1. Technical Specifications G25B3A160

  1. Product Name:
    Molded Case Circuit Breaker (MCCB)

  2. Model Number:
    G25B3A160

  3. Product Range:
    GoPact MCCB 250

  4. Number of Poles:
    3 poles

  5. Rated Current (In):
    160 A

  6. Rated Operating Voltage (Ue):
    Up to 415 VAC, 50/60 Hz

  7. Breaking Capacity (Icu):
    25 kA at 415 VAC (according to IEC 60947-2)

  8. Trip Unit Type:
    TMD (Thermal Magnetic)

  9. Thermal Protection:
    Adjustable thermal trip — allows setting the overload protection to match circuit requirements

  10. Magnetic Protection:
    Fixed magnetic trip for short-circuit protection

  11. Installation Type:
    Fixed mounting inside panelboards or enclosures

  12. Terminal Type:
    Front-access screw terminals for reliable cable connection

  13. Operating Temperature:
    -25°C to +70°C (ambient conditions)

  14. Degree of Protection (IP):
    IP20 (can be upgraded with accessories or enclosure)

  15. Certifications and Standards:

  • IEC 60947-2

  • CE Marked

  • RoHS Compliant

  • REACh Compliant

2. Key Features G25B3A160

  1. High Breaking Capacity:
    25kA breaking capacity at 415V AC, providing excellent protection in medium fault-level environments.

  2. Adjustable Overload Protection:
    Thermal protection can be tuned to better match the actual system load, increasing selectivity and safety.

  3. Robust Short-Circuit Protection:
    Fixed magnetic protection ensures fast trip response during high fault conditions.

  4. Reliable Performance:
    Engineered for consistent operation in demanding electrical distribution systems.

  5. Durable and Long-Lasting:
    Built with high mechanical and electrical endurance to reduce downtime and extend product lifespan.

  6. User-Friendly Installation:
    Compact design with standardized mounting and connection interfaces makes installation fast and straightforward.

  7. Wide Compatibility with Accessories:
    Works seamlessly with Schneider GoPact accessories such as rotary handles, auxiliary contacts, trip alarms, and more.

  8. Panel Space Efficiency:
    Optimized for distribution panels with limited space — compact footprint, high capacity.

  9. Compliant with Global Standards:
    Meets international standards, ensuring global acceptance in various markets and applications.

  10. Enhanced System Protection:
    Reduces the risk of electrical fires, equipment damage, and unplanned outages.

3. Typical Applications G25B3A160

  1. Main LV Distribution Boards:
    Provides high-reliability protection for critical power supply branches.

  2. Industrial Control Panels:
    Protects machinery, automation circuits, and industrial loads.

  3. Infrastructure Projects:
    Used in electrical panels for buildings, metro stations, airports, and other infrastructure sites.

  4. Data Centers & IT Facilities:
    Offers selective and stable protection for sensitive power distribution.

  5. Commercial Buildings:
    Ideal for HVAC, elevator systems, lighting panels, and other high-demand circuits.

  6. Renewable Energy Systems:
    Suitable for AC-side protection in solar or hybrid installations.

  7. OEM Electrical Assemblies:
    Commonly integrated in prefabricated panels, power skids, and custom switchgear.

  8. Public Utilities and Facilities:
    Ensures safe power management in water treatment, pumping stations, and utility enclosures.

brands

Main
Range of product GoPact MCCB
product or component type Circuit breaker
Product name GoPact MCCB 250
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 160 A at 40 °C
[Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 25 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level B 25 kA 380/415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 25 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability 25000 cycles
Electrical durability 8000 cycles at 415 V In
Power dissipation per pole 25 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals Screw terminals
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 12 x In
Width (W) 105 mm
Height (H) 165 mm
Depth (D) 90 mm
net weight 1.9 kg
Colour Grey (RAL 7035)
Environment
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
Overvoltage category III
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…55 °C
ambient air temperature for storage -35…85 °C
Operating altitude 0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 18.3 cm
Package 1 Width 14.1 cm
Package 1 Length 20.4 cm
Package 1 Weight 3100 g
Unit Type of Package 2 S03
Number of Units in Package 2 2
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 6.641 kg
Unit Type of Package 3 P06
Number of Units in Package 3 24
Package 3 Height 105 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 88.192 kg
Main
Range of product GoPact MCCB
product or component type Circuit breaker
Product name GoPact MCCB 250
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 160 A at 40 °C
[Ue] rated operational voltage 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 25 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level B 25 kA 380/415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 440 V AC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 25 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical durability 25000 cycles
Electrical durability 8000 cycles at 415 V In
Power dissipation per pole 25 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals Screw terminals
Connection pitch 35 mm
Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rating 160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 12 x In
Width (W) 105 mm
Height (H) 165 mm
Depth (D) 90 mm
net weight 1.9 kg
Colour Grey (RAL 7035)
Environment
Standards EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
Overvoltage category III
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…55 °C
ambient air temperature for storage -35…85 °C
Operating altitude 0...2000 m without derating 2000...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 18.3 cm
Package 1 Width 14.1 cm
Package 1 Length 20.4 cm
Package 1 Weight 3100 g
Unit Type of Package 2 S03
Number of Units in Package 2 2
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 6.641 kg
Unit Type of Package 3 P06
Number of Units in Package 3 24
Package 3 Height 105 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 88.192 kg

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider G25B3A160 | Circuit breaker, GoPact MCCB 250, 3 poles, 25kA at 415VAC, 160A rating, TMD trip unit, adjustable thermal protection”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024