-33%
, , ,

Schneider G12E3A25 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 25A rating, TMD trip unit, adjustable thermal protection

Schneider Electric
Availability:

In stock


Schneider G12E3A25 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 25A rating, TMD trip unit, adjustable thermal protection

4,936.34 EGP 7,313.10 EGP

In stock

Schneider G12E3A25 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 25A rating, TMD trip unit, adjustable thermal protection

Technical Specifications G12E3A25 

  • Product Name: GoPact MCCB 125 – 25A

  • Product Type: Molded Case Circuit Breaker (MCCB)

  • Number of Poles: 3 poles

  • Rated Current (In): 25 Amps

  • Frame Size: 125 A

  • Rated Operational Voltage (Ue): Up to 415 VAC

  • Breaking Capacity (Icu): 15 kA at 415 VAC

  • Trip Unit Type: TMD (Thermal Magnetic Trip Unit)

  • Thermal Trip: Adjustable — provides custom overload protection

  • Magnetic Trip: Fixed — fast disconnection during short-circuits

  • Frequency: 50/60 Hz

  • Mounting Type: Fixed mounting (typically panel-mounted)

  • Standards Compliance: IEC 60947-2

  • Utilization Category: AC-22A (switching and protection of mixed resistive and inductive loads)

Key Features G12E3A25 

  • Reliable Protection for Low-Current Circuits
    Designed to provide precise protection for circuits operating at or below 25A, this MCCB prevents both overload and short-circuit faults.

  • Adjustable Thermal Trip
    Fine-tuning capability allows adaptation of the thermal response to match the specific needs of the connected load, improving coordination and reducing nuisance tripping.

  • Compact and Durable Construction
    Built for space-saving installations with robust mechanical strength and high endurance suitable for industrial and commercial use.

  • Quick Response to Faults
    The fixed magnetic trip ensures instant break in the event of high-current faults, limiting equipment damage and improving safety.

  • Simplified Installation
    Front-access terminals and standard mounting dimensions allow for fast and flexible integration into electrical panels.

  • Cost-Effective Performance
    Offers Schneider-quality protection in a competitively priced package for low-power applications.

Applications

  • Lighting and Socket Circuits in Commercial Spaces
    Ideal for powering and protecting branch circuits in offices, shops, hotels, and educational facilities.

  • Control and Automation Panels
    Suited for auxiliary protection of PLCs, signal circuits, and low-power contactor coils within automated systems.

  • Low-Current Industrial Loads
    Used to safeguard motors, pumps, or HVAC equipment with a full-load current around 25A.

  • Renewable Energy Systems
    Can be installed in AC distribution panels of solar or hybrid energy systems to protect downstream equipment.

  • Backup Systems and UPS Circuits
    Protects distribution circuits connected to uninterruptible power supply systems or emergency power sources.

  • Infrastructure and Public Sector Installations
    Perfect for managing small sub-circuits in hospitals, airports, telecom systems, and water management facilities.

brands

Main
Range of product GoPact MCCB
product or component type Circuit breaker
Product name GoPact MCCB 125
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 25 A at 40 °C
[Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level E 15 kA 380/415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability 30000 cycles
Electrical durability 8000 cycles at 415 V In
Power dissipation per pole 18.7 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals Screw terminals
Connection pitch 25 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 25 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.8…1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 320 A
Width (W) 75 mm
Height (H) 130 mm
Depth (D) 60 mm
net weight 0.7 kg
Colour Grey (RAL 7035)
Environment
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
Overvoltage category III
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…55 °C
ambient air temperature for storage -35…85 °C
Operating altitude 0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.4 cm
Package 1 Width 8.5 cm
Package 1 Length 13.9 cm
Package 1 Weight 908 g
Unit Type of Package 2 S02
Number of Units in Package 2 8
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.579 kg
Unit Type of Package 3 P06
Number of Units in Package 3 128
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 129.764 kg
Main
Range of product GoPact MCCB
product or component type Circuit breaker
Product name GoPact MCCB 125
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 25 A at 40 °C
[Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level E 15 kA 380/415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability 30000 cycles
Electrical durability 8000 cycles at 415 V In
Power dissipation per pole 18.7 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals Screw terminals
Connection pitch 25 mm
Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rating 25 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.8...1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 320 A
Width (W) 75 mm
Height (H) 130 mm
Depth (D) 60 mm
net weight 0.7 kg
Colour Grey (RAL 7035)
Environment
Standards EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
Overvoltage category III
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…55 °C
ambient air temperature for storage -35…85 °C
Operating altitude 0...2000 m without derating 2000...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.4 cm
Package 1 Width 8.5 cm
Package 1 Length 13.9 cm
Package 1 Weight 908 g
Unit Type of Package 2 S02
Number of Units in Package 2 8
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.579 kg
Unit Type of Package 3 P06
Number of Units in Package 3 128
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 129.764 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider G12E3A25 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 25A rating, TMD trip unit, adjustable thermal protection”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024