Let's Chat
-46%
,

Schneider GVAD0110 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC (fault)

Schneider Electric
Availability:

Out of stock


983 EGP 1,821 EGP

Out of stock

Compare

Schneider GVAD0110 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC (fault)

Schneider GVAD0110 Description

Schneider GVAD0110 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC (fault)

Introduction

When it comes to industrial automation and control, the Schneider GVAD0110 stands out as a vital component. But what exactly makes it so important? This article delves into the specifics, shedding light on its features, applications, and much more. Let’s explore why the Schneider GVAD0110 is a preferred choice for many industries.

What is Schneider GVAD0110?

The Schneider GVAD0110 is a versatile auxiliary contact block designed for industrial applications. It is known for its reliability and efficiency in monitoring and controlling various electrical circuits. This auxiliary contact block is an integral part of Schneider Electric’s vast range of industrial control solutions.

Technical Specifications

Understanding the technical specifications is crucial for anyone looking to integrate the Schneider GVAD0110 into their system. Here are the key details:

  • Electrical Ratings: The GVAD0110 is rated for 6 A at 24 V DC and 10 A at 120 V AC. This ensures it can handle a variety of industrial loads without compromising performance.
  • Mechanical Properties: It features a robust design that can withstand up to 10 million mechanical operations, highlighting its durability and long service life.y.

Installation Process

Installing the Schneider GVAD0110 is straightforward, but it requires attention to detail to ensure safety and functionality. Here’s a step-by-step guide:

  1. Turn off Power: Always start by disconnecting the power supply to prevent any electrical hazards.
  2. Mount the Block: Attach the GVAD0110 to the designated position on the circuit breaker or control device.
  3. Connect the Wires: Follow the wiring diagram provided by Schneider Electric to make the necessary connections.
  4. Secure the Installation: Ensure all connections are tight and the block is securely mounted.
  5. Test the System: Once installed, turn the power back on and test the system to confirm proper operation.

Maintenance and Troubleshooting

To keep the Schneider GVAD0110 in top working condition, regular maintenance is essential. Here are some tips:

  • Regular Inspections: Check for signs of wear or damage and replace components as needed.
  • Cleaning: Keep the contact points clean to ensure efficient operation.
  • Troubleshooting: Common issues include contact wear and loose connections. These can often be resolved by inspecting and securing the connections or replacing worn contacts.

Cost and Availability

Pricing for the Schneider GVAD0110 varies depending on the supplier and quantity purchased. Generally, it is competitively priced, making it accessible for businesses of all sizes. You can purchase it from authorized Schneider Electric distributors or reputable online platforms.

Main
Range TeSys
TeSys Deca
Device short name GVAD
Product or component type Auxiliary contact block
Product compatibility GV2ME
GV2L
GV3P
GV2P
GV3L
GV2LE
GV2RT
Mounting location Left side
Auxiliary contacts operation Fault signal 1 NC
Pole contact composition 1 NO + 1 NC
Complementary
[Ui] rated insulation voltage 690 V conforming to IEC 60947-1
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
[Ue] rated operational voltage 48…690 V AC
24…240 V DC
[Ith] conventional free air thermal current 6 A
2.5 A for fault signalling
Mechanical durability 100000 cycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Protection type GB2CB… circuit breaker
GG fuse 10 A
Rated operational power in VA 300 VA at 48 V AC-15 – electrical durability: 100000 cycles
414 VA at 690 V AC-15 – electrical durability: 100000 cycles
500 VA at 110…127 V AC-15 – electrical durability: 100000 cycles
500 VA at 500 V AC-15 – electrical durability: 100000 cycles
650 VA at 440 V AC-15 – electrical durability: 100000 cycles
720 VA at 230…240 V AC-15 – electrical durability: 100000 cycles
850 VA at 380…415 V AC-15 – electrical durability: 100000 cycles
36 VA at 24 V AC-14 – electrical durability: 1000 cycles
48 VA at 48 V AC-14 – electrical durability: 1000 cycles
72 VA at 110…127 V AC-14 – electrical durability: 1000 cycles
Rated operational power in W 120 W at 240 V DC-13 – electrical durability: 100000 cycles
140 W at 110 V DC-13 – electrical durability: 100000 cycles
140 W at 24 V DC-13 – electrical durability: 100000 cycles
180 W at 60 V DC-13 – electrical durability: 100000 cycles
240 W at 48 V DC-13 – electrical durability: 100000 cycles
15 W at 48 V DC-13 – electrical durability: 1000 cycles
24 W at 24 V DC-13 – electrical durability: 1000 cycles
9 W at 60 V DC-13 – electrical durability: 1000 cycles
Tightening torque 1.4 N.m – on screw clamp terminals
height 89 mm
Width 9.3 mm
Depth 66 mm
Net weight 0.055 kg
Colour Dark grey
Environment
Environmental characteristic Normal environment
product certifications UKCA
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.700 cm
Package 1 Width 1.500 cm
Package 1 Length 6.600 cm
Package 1 Weight 47.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 10
Package 2 Height 9.500 cm
Package 2 Width 15.000 cm
Package 2 Length 10.000 cm
Package 2 Weight 500.000 g
Unit Type of Package 3 S02
Number of Units in Package 3 60
Package 3 Height 15.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 3.380 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : GVAD0110 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider GVAD0110 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC (fault)”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024