-31%

Schneider G12E3A63 GoPact | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 63A rating, TMD trip unit, fixed thermal protection

Availability:

In stock


Schneider G12E3A63 GoPact

5,046 EGP 7,313 EGP

In stock

Compare

Schneider G12E3A63 GoPact

Introduction

Understanding the Schneider G12E3A63 GoPact

The Schneider G12E3A63 GoPact is a versatile and reliable circuit breaker designed to provide robust protection for electrical systems in various applications. Known for its durability and advanced features, this circuit breaker is a vital component in ensuring the safety and efficiency of electrical installations.

Importance of Circuit Breakers in Electrical Systems

Circuit breakers are essential in electrical systems as they protect circuits from damage caused by overloads, short circuits, and other electrical faults. By automatically interrupting the flow of electricity when a fault is detected, they prevent potential hazards such as fires, equipment damage, and power outages.

What Makes Schneider G12E3A63 GoPact Stand Out?

Innovative Features

High Breaking Capacity

The G12E3A63 GoPact offers a high breaking capacity, making it suitable for use in demanding electrical environments where high fault currents may occur.

Compact Design

Its compact design allows for easy integration into existing electrical panels and systems, saving space and simplifying installation.

Easy Installation

Designed with user convenience in mind, the GoPact circuit breaker features straightforward installation procedures, reducing the time and effort required for setup.

Applications of Schneider G12E3A63 GoPact

Residential Buildings

In residential buildings, the GoPact circuit breaker provides reliable protection for household electrical systems, ensuring the safety of occupants and protecting appliances from electrical faults.

Commercial Buildings

For commercial buildings, the GoPact circuit breaker safeguards critical electrical infrastructure, minimizing the risk of downtime and protecting valuable equipment from damage.

Industrial Facilities

In industrial settings, the GoPact circuit breaker is used to protect heavy machinery and electrical installations, ensuring operational continuity and safety in harsh environments.

Advantages of Using Schneider G12E3A63 GoPact

Enhanced Safety

The primary advantage of the GoPact circuit breaker is its ability to enhance the safety of electrical systems by promptly interrupting fault currents and preventing potential hazards.

Reliability

Schneider Electric is renowned for producing high-quality electrical components, and the GoPact circuit breaker is no exception. It offers reliable performance and long-term durability, ensuring continuous protection for electrical systems.

Cost Savings

By preventing electrical faults and minimizing the risk of equipment damage, the GoPact circuit breaker helps reduce maintenance costs and downtime, leading to significant cost savings over time.

Installation and Setup Guide

Pre-installation Preparations

Before installing the GoPact circuit breaker, ensure that the installation site meets the necessary safety and electrical requirements.

Choosing the Right Location

Select an appropriate location within the electrical panel that provides adequate space for the circuit breaker and ensures easy access for maintenance and inspection.

Electrical Requirements

Verify that the electrical supply and load characteristics match the specifications of the GoPact circuit breaker. Ensure that all necessary protective devices are in place.

Installation Process

Once the pre-installation checks are complete, proceed with mounting and wiring the circuit breaker.

Mounting the Circuit Breaker

Secure the GoPact circuit breaker onto the mounting rail or panel using the provided hardware, ensuring it is firmly attached and properly aligned.

Wiring Connections

Connect the input and output wiring to the circuit breaker terminals according to the wiring diagram provided in the manual. Ensure all connections are tight and secure to prevent electrical faults.

Maintenance and Troubleshooting

Regular Maintenance Tips

To maintain the performance and reliability of the GoPact circuit breaker, follow these maintenance guidelines:

Inspection

Regularly inspect the circuit breaker for signs of wear, damage, or overheating. Check for loose connections and ensure the breaker operates smoothly.

Cleaning

Keep the circuit breaker and its surroundings clean and free from dust and debris. Use a dry cloth or compressed air to remove dirt from the breaker components.

Troubleshooting Common Issues

If the circuit breaker experiences operational issues, use the following troubleshooting steps to diagnose and resolve problems:

Tripping

If the circuit breaker trips frequently, identify and eliminate the cause of the overload or short circuit. Check connected devices and wiring for faults.

Fault Indicators

Refer to the user manual for explanations of any fault indicators displayed on the circuit breaker. Follow the recommended actions to address the issues.

Case Studies: Real-World Applications

Residential Protection

A homeowner installs the G12E3A63 GoPact circuit breaker to protect their home’s electrical system, ensuring safety and preventing potential fire hazards caused by electrical faults.

Commercial Reliability

A commercial building manager uses GoPact circuit breakers to safeguard the building’s electrical infrastructure, reducing the risk of equipment damage and costly downtime.

Industrial Safety

An industrial facility incorporates the GoPact circuit breaker into its electrical system to protect heavy machinery and ensure continuous operation in a harsh industrial environment.

Future Trends and Developments

Smart Circuit Breakers

As technology evolves, the future of circuit breakers includes smart features such as remote monitoring, fault diagnostics, and integration with building management systems.

Enhanced Connectivity

Schneider Electric is continually improving the connectivity options for its circuit breakers, enabling more seamless integration with modern electrical and automation systems.

Predictive Maintenance

Future advancements may include predictive maintenance capabilities, allowing for real-time monitoring and early detection of potential issues, reducing downtime and maintenance costs.

Conclusion

The Schneider G12E3A63 GoPact is a reliable and efficient circuit breaker designed to provide robust protection for electrical systems in various applications. Its advanced features, ease of installation, and high performance make it an excellent choice for ensuring the safety and reliability of electrical installations. By incorporating the GoPact circuit breaker into your system, you can achieve significant safety improvements, operational efficiency, and cost savings.

SKU: G12E3A63 Category: Brand:
Main
Range of productGoPact MCCB
Product or component typeCircuit breaker
Product nameGoPact MCCB 125
Device applicationDistribution
Poles description3P
Protected poles description3D
[In] rated current63 A at 40 °C
[Ue] rated operational voltage415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance levelE 15 kA 380/415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability30000 cycles
Electrical durability8000 cycles at 415 V In
Power dissipation per pole18.7 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection terminalsScrew terminals
Connection pitch25 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating63 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Fixed
[Ir] long-time protection pick-up adjustment range1 x In
Long-time protection delay adjustment type trFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range10 x In
Width (W)75 mm
Height (H)130 mm
Depth (D)60 mm
Net weight0.7 kg
ColourGrey (RAL 7035)
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
Overvoltage categoryIII
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP20 conforming to IEC 60529
ambient air temperature for operation-20…55 °C
Ambient air temperature for storage-35…85 °C
Operating altitude0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height12.4 cm
Package 1 Width8.5 cm
Package 1 Length13.9 cm
Package 1 Weight908 g
Unit Type of Package 2S02
Number of Units in Package 28
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight7.579 kg
Unit Type of Package 3P06
Number of Units in Package 3128
Package 3 Height75 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight129.764 kg

Main Document

Data Sheet : G12E3A63 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider G12E3A63 GoPact | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 63A rating, TMD trip unit, fixed thermal protection”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat