Schneider GZ1E14: Comprehensive Overview

Introduction

The Schneider GZ1E14 is a high-quality enclosure designed to provide reliable housing and protection for motor circuit breakers and related electrical components. Engineered for industrial and commercial applications, the GZ1E14 ensures safety, durability, and ease of integration into control systems.

This article explores the technical specifications, features, applications, and benefits of the Schneider GZ1E14.

Technical Specifications

  • Model Number: GZ1E14
  • Type: Enclosure for motor circuit breakers and related components
  • Material: Durable thermoplastic, offering excellent insulation and impact resistance
  • Dimensions: Compact design suitable for space-constrained setups
  • Mounting Type: Surface-mounted or panel-mounted
  • IP Rating: Protection level against dust and moisture (specific rating dependent on configuration)
  • Standards Compliance: Complies with IEC 60947 for low-voltage switchgear and controlgear

Key Features

  1. Robust Construction:
    • Built to withstand demanding industrial environments and protect internal components.
  2. Space-Efficient Design:
    • Compact enclosure that fits seamlessly into various control systems.
  3. Enhanced Safety Measures:
    • Protects electrical components from environmental factors like dust, moisture, and accidental contact.
  4. Easy Installation:
    • Pre-drilled mounting points and a user-friendly layout for quick setup.
  5. Compatibility:
    • Specifically designed to house Schneider Electric motor circuit breakers and other compatible devices.

Applications

The Schneider GZ1E14 is used in various scenarios, including:

  • Industrial Motor Protection: Enclosing motor circuit breakers to safeguard against overloads and short circuits.
  • Power Distribution Panels: Organizing and protecting low-voltage switchgear components.
  • Control Systems: Providing secure housing for critical electrical parts.
  • Outdoor Installations: Suitable for use in higher IP-rated configurations to shield from environmental factors.

Benefits

  • Safety Assurance: Reduces exposure to electrical hazards for personnel and equipment.
  • Durability: Ensures long-lasting protection for enclosed components, minimizing wear and tear.
  • Ease of Maintenance: Simplifies access to internal devices for inspection or replacement.
  • Cost-Effectiveness: Combines protection and functionality to extend the life of electrical systems.
Main
RangeEasy TeSys
range of productEasy TeSys Power
product or component typeCircuit breaker
Device short nameGZ1E
device applicationMotor
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to IEC 60947-1 appendix 7.1.6
ColourGrey (RAL 7011)
Complementary
Poles description3P
Network typeAC
Utilisation categoryAC-3
Network frequency50/60 Hz conforming to IEC 60947-2
mounting modeBy clips
By screws
mounting supportRail
Mounting positionAny position
Motor power kW2.2 kW at 230 V AC 50/60 Hz
4 kW at 400 V AC 50/60 Hz
4 kW at 440 V AC 50/60 Hz
5.5 kW at 500 V AC 50/60 Hz
7.5 kW at 690 V AC 50/60 Hz
Breaking capacityIcu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 2 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typePush-button
Thermal protection adjustment range6…10 A
Magnetic tripping current138 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Power dissipation2.5 W (per pole)
Mechanical durability100000 cycles
Electrical durability100000 cycles for AC-3
Maximum operating rate25 cyc/h
Connections – terminalsScrew clamp terminals 2 1…6 mm² – cable stiffness: solid
Screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible without cable end
Screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Height89 mm
Width44.5 mm
Depth78 mm
net weight0.26 kg
Environment
StandardsIEC 60947-2
IEC 60947-4
Protective treatmentTH
IP degree of protectionIP20 conforming to IEC 60529
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-1
Operating altitude2000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.800 cm
Package 1 Width8.400 cm
Package 1 Length9.000 cm
Package 1 Weight256.000 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.507 kg
Unit Type of Package 3P06
Number of Units in Package 3384
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight112.615 kg

Main documents

DatasheetDownload Datasheet
Product datasheetDownload
Instruction sheet
Download
CatalogDownload
Environmental disclosure
Download
CAD FilesDownload

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider GZ1E14 | Motor circuit breaker,Easy TeSys Power,GZ1E,AC-3,3P,6..10A,thermal magnetic trip”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat