-33%
, , ,

Schneider G12F3F32 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 32A rating, TMD trip unit, fixed thermal protection

Schneider Electric
Availability:

In stock


Schneider G12F3F32 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 32A rating, TMD trip unit, fixed thermal protection

3,877.51 EGP 5,744.46 EGP

In stock

Schneider G12F3F32 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 32A rating, TMD trip unit, fixed thermal protection

Technical Specifications G12F3F32

  1. Product Type:
    Molded Case Circuit Breaker (MCCB) from the GoPact series by Schneider Electric.

  2. Model Number:
    G12F3F32

  3. Number of Poles:
    3 poles, suitable for three-phase electrical systems.

  4. Rated Current:
    32 Amperes. This is the maximum continuous current the breaker can carry under normal conditions.

  5. Rated Operational Voltage:
    Up to 415 Volts AC. This is compatible with standard industrial and commercial power systems.

  6. Breaking Capacity:
    30 kiloamperes (kA) at 415V AC. This indicates the breaker can safely interrupt high fault currents without damage.

  7. Trip Unit Type:
    TMD (Thermal Magnetic Trip Unit). Thermal for overload protection and magnetic for short-circuit protection.

  8. Thermal Protection:
    Fixed thermal setting, pre-calibrated for overload protection.

  9. Mounting Style:
    Fixed mounting within electrical panels.

  10. Insulation and Safety:
    High-quality insulating materials provide excellent dielectric strength and safety against electrical faults.

2. Key Features G12F3F32

  1. Reliable Protection:
    Provides efficient protection against both overload and short-circuit conditions, ensuring safety of equipment and personnel.

  2. High Fault Withstand Capability:
    With a breaking capacity of 30 kA, the breaker can handle severe fault conditions without failure.

  3. Complies with International Standards:
    Manufactured according to IEC 60947-2 standards, ensuring quality, safety, and performance.

  4. Simple Installation and Maintenance:
    Designed for easy integration into panels, with accessible terminals and straightforward maintenance procedures.

  5. Durable Construction:
    Built from robust materials to withstand harsh environments and mechanical wear.

  6. Long Operational Life:
    Engineered for high endurance with consistent performance over an extended period.

  7. Efficient Power Management:
    Helps in reducing energy losses and ensures stable operation of electrical systems.

  8. Wide Environmental Tolerance:
    Operates efficiently under various ambient temperatures and challenging site conditions.

  9. Versatile Design:
    Suitable for a wide range of industrial, commercial, and infrastructure applications.

3. Common Applications (Detailed)

  1. Industrial Power Distribution Systems:
    Used for protecting machinery and production lines from electrical faults.

  2. Commercial Buildings:
    Ideal for shopping malls, hospitals, hotels, and office complexes where high power demands are present.

  3. Main and Sub Distribution Boards:
    Functions as a main breaker or feeder protection device in electrical panels.

  4. Renewable Energy Systems:
    Applied in solar and wind power installations to protect inverters, transformers, and control equipment.

  5. Workshops and Small Factories:
    Protects electric motors, compressors, and other heavy-duty equipment from overload and short-circuits.

  6. Automation and Control Panels:
    Ensures safe and reliable operation of automated systems and control devices.

  7. Water Pumping Stations:
    Used in municipal and industrial water facilities for pump protection.

  8. Data Centers and Server Rooms:
    Critical for ensuring uninterrupted power supply to sensitive electronic equipment.

brands

Main
Range of product GoPact MCCB
product or component type Circuit breaker
Product name GoPact MCCB 125
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 32 A at 40 °C
[Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 30 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level F 30 kA 380/415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability 30000 cycles
Electrical durability 8000 cycles at 415 V In
Power dissipation per pole 18.7 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals Screw terminals
Connection pitch 25 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 32 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Fixed
[Ir] long-time protection pick-up adjustment range 1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 10 x In
Width (W) 75 mm
Height (H) 130 mm
Depth (D) 60 mm
net weight 0.7 kg
Colour Grey (RAL 7035)
Environment
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
Overvoltage category III
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…55 °C
ambient air temperature for storage -35…85 °C
Operating altitude 0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.4 cm
Package 1 Width 8.5 cm
Package 1 Length 13.9 cm
Package 1 Weight 908 g
Unit Type of Package 2 S02
Number of Units in Package 2 8
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.579 kg
Unit Type of Package 3 P06
Number of Units in Package 3 128
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 129.764 kg
Main
Range of product GoPact MCCB
product or component type Circuit breaker
Product name GoPact MCCB 125
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 32 A at 40 °C
[Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 30 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level F 30 kA 380/415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability 30000 cycles
Electrical durability 8000 cycles at 415 V In
Power dissipation per pole 18.7 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals Screw terminals
Connection pitch 25 mm
Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rating 32 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Fixed
[Ir] long-time protection pick-up adjustment range 1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 10 x In
Width (W) 75 mm
Height (H) 130 mm
Depth (D) 60 mm
net weight 0.7 kg
Colour Grey (RAL 7035)
Environment
Standards EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
Overvoltage category III
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…55 °C
ambient air temperature for storage -35…85 °C
Operating altitude 0...2000 m without derating 2000...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.4 cm
Package 1 Width 8.5 cm
Package 1 Length 13.9 cm
Package 1 Weight 908 g
Unit Type of Package 2 S02
Number of Units in Package 2 8
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.579 kg
Unit Type of Package 3 P06
Number of Units in Package 3 128
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 129.764 kg

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider G12F3F32 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 32A rating, TMD trip unit, fixed thermal protection”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024