-46%
,

Schneider GV3P73 | Motor circuit breaker, TeSys GV3, 3P, 62-73 A, thermal magnetic, EverLink terminals

Schneider Electric
Availability:

In stock


Schneider GV3P73 | Motor circuit breaker, TeSys GV3, 3P, 62-73 A, thermal magnetic, EverLink terminals

12,589.00 EGP 23,313.00 EGP

In stock

Schneider GV3P73 | Motor circuit breaker, TeSys GV3, 3P, 62-73 A, thermal magnetic, EverLink terminals

Schneider GV3P73 | Motor Circuit Breaker – TeSys GV3, 3P, 62–73 A, Thermal Magnetic, EverLink Terminals

Product Overview:
The Schneider Electric GV3P73 is a motor circuit breaker from the TeSys GV3 series, designed to protect motors and equipment against overloads, phase failure, and short circuits. It features an adjustable current range of 62 to 73 A, making it ideal for medium-power motor applications. The advanced EverLink™ terminals ensure secure, long-lasting connections even under thermal cycling and vibration.

Key Features:

  • Current Range: 62 – 73 A (adjustable)

  • Poles: 3P (Three-phase)

  • Protection Type: Thermal-magnetic (overload + short-circuit protection)

  • Terminal Technology: EverLink™ – maintains tightening torque over time

  • Trip Class: Class 10 – fast motor protection

  • Mounting: DIN rail or backplate

  • Reset Options: Manual with visual trip indicator

  • High Breaking Capacity: Up to 65 kA at 400 V

Applications:

  • Medium-power motor protection in industrial environments

  • Machine tools, pumps, compressors, HVAC systems

  • Control panels in manufacturing and automation setups

  • Any 3-phase motor control with high mechanical vibration or heat

Benefits:

  • EverLink™ Terminals: Reduces connection failure due to loosening

  • Comprehensive Protection: Covers overload, short circuit, and phase loss

  • High Interrupting Capacity: Ensures safe fault isolation

  • Modular Design: Compatible with TeSys accessories (auxiliary contacts, shunt trips, etc.)

  • TeSys GV motor circuit breaker, 3 poles (3P), 73A/690V, for 3-phase motor applications 37kW@400V. It provides a thermal-magnetic protection with a thermal setting range 62-73A, magnetic tripping at 15xIn, high breaking capacity Icu 50kA@400V. Connection by Everlink BTR screw terminals. Start-stop control by rotary knob guaranteed for 20 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
SKU: GV3P73 Categories: , Brand:
Main
Range TeSys Deca
Product name TeSys GV3
TeSys Deca
Product or component type Motor circuit breaker
Device short name GV3P
Device application Motor protection
Trip unit technology Thermal-magnetic
Complementary
Poles description 3P
Network type AC
Utilisation category AC-3 conforming to IEC 60947-4-1
Network frequency 50/60 Hz
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW 37 kW at 400/415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity 65 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz
60 % at 400/415 V AC 50/60 Hz
60 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
control type Rotary handle
[In] rated current 73 A
Thermal protection adjustment range 62…73 A conforming to IEC 60947-4-1
Magnetic tripping current 1120 A
[Ith] conventional free air thermal current 73 A conforming to IEC 60947-4-1
[Ue] rated operational voltage 690 V AC 50/60 Hz
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 20000 cycles for AC-3 at 415 V In
Rated duty Continuous conforming to IEC 60947-4-1
Tightening torque 5 N.m – on screw clamp terminal
Width 55 mm
height 132 mm
Depth 136 mm
Net weight 0.96 kg
Colour Dark grey
Environment
Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protection IK09 enclosure
IP degree of protection IP20 conforming to IEC 60529
Climatic withstand Conforming to IACS E10
Ambient air temperature for storage -40…80 °C
Fire resistance 960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation -20…60 °C
Mechanical robustness Shocks: 5 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude 3000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.800 cm
Package 1 Width 14.800 cm
Package 1 Length 16.000 cm
Package 1 Weight 1.008 kg
Unit Type of Package 2 P06
Number of Units in Package 2 120
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 130.480 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0