Product Overview:
The Schneider Electric GV2P16 is a compact and reliable motor circuit breaker from the TeSys GV2 series. Engineered for direct-on-line motor starting and protection, this device features thermal-magnetic protection against overloads and short circuits, with an adjustable current range from 9 to 14 A. Its 3-pole design and screw clamp terminals make it ideal for integration into control panels and motor control centers.

Key Features:

  • Adjustable Current Range: 9 – 14 A

  • Poles: 3P (Three-phase)

  • Protection Type: Thermal-magnetic (for both overload and short-circuit)

  • Trip Class: Class 10 (fast response for motor protection)

  • Terminals: Screw clamp – quick and secure wiring

  • Reset Option: Manual with visual trip indication

  • Mounting Type: DIN rail or backplate mounting

  • High Breaking Capacity: Up to 100 kA at 400 V

Applications:

  • Electric motor protection and control

  • Industrial automation systems

  • HVAC, compressors, conveyors, and pumps

  • Machinery panels and distribution boards

Advantages:

  • Compact and modular design for panel space optimization

  • Adjustable current range to cover different motor sizes

  • High-performance protection for industrial reliability

  • Fully compatible with Schneider LC1D contactors and accessories

  • TeSys GV motor circuit breaker, 3 poles (3P), 14A/690V, for 3-phase motor applications 5.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 9-14A, magnetic tripping at 13xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by rotary knob guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
SKU: GV2P16 Category: Brand:
Main
RangeTeSys Deca
Product nameTeSys GV2
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV2P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 2 x M4 screws)
Motor power kW5.5 kW at 400/415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 690 V AC 50/60 Hz
11 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
control typeRotary handle
[In] rated current14 A
Thermal protection adjustment range9…14 A conforming to IEC 60947-4-1
Magnetic tripping current170 A
[Ith] conventional free air thermal current14 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1 § 7-1-6
Power dissipation per pole2.5 W
Mechanical durability100000 cycles
Electrical durability100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque1.7 N.m – on screw clamp terminal
Width45 mm
height89 mm
Depth97 mm
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
RINA
DNV-GL
UKCA
IK degree of protectionIK04
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 30 Gn for 11 ms
Vibrations: 5 Gn, 5…150 Hz
Operating altitude2000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.800 cm
Package 1 Width9.500 cm
Package 1 Length10.000 cm
Package 1 Weight336.000 g
Unit Type of Package 2S02
Number of Units in Package 220
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.858 kg
Unit Type of Package 3P06
Number of Units in Package 3320
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight109.260 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews