The Schneider GV2ME02 is a compact, reliable motor circuit breaker from the TeSys GV2 range, offering precise protection for motors in the 0.16 to 0.25 Ampere range. It uses thermal-magnetic technology to ensure both overload and short-circuit protection in one device.

 Key Features:

  • Product Name: GV2ME02

  • Brand: Schneider Electric

  • Range: TeSys GV2

  • Product Type: Motor Circuit Breaker

  • Technology: Thermal magnetic protection

  • Number of Poles: 3P (Three poles)

  • Current Range: 0.16 to 0.25 A

  • Terminal Type: Screw clamp terminals

  • Manual Operation: Start/Stop push buttons on front panel

 Main Applications:

  • Direct-on-line motor starting and protection

  • Overload and short-circuit protection for small motors

  • Ideal for use in industrial control panels, pumps, fans, and machine tools

 Advantages:

  • Thermal Protection: Detects and trips in case of motor overload (slow rise in current)

  • Magnetic Protection: Reacts quickly to short circuits (instantaneous trip)

  • Compact Design: Fits easily in panels, saves space

  • Easy to Use: Simple adjustment dial for current setting

  • Reliable: Proven Schneider quality and performance

 Technical Specifications:

  • Current Setting Range: 0.16 – 0.25 A

  • Rated Operational Voltage: Up to 690V AC

  • Breaking Capacity: High short-circuit interrupting capacity

  • Mounting: DIN rail or screw mounting

  • Control: Manual start/stop buttons

  • Standards Compliance: IEC 60947-2, IEC 60947-4-1

 Typical Use Cases:

  • Protection for fractional horsepower motors

  • Small pumps and ventilators

  • Laboratory equipment and compact machinery

  • Motor control centers (MCCs)

 Benefits for Installers and Panel Builders:

  • Tool-less wiring possible with screw clamp terminals

  • Fast installation and commissioning

  • Compatible with Schneider accessories (enclosures, auxiliary contacts, busbars)

  • Improves uptime by reducing nuisance trips and allowing easy manual reset

SKU: GV2ME02 Category: Brand:
Main
Range TeSys Deca
Product name TeSys GV2
TeSys Deca
Product or component type Motor circuit breaker
Device short name GV2ME
Device application Motor protection
Trip unit technology Thermal-magnetic
Complementary
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-4-1
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
Motor power kW 0.06 kW at 400/415 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
control type Push-button
[In] rated current 0.25 A
Thermal protection adjustment range 0.16…0.25 A conforming to IEC 60947-4-1
Magnetic tripping current 2.4 A
[Ith] conventional free air thermal current 0.25 A conforming to IEC 60947-4-1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1 § 7-1-6
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated duty Continuous conforming to IEC 60947-4-1
Tightening torque 1.7 N.m – on screw clamp terminal
Width 45 mm
height 89 mm
Depth 78.5 mm
Net weight 0.26 kg
Colour Dark grey
Environment
Standards EN/IEC 60947-2
EN/IEC 60947-4-1
product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
RINA
DNV-GL
UKCA
IK degree of protection IK04
IP degree of protection IP20 conforming to IEC 60529
Climatic withstand Conforming to IACS E10
Ambient air temperature for storage -40…80 °C
Fire resistance 960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation -20…60 °C
Mechanical robustness Shocks: 30 Gn for 11 ms
Vibrations: 5 Gn, 5…150 Hz
Operating altitude 2000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.800 cm
Package 1 Width 9.300 cm
Package 1 Length 8.500 cm
Package 1 Weight 231.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 5.872 kg
Contractual warranty
Warranty 18 months
Main
Range TeSys Deca
Product name TeSys GV2 TeSys Deca
Product or component type Motor circuit breaker
Device short name GV2ME
Device application Motor protection
Trip unit technology Thermal-magnetic
Complementary
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-4-1
Fixing mode 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)
Motor power kW 0.06 kW at 400/415 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
control type Push-button
[In] rated current 0.25 A
Thermal protection adjustment range 0.16…0.25 A conforming to IEC 60947-4-1
Magnetic tripping current 2.4 A
[Ith] conventional free air thermal current 0.25 A conforming to IEC 60947-4-1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1 § 7-1-6
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
Rated duty Continuous conforming to IEC 60947-4-1
Tightening torque 1.7 N.m - on screw clamp terminal
Width 45 mm
height 89 mm
Depth 78.5 mm
Net weight 0.26 kg
Colour Dark grey
Environment
Standards EN/IEC 60947-2 EN/IEC 60947-4-1
product certifications CCC UL CSA EAC ATEX LROS (Lloyds register of shipping) BV RINA DNV-GL UKCA
IK degree of protection IK04
IP degree of protection IP20 conforming to IEC 60529
Climatic withstand Conforming to IACS E10
Ambient air temperature for storage -40…80 °C
Fire resistance 960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation -20…60 °C
Mechanical robustness Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz
Operating altitude 2000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.800 cm
Package 1 Width 9.300 cm
Package 1 Length 8.500 cm
Package 1 Weight 231.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 5.872 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider GV2ME02 | Motor circuit breaker, TeSys GV2, 3P, 0.16-0.25 A, thermal magnetic, screw clamp terminals”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024