Let's Chat
-46%

Schneider GV2ME04 | Motor circuit breaker, TeSys GV2, 3P, 0.4-0.63 A, thermal magnetic, screw clamp terminals

Availability:

In stock


2,706 EGP 5,012 EGP

In stock

Compare

Schneider GV2ME04 | Motor circuit breaker, TeSys GV2, 3P, 0.4-0.63 A, thermal magnetic, screw clamp terminals

Schneider GV2ME04 description

In the realm of electrical protection and control, the Schneider GV2ME04 stands out as a crucial component. This article delves into the specifics of the Schneider GV2ME04, providing a detailed description of its features, benefits, and applications. With a focus on understanding this product’s role in enhancing electrical systems, this guide is designed to offer valuable insights into one of Schneider Electric’s key offerings.


Introduction to Schneider GV2ME04

The Schneider GV2ME04 is a part of Schneider Electric’s range of motor protection circuit breakers. These devices are designed to protect electrical motors and associated circuits from overloads and short circuits. The GV2ME04 combines advanced protection features with ease of use, making it an essential component for ensuring the longevity and reliability of motor-driven systems.

Technical Specifications

Key Features

The GV2ME04 is known for its robust protection capabilities. It features a thermal-magnetic trip unit, which offers both overload and short-circuit protection. This dual protection ensures that the motor and circuit are safeguarded against potential damage caused by electrical faults.

Electrical Characteristics

  • Rated Operational Current: Up to 4A
  • Rated Insulation Voltage: 690V
  • Rated Breaking Capacity: 10kA

Mechanical Properties

The GV2ME04 is constructed with high-quality materials that ensure its durability and resistance to harsh environmental conditions. Its compact design allows for easy installation in various panel configurations.

Design and Build Quality

Material Composition

The body of the GV2ME04 is made from a high-strength thermoplastic material, providing excellent insulation and resistance to mechanical stress. This design choice contributes to its longevity and reliability.

Durability and Reliability

The GV2ME04 is built to withstand rigorous operating conditions, making it suitable for both industrial and commercial environments. Its design incorporates features that minimize wear and tear, ensuring long-term performance.

Functionality and Operation

How the GV2ME04 Works

The GV2ME04 operates by detecting excessive current flow through the motor circuit. When an overload is detected, the device trips and interrupts the circuit, preventing potential damage. The thermal-magnetic mechanism ensures that both gradual and sudden fault conditions are addressed effectively.

Typical Applications

This device is commonly used in applications where motor protection is crucial, such as in manufacturing machinery, HVAC systems, and various industrial processes. Its versatility makes it suitable for a wide range of motor types and sizes.

Benefits of Using Schneider GV2ME04

Enhanced Safety Features

One of the primary benefits of the GV2ME04 is its ability to enhance safety by providing reliable protection against electrical faults. This reduces the risk of damage to equipment and minimizes potential hazards.

Efficiency and Performance

The GV2ME04 offers excellent performance in terms of both protection and operational efficiency. Its accurate trip settings and robust construction ensure that motors run smoothly and are protected from potential faults.

Compliance with Standards

The GV2ME04 meets various international standards for electrical safety and performance, ensuring that it adheres to industry best practices and regulations.

Installation and Maintenance

Installation Guidelines

Installing the GV2ME04 involves mounting the device in an appropriate enclosure and connecting it to the motor circuit. Detailed installation instructions are provided by Schneider Electric, ensuring a straightforward setup process.

Maintenance Tips

Routine maintenance involves checking the device for signs of wear or damage and verifying its operational settings. Regular inspections help ensure continued reliable performance.

Troubleshooting Common Issues

Common issues with the GV2ME04 include tripping due to incorrect settings or external factors affecting the motor. Troubleshooting involves checking the settings and ensuring that the motor and circuit are functioning correctly.

Comparative Analysis

GV2ME04 vs. Other Schneider Models

Compared to other Schneider models, the GV2ME04 offers a balanced combination of protection features and ease of use. It is well-suited for applications where a reliable and straightforward motor protection solution is needed.

GV2ME04 vs. Competitor Products

When compared to competitor products, the GV2ME04 stands out for its high breaking capacity and robust design. Its performance in terms of protection and reliability makes it a preferred choice for many applications.

Real-World Applications

Industrial Use Cases

In industrial settings, the GV2ME04 is used to protect motors in various machinery, including pumps, conveyors, and compressors. Its ability to handle high current levels makes it suitable for demanding applications.

Commercial and Residential Applications

The GV2ME04 is also used in commercial and residential settings, such as HVAC systems and small-scale industrial equipment. Its compact design and reliable protection make it a versatile choice for diverse applications.

SKU: GV2ME04 Category:
brands

Schneider Electric

Main
Range TeSys Deca
Product name TeSys GV2
TeSys Deca
Product or component type Motor circuit breaker
Device short name GV2ME
Device application Motor protection
Trip unit technology Thermal-magnetic
Complementary
poles description 3P
network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-4-1
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
Motor power kW 0.12 kW at 400/415 V AC 50/60 Hz
0.18 kW at 400/415 V AC 50/60 Hz
0.37 kW at 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control type Push-button
[In] rated current 0.63 A
Thermal protection adjustment range 0.4…63 A conforming to IEC 60947-4-1
Magnetic tripping current 8 A
[Ith] conventional free air thermal current 0.63 A conforming to IEC 60947-4-1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1 § 7-1-6
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated duty Continuous conforming to IEC 60947-4-1
Tightening torque 1.7 N.m – on screw clamp terminal
Width 45 mm
Height 89 mm
Depth 78.5 mm
Net weight 0.26 kg
Colour Dark grey
Environment
Standards EN/IEC 60947-2
EN/IEC 60947-4-1
Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
RINA
DNV-GL
UKCA
UKCA
IK degree of protection IK04
IP degree of protection IP20 conforming to IEC 60529
Climatic withstand conforming to IACS E10
Ambient air temperature for storage -40…80 °C
Fire resistance 960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation -20…60 °C
Mechanical robustness Shocks: 30 Gn for 11 ms
Vibrations: 5 Gn, 5…150 Hz
Operating altitude 2000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.500 cm
Package 1 Width 8.500 cm
Package 1 Length 9.500 cm
Package 1 Weight 216.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 5.568 kg
Unit Type of Package 3 P06
Number of Units in Package 3 384
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 98.088 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider GV2ME04 | Motor circuit breaker, TeSys GV2, 3P, 0.4-0.63 A, thermal magnetic, screw clamp terminals”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024