • Frame Size: 100 A

  • Rated Operational Voltage (Ue): Up to 415 V AC

  • Breaking Capacity: Typically 25 kA at 415 V AC (check exact model variant for confirmation)

  • Number of Poles: 3P (Three-phase application)

  • Trip Unit Type: Fixed thermal-magnetic trip

  • Mounting: Fixed, suitable for panel mounting

  • Standards: Complies with IEC 60947-2

 Features & Benefits

  • Protection Functions:

    • Thermal protection against overloads

    • Magnetic protection against short circuits

  • Compact Size: Optimized dimensions for space-saving in switchboards

  • Durable Design: Built to handle demanding industrial and commercial environments

  • Safety: Designed to provide high performance and reliable circuit protection

  • Versatile Applications: Suitable for use in distribution panels, motor protection, and general electrical protection

 Typical Applications

  • Industrial power distribution

  • Commercial building electrical panels

  • Motor circuit protection

  • Backup and branch circuit protection

  • General-purpose electrical systems

SKU: EZC100F3015 Category: Brand:
Main
Range of productEasyPact
Product or component typeCircuit breaker
Device short nameEasypact EZC100F
circuit breaker nameEasypact EZC100F
Device applicationDistribution
Poles description3P
Protected poles description3t
Network typeAC
DC
Network frequency50/60 Hz
[In] rated current15 A at 40 °C
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
Breaking capacity codeF
Breaking capacity25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 125 V DC 1P conforming to IEC 60947-2
5 kA Icu at 250 V DC 2P conforming to IEC 60947-2
5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 125 V DC conforming to IEC 60947-2
2.5 kA at 250 V DC conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-2
utilisation categoryCategory A
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating15 A at 50 °C
Protection typeShort-circuit protection
Overload protection
Pollution degree3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary
control typeToggle
Mounting modeFixed
mounting supportBackplate
Upside connectionFront
downside connectionFront
Mechanical durability8500 cycles
Electrical durabilityCategory A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch25 mm
local signallingPositive contact indication
Neutral protection settingWithout protection
earth-leakage protectionWithout
height130 mm
Width75 mm
Depth60 mm
Environment
StandardsJIS C8201-2-2
EN/IEC 60947-1
GB/T 14048.2
EN/IEC 60947-2
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-35…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.5 cm
Package 1 Width8.2 cm
Package 1 Length14.0 cm
Package 1 Weight817.0 g
Unit Type of Package 2S02
Number of Units in Package 212
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight9.892 kg
Unit Type of Package 3P12
Number of Units in Package 3384
Package 3 Height75 cm
Package 3 Width120 cm
Package 3 Length80 cm
Package 3 Weight330 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider EZC100F3015 | circuit breaker Easypact EZC100F – TMD – 15 A – 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!