-46%
, , ,

Schneider GV3P65 | Motor circuit breaker, TeSys GV3, 3P, 48-65 A, thermal magnetic, EverLink terminals

Schneider Electric
Availability:

In stock


Schneider GV3P65 | Motor circuit breaker, TeSys GV3, 3P, 48-65 A, thermal magnetic, EverLink terminals

11,167 EGP 20,680 EGP

In stock

Compare

Schneider GV3P65 | Motor circuit breaker, TeSys GV3, 3P, 48-65 A, thermal magnetic, EverLink terminals

Key Specifications:

  • Current Range: 48A to 65A, suitable for medium to large motors.
  • Voltage Rating: Up to 690V AC.
  • Protection Type: Thermal-magnetic protection, which combines both thermal overload and magnetic short circuit protection.
  • Adjustable Thermal Setting: Allows fine-tuning of the overload protection to suit different motor types and sizes.
  • Rated Power: Handles up to 75 kW at 400V for three-phase motors.
  • Enclosure Protection: IP20, ensuring basic protection against contact with internal components and dust ingress.

Key Features:

  1. Thermal-Magnetic Protection: Provides comprehensive protection for motors against both overloads (due to excessive current) and short circuits (due to faults in the system).
  2. Manual Isolation and Control: The GV3P65 allows for manual switching and disconnection of the motor from the electrical supply, enhancing safety during maintenance.
  3. Compact and Robust Design: Its space-efficient, durable design is suited for various industrial environments, even in harsh conditions.
  4. User-Friendly Operation: Easy-to-use rotary knob for simple setting adjustments and reliable operation.
  5. High Durability: Rated for long-term performance with a high mechanical endurance, ideal for continuous industrial applications.

Applications:

  • Industrial Machinery: Commonly used in controlling and protecting motors for machines that require regular and reliable operation.
  • Pumps: Ideal for pump systems that require protection against electrical faults and overload conditions.
  • Conveyors and Automation Systems: Provides motor protection in automated material handling systems.
  • HVAC Systems: Suitable for motor-driven HVAC equipment where motor protection and control are critical.
Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Complementary
poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW30 kW at 400/415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current65 A
Thermal protection adjustment range48…65 A conforming to IEC 60947-4-1
Magnetic tripping current910 A
[Ith] conventional free air thermal current65 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandconforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.600 cm
Package 1 Weight1.016 kg
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight134.920 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider GV3P65 | Motor circuit breaker, TeSys GV3, 3P, 48-65 A, thermal magnetic, EverLink terminals”