-31%

Schneider EZC100H3020 | circuit breaker Easypact EZC100H – TMD – 20 A – 3 poles 3d

Schneider Electric
Availability:

In stock


Schneider EZC100H3020 | circuit breaker Easypact EZC100H – TMD – 20 A – 3 poles 3d

6,540 EGP 9,478 EGP

In stock

Compare

Schneider EZC100H3020 | circuit breaker Easypact EZC100H – TMD – 20 A – 3 poles 3d

The Schneider EZC100H3020 is a molded case circuit breaker (MCCB) from the EasyPact EZC100H series, engineered for low-voltage electrical systems. Designed to provide reliable and efficient protection, it features a thermal-magnetic (TMD) trip unit that offers both overload and short-circuit protection.

 Technical Specifications

  • Model: EZC100H3020

  • Series: EasyPact EZC100H

  • Rated Current (In): 20 A

  • Number of Poles: 3P (Three poles)

  • Trip Unit Type: Thermal-Magnetic (TMD), Fixed

  • Mounting Style: Fixed

  • Terminal Type: 3D (Direct connection, 3-pole)

  • Rated Operational Voltage (Ue): Up to 415 V AC

  • Rated Insulation Voltage (Ui): Up to 690 V AC

  • Breaking Capacity (Icu): High – typically 36 kA at 415 V AC

  • Standards Compliance: IEC 60947-2

 Key Features

  • Dual Protection:

    • Thermal (against overloads)

    • Magnetic (against short circuits)

  • Compact & Robust Design:
    Ideal for installation in distribution panels or machinery

  • High Breaking Capacity:
    Offers reliable performance even in demanding environments

  • User-Friendly Terminals:
    3D direct terminal type for straightforward wiring

 Applications

  • Industrial and commercial power distribution

  • Protection for feeders, branch circuits, and machines

  • Control panels and motor protection

  • Sub-distribution boards

The Schneider EZC100H3020 MCCB is a compact, high-performance solution for protecting circuits in a variety of electrical installations, ensuring safety, reliability, and long-term service.

SKU: EZC100H3020 Category: Brand:
Main
Range of productEasyPact
Product or component typeCircuit breaker
Device short nameEasypact EZC100H
circuit breaker nameEasypact EZC100H
Device applicationDistribution
Poles description3P
Protected poles description3t
Network typeDC
AC
Network frequency50/60 Hz
[In] rated current20 A at 40 °C
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
Breaking capacity codeH
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2
10 kA Icu at 250 V DC 2P conforming to IEC 60947-2
10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 125 V DC conforming to IEC 60947-2
5 kA at 250 V DC conforming to IEC 60947-2
50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-2
utilisation categoryCategory A
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating20 A at 50 °C
Protection typeShort-circuit protection
Overload protection
Pollution degree3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary
control typeToggle
Mounting modeFixed
mounting supportBackplate
Upside connectionFront
downside connectionFront
Mechanical durability8500 cycles
Electrical durabilityCategory A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch25 mm
local signallingPositive contact indication
Neutral protection settingWithout protection
earth-leakage protectionWithout
height130 mm
Width75 mm
Depth60 mm
Environment
StandardsGB/T 14048.2
JIS C8201-2-2
EN/IEC 60947-1
EN/IEC 60947-2
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-35…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.5 cm
Package 1 Width8.0 cm
Package 1 Length14.0 cm
Package 1 Weight794.0 g
Unit Type of Package 2S02
Number of Units in Package 212
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight9.87 kg
Unit Type of Package 3P12
Number of Units in Package 3384
Package 3 Height75 cm
Package 3 Width120 cm
Package 3 Length80 cm
Package 3 Weight330 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider EZC100H3020 | circuit breaker Easypact EZC100H – TMD – 20 A – 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!