-46%
,

Schneider GV2ME08| Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, thermal magnetic, screw clamp terminals

Availability:

Out of stock


Schneider GV2ME08| Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, thermal magnetic, screw clamp terminals

2,826 EGP 5,233 EGP

Out of stock

Compare

Schneider GV2ME08: A Comprehensive Guide

Introduction

it is a versatile and efficient motor circuit breaker, essential for protecting motors in various applications. This guide will provide an in-depth look at its features, specifications, installation process, and much more, helping you understand why it’s a valuable component in any electrical system.

What is the Schneider GV2ME08?

The Schneider GV2ME08 is a motor circuit breaker designed to protect motors from overloads, short circuits, and phase failures. It is part of the GV2 series, known for its reliability and efficiency.

General Description

it offers robust protection for motors, ensuring they operate safely and efficiently. It is built to handle demanding environments and provides consistent performance over time.

Key Specifications

  • Voltage Rating: Up to 690V AC
  • Current Rating: 2.5-4A
  • Breaking Capacity: 100 kA at 400V AC
  • Trip Class: 10A

Intended Applications

it is suitable for various applications, including industrial machinery, HVAC systems, and commercial equipment.

Features of Schneider GV2ME08

it is packed with features that enhance its performance and reliability.

High Performance

Designed to handle a range of motor protection needs, it ensures reliable operation and protection against electrical faults.

Compact Design

Its compact size allows for easy integration into control panels and tight spaces without compromising on performance.

Safety Features

it includes features like thermal-magnetic protection and manual reset options, enhancing safety and preventing damage to motors.

Technical Specifications

Understanding the technical specifications of the Schneider GV2ME08 is crucial for proper application and installation.

Voltage Ratings

The GV2ME08 operates efficiently at voltages up to 690V AC, making it versatile for various electrical systems.

Current Capacity

With a current rating of 2.5-4A, it can protect motors within this range, ensuring they operate within safe limits.

Operating Temperature Range

The operating temperature range of -20°C to 60°C allows the GV2ME08 to function effectively in diverse environmental conditions.

Installation and Setup

Proper installation is essential for the optimal performance of the Schneider GV2ME08.

Pre-installation Requirements

Before installation, ensure all necessary tools and safety equipment are available, and that the electrical system is properly prepared.

Step-by-step Installation Guide

  1. Turn off Power: Ensure the power supply is completely shut off to prevent any electrical hazards.
  2. Mount the Breaker: Securely mount the GV2ME08 in the designated location using appropriate hardware.
  3. Connect Wires: Carefully connect the wires to the breaker terminals, following the wiring diagram.
  4. Check Connections: Double-check all connections to ensure they are secure and correctly placed.
  5. Restore Power: Turn the power back on and test the breaker to ensure it is functioning correctly.

Safety Precautions During Installation

Always follow safety guidelines, wear appropriate protective gear, and ensure the work area is free of hazards to prevent accidents during installation.

Comparing Schneider GV2ME08 with Other Models

Understanding the differences between the Schneider GV2ME08 and other models can help in selecting the right motor circuit breaker for specific needs.

Schneider GV2ME08 vs. GV2ME07

  • Current Capacity: The GV2ME08 has a higher current capacity range (2.5-4A) compared to the GV2ME07 (1.6-2.5A).
  • Applications: The GV2ME08 is more suited for slightly higher power motors, whereas the GV2ME07 is ideal for lower power motors.

Schneider GV2ME08 vs. GV2ME10

  • Current Capacity: The GV2ME10 offers a higher current range (4-6.3A), making it suitable for more powerful motors.
  • Performance: Both models offer similar performance, but the choice depends on the specific motor requirements.

Benefits of Choosing Schneider GV2ME08

The Schneider GV2ME08 stands out for its reliable performance, robust design, and effective protection features, making it a preferred choice for many applications.

Main
RangeTeSys Deca
Product nameTeSys GV2
TeSys Deca
product or component typeMotor circuit breaker
Device short nameGV2ME
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Complementary
poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
Motor power kW1.1 kW at 400/415 V AC 50/60 Hz
1.5 kW at 400/415 V AC 50/60 Hz
1.5 kW at 500 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
3 kW at 690 V AC 50/60 Hz
2.2 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typePush-button
[In] rated current4 A
Thermal protection adjustment range2.5…4 A conforming to IEC 60947-4-1
Magnetic tripping current51 A
[Ith] conventional free air thermal current4 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1 § 7-1-6
Power dissipation per pole2.5 W
Mechanical durability100000 cycles
Electrical durability100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque1.7 N.m – on screw clamp terminal
Width45 mm
Height89 mm
Depth78.5 mm
net weight0.26 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
RINA
DNV-GL
UKCA
IK degree of protectionIK04
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 30 Gn for 11 ms
Vibrations: 5 Gn, 5…150 Hz
Operating altitude2000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.800 cm
Package 1 Width8.500 cm
Package 1 Length9.300 cm
Package 1 Weight253.000 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.414 kg
Unit Type of Package 3P06
Number of Units in Package 3384
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight109.232 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider GV2ME08| Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, thermal magnetic, screw clamp terminals”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat