1. Technical Specifications G12T3A25

  1. Product Name:
    Molded Case Circuit Breaker (MCCB)

  2. Model Number:
    G12T3A25

  3. Series:
    GoPact MCCB 125

  4. Rated Current (In):
    25 A

  5. Poles:
    3 poles

  6. Rated Voltage (Ue):
    Up to 415 VAC, 50/60 Hz

  7. Breaking Capacity (Icu):
    10 kA at 415 VAC (as per IEC 60947-2)

  8. Trip Unit Type:
    TMD (Thermal Magnetic)

  9. Thermal Protection:
    Adjustable thermal setting for overload protection

  10. Magnetic Protection:
    Fixed setting for short-circuit protection

  11. Mounting:
    Fixed type, suitable for surface or panel mounting

  12. Terminal Type:
    Standard connection terminals for ease of wiring

  13. Dimensions & Weight:
    Compact form factor – compatible with tight panel layouts (exact dimensions as per GoPact MCCB 125 family)

  14. Operating Temperature:
    -25°C to +70°C

  15. Ingress Protection:
    IP20 (with front cover), higher when mounted in an enclosure

  16. Certifications:

  • IEC 60947-2

  • CE Certified

  • RoHS & REACh Compliant

2. Key Features G12T3A25

  1. Adjustable Thermal Protection:
    Allows fine-tuning the trip setting for overload conditions, offering protection flexibility for sensitive equipment.

  2. Fixed Magnetic Trip Setting:
    Provides fast disconnection in the event of a short circuit, enhancing equipment and personnel safety.

  3. Compact and Robust Design:
    Built to deliver reliable protection in a small footprint, ideal for space-constrained electrical panels.

  4. Simple Installation:
    Quick and secure mounting with user-friendly terminals and standard accessories.

  5. Integrated Safety Measures:
    IP20-rated terminals protect against accidental contact; can be upgraded with accessories for increased protection.

  6. Reliable Operation in Harsh Conditions:
    Maintains performance across a wide range of temperatures and environmental conditions.

  7. Compatible with GoPact Accessories:
    Supports rotary handles (direct and extended), auxiliary contacts, shunt trips, etc., for enhanced control and safety.

  8. Maintenance-Free Operation:
    Long mechanical and electrical lifespan with minimal maintenance requirements.

  9. Panel Design Flexibility:
    Suitable for both main circuit protection and downstream circuit distribution applications.

  10. Cost-Effective Solution:
    Delivers essential circuit protection with Schneider Electric reliability at an economical price.

3. Common Applications G12T3A25

  1. General Load Protection:
    For lighting circuits, HVAC systems, and power outlets in commercial and residential settings.

  2. Industrial Control Panels:
    Provides feeder or branch protection in low-voltage distribution boards and motor control centers.

  3. OEM and Machinery Applications:
    Ideal for skid-mounted systems, machinery panels, and compact equipment.

  4. Renewable Energy Systems:
    Used for low-current AC protection in solar inverters and hybrid systems.

  5. Public Infrastructure:
    Suited for control cabinets in transportation, utilities, and public buildings.

  6. Data Centers and IT Rooms:
    Protects circuit branches feeding IT and telecom infrastructure.

  7. Building Distribution Boards:
    Integrated in sub-distribution panels for individual circuit control and protection.

brands

Main
Range of product GoPact MCCB
product or component type Circuit breaker
Product name GoPact MCCB 125
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 25 A at 40 °C
[Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 10 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level T 10 kA 380/415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 10 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability 30000 cycles
Electrical durability 8000 cycles at 415 V In
Power dissipation per pole 18.7 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals Screw terminals
Connection pitch 25 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 25 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.8…1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 320 A
Width (W) 75 mm
Height (H) 130 mm
Depth (D) 60 mm
net weight 0.7 kg
Colour Grey (RAL 7035)
Environment
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
Overvoltage category III
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…55 °C
ambient air temperature for storage -35…85 °C
Operating altitude 0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.4 cm
Package 1 Width 8.5 cm
Package 1 Length 13.9 cm
Package 1 Weight 908 g
Unit Type of Package 2 S02
Number of Units in Package 2 8
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.579 kg
Unit Type of Package 3 P06
Number of Units in Package 3 128
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 129.764 kg
Main
Range of product GoPact MCCB
product or component type Circuit breaker
Product name GoPact MCCB 125
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 25 A at 40 °C
[Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 10 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level T 10 kA 380/415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 10 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability 30000 cycles
Electrical durability 8000 cycles at 415 V In
Power dissipation per pole 18.7 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals Screw terminals
Connection pitch 25 mm
Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rating 25 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.8...1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 320 A
Width (W) 75 mm
Height (H) 130 mm
Depth (D) 60 mm
net weight 0.7 kg
Colour Grey (RAL 7035)
Environment
Standards EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
Overvoltage category III
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…55 °C
ambient air temperature for storage -35…85 °C
Operating altitude 0...2000 m without derating 2000...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.4 cm
Package 1 Width 8.5 cm
Package 1 Length 13.9 cm
Package 1 Weight 908 g
Unit Type of Package 2 S02
Number of Units in Package 2 8
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.579 kg
Unit Type of Package 3 P06
Number of Units in Package 3 128
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 129.764 kg

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider G12T3A25 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 25A rating, TMD trip unit, adjustable thermal protection”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024