Specifications:

  • Current Rating: 23 to 32 A, suitable for a variety of motor sizes.
  • Protection Type: Thermal-magnetic, protecting against overloads and short circuits.
  • Easy Installation: Equipped with EverLink BTR connectors for flexible and quick wiring with multi-standard screw connections.
  • Rotary Knob: For easy adjustment of the settings.
  • Compact Design: Ensures compatibility with industrial applications where space is limited.
  • Rated Voltage: Up to 690 VAC, suitable for high voltage applications.
  • Environmental Protection: IP20 rating ensures adequate protection against dust and foreign objects.

Features:

  1. Integrated Protection: Offers both thermal protection for overload conditions and magnetic protection for short circuits, ensuring the motor’s safety.
  2. User-Friendly Operation: The device features a rotary knob for convenient control and setting adjustments.
  3. Flexible Connections: The EverLink BTR connectors ensure easier installation and secure connections, even in tight spaces.
  4. Durability: Designed to operate efficiently even in harsh industrial environments, it offers long-lasting performance.
  5. Environmental Sustainability: The device is part of Schneider Electric’s efforts to provide sustainable, energy-efficient products that help businesses meet environmental goals.

Applications:

  • The GV3P32 is commonly used in industrial machinery, pumps, compressors, and any other motor-driven equipment that requires reliable protection against electrical faults.
  • It’s ideal for applications where motor protection, safety, and reliable performance are essential in ensuring smooth operations.
Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Complementary
poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current32 A
Thermal protection adjustment range23…32 A conforming to IEC 60947-4-1
Magnetic tripping current448 A
[Ith] conventional free air thermal current32 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandconforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight1.001 kg
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight133.120 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider GV3P32 | Motor circuit breaker, TeSys GV3, 3P, 23-32 A, thermal magnetic, EverLink terminals”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat