-46%
,

Schneider GV4LE07N | TeSys Deca, Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, magnetic, EverLink terminals

Availability:

In stock


18,862 EGP 34,930 EGP

In stock

Compare

Schneider GV4LE07N | TeSys Deca, Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, magnetic, EverLink terminals

TeSys GV motor circuit breaker, 3 poles (3P), 7A/690V, for protection of 3-phase motors 1.5-3kW@400V. It provides magnetic protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV4LE07N?

The Schneider GV4LE07N is a state-of-the-art circuit breaker designed to protect electrical circuits from damage caused by overloads or short circuits. It’s renowned for its robust performance and reliability in various electrical systems.

Technical Specifications

Understanding the technical specs of the GV4LE07N is crucial for selecting the right component for your needs.

  • Voltage Ratings: This model operates efficiently at standard voltage levels, ensuring compatibility with most electrical systems.
  • Current Ratings: The GV4LE07N can handle a substantial current load, making it suitable for heavy-duty applications.
  • Breaking Capacity: It boasts a high breaking capacity, ensuring it can safely interrupt fault currents without damaging the system.

Design and Build

The GV4LE07N is built with precision and durability in mind.

  • Physical Dimensions: Compact and space-efficient, it fits well in various setups.
  • Materials Used: Made from high-quality materials, it ensures longevity and reliable performance.
  • Durability Factors: Designed to withstand harsh conditions, it’s a reliable choice for long-term use.

Installation Process

Installing the Schneider GV4LE07N is straightforward if you follow these steps:

  1. Prepare the tools: Ensure you have all the necessary tools and safety equipment.
  2. Turn off the power: Always shut down the power supply before starting the installation.
  3. Mount the breaker: Secure the breaker in the designated panel space.
  4. Connect the wires: Follow the wiring diagram provided in the manual.
  5. Test the installation: Once installed, turn the power back on and test the breaker to ensure it’s working correctly.

Applications of Schneider GV4LE07N

This circuit breaker is versatile and can be used in various settings:

  • Industrial Uses: Ideal for factories and manufacturing plants where heavy machinery is in operation.
  • Commercial Applications: Suitable for office buildings, shopping malls, and other commercial spaces.
  • Residential Scenarios: Can be used in homes for additional safety and protection of electrical systems.

Advantages of Using Schneider GV4LE07N

There are several reasons why the GV4LE07N stands out:

  • Safety Features: It includes advanced safety mechanisms to prevent electrical hazards.
  • Reliability: Known for consistent performance, reducing the risk of electrical failures.
  • Cost-Effectiveness: Offers a good balance between price and performance, providing excellent value for money.

Comparison with Similar Products

When compared to other circuit breakers, the GV4LE07N holds its own due to:

  • Unique Selling Points: Features like higher breaking capacity and better durability set it apart from competitors.
  • Schneider GV4LE07N vs. Competitors: While others might offer similar specs, the overall reliability and brand trust of Schneider make it a preferred choice.

User Reviews and Feedback

Customers generally have positive feedback about the GV4LE07N:

  • Common Praises: Users often highlight its reliability and ease of installation.
  • Typical Complaints: Some users might find it a bit pricier compared to other brands, but the quality justifies the cost.
  • Overall Satisfaction: High satisfaction rates due to its performance and safety features.

Maintenance Tips

To ensure your GV4LE07N lasts longer and performs optimally, follow these maintenance tips:

  • Regular Checks: Periodically inspect the breaker for any signs of wear or damage.
  • Troubleshooting Common Issues: Familiarize yourself with basic troubleshooting to handle minor issues.
  • Extending the Lifespan: Ensure proper installation and avoid overloading the breaker to maximize its lifespan.

Where to Buy Schneider GV4LE07N

When looking to purchase the GV4LE07N, consider these options:

  • Online Retailers: Websites like Amazon and eBay offer a wide range of options.
  • Authorized Distributors: Buying from authorized sellers ensures you get genuine products.
  • Tips for Avoiding Counterfeits: Always check the seller’s credentials and reviews to avoid counterfeit products.

Understanding the Model Number: GV4LE07N

The model number provides essential information about the breaker:

  • Breakdown of the Model Code: Each part of the code represents specific attributes of the breaker.
  • Significance of Each Part: Understanding this can help you select the right breaker for your needs.

Future Trends in Circuit Breakers

The future of circuit breakers like the GV4LE07N is exciting, with several trends on the horizon:

  • Technological Advancements: Expect smarter and more efficient breakers with enhanced features.
  • Sustainability Initiatives: Eco-friendly designs and materials are becoming more prevalent.
  • Market Predictions: The demand for reliable circuit breakers is expected to grow, driven by technological advancements and increased safety standards.

FAQs

  1. What makes the Schneider GV4LE07N unique?
    • Its high breaking capacity and reliable performance set it apart from similar products.
  2. Can I install the GV4LE07N myself?
    • While possible, it’s recommended to have a professional handle the installation for safety reasons.
  3. What should I do if my GV4LE07N trips frequently?
    • Frequent tripping could indicate an overload or fault in the system. It’s best to consult a professional to diagnose the issue.
  4. Where can I find the user manual for the GV4LE07N?
    • The user manual is usually included with the product, or you can download it from Schneider’s official website.
  5. Is the GV4LE07N suitable for residential use?
    • Yes, it’s versatile enough for both residential and commercial applications.

Conclusion

The Schneider GV4LE07N is a top-tier circuit breaker offering reliability, safety, and versatility. Whether for industrial, commercial, or residential use, it stands out for its advanced features and robust build. Investing in the GV4LE07N ensures peace of mind and long-term performance for your electrical systems.

Main
range of productTeSys GV4
RangeTeSys Deca
TeSys Deca
Device short nameGV4L
Product nameTeSys GV4
TeSys Deca
Product or component typeeMotor circuit breaker
Device applicationMotor protection
Trip unit technologyMagnetic
Electronic
Complementary
Poles description3P
Utilisation categoryCategory A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating positionAny position
Motor power kW1.5 kW at 400…415 V AC 50/60 Hz
2.2 kW at 400…415 V AC 50/60 Hz
2.5 kW at 400…415 V AC 50/60 Hz
3 kW at 400…415 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
2.5 kW at 500 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
3 kW at 660…690 V AC 50/60 Hz
4 kW at 660…690 V AC 50/60 Hz
5.5 kW at 660…690 V AC 50/60 Hz
7.5 kW at 660…690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
control typeToggle
[In] rated current7 A
Magnetic tripping current42…98 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2
Power dissipation per pole6.1 W
Mechanical durability40000 cycles
Electrical durability40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Maximum operating rate25 cyc/h
Rated dutyContinuous conforming to IEC 60947-4-1
Connections – terminalsEverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² – solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² – flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² – solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² – flexible
Tightening torque9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustnessVibrations: +/- 1 mm 2…13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2…100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
height155 mm
Width81 mm
Depth116 mm
Net weight1.5 kg
ColourGrey (RAL 7016)
Suitability for isolationYes conforming to IEC 60947-1
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
product certificationsIEC
CCC
EAC
EU-RO MR
Climatic withstandConforming to IACS E10
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3
IP degree of protectionIP40 conforming to IEC 60529
Ambient air temperature for storage-50…85 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Operating altitude5000 m
Ambient air temperature for operation-25…70 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.7 cm
Package 1 Width10.8 cm
Package 1 Length22.0 cm
Package 1 Weight1.697 kg
Unit Type of Package 2S03
Number of Units in Package 25
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight8.885 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : GV4LE07N

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider GV4LE07N | TeSys Deca, Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, magnetic, EverLink terminals”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat