-46%
,

Schneider LADN13 TeSys | Auxiliary contact block, TeSys D, 1NO + 3NC, front mounting, screw terminals

Schneider Electric
Availability:

In stock


Schneider LADN13 TeSys

809.51 EGP 1,499.10 EGP

In stock

Schneider LADN13 TeSys: Revolutionizing Control Systems

it is a groundbreaking innovation in the field of control systems, offering unparalleled efficiency, safety, and reliability. In this article, we will delve into the features, applications, benefits, and maintenance tips of it, shedding light on why it has become the preferred choice for various industrial and commercial applications.

1. Introduction to Schneider LADN13 TeSys

it is a part of Schneider Electric’s TeSys range, which is renowned for its superior quality and performance. It is designed to provide seamless control and protection for electrical motors, ensuring optimal efficiency and safety in diverse applications.

2. Understanding TeSys: What is it?

TeSys is a comprehensive range of motor control and protection components developed by Schneider Electric. It encompasses a wide array of products, including contactors, overload relays, starters, and accessories, aimed at optimizing motor management and enhancing operational efficiency.

1. Compact Design

One of the standout features of Schneider LADN13 TeSys is its compact and space-saving design. Despite its small size, it packs a powerful performance, making it ideal for applications where space is limited.

2. Enhanced Safety Features

Safety is paramount in industrial environments, and it is equipped with advanced safety features to ensure maximum protection for personnel and equipment. It incorporates features such as built-in overload protection and short-circuit protection, minimizing the risk of electrical hazards.

 Easy Installation

it is designed for hassle-free installation, allowing for quick and effortless integration into existing systems. Its user-friendly design and intuitive interface make it suitable for both novice and experienced users.

3. Applications of Schneider LADN13 TeSys

it finds applications across various industries and sectors, thanks to its versatility and reliability.

3.1 Industrial Machinery

In industrial settings, it is used to control and protect motors in a wide range of machinery, including pumps, conveyors, and compressors. Its robust construction and high-performance capabilities make it an indispensable component in industrial automation systems.

3.2 HVAC Systems

Heating, Ventilation, and Air Conditioning (HVAC) systems rely on precise motor control for efficient operation, and it delivers unmatched performance in this regard. It ensures smooth and reliable operation of HVAC equipment, contributing to energy savings and enhanced comfort.

3.3 Elevator Control

Elevators require precise and reliable control systems to ensure smooth and safe operation, and it meets these requirements with ease. Its advanced features and high-quality construction make it an ideal choice for elevator control applications, providing peace of mind to building owners and occupants.

4. How Schneider LADN13 TeSys Works

it operates on the principle of electromagnetic contactors, which are responsible for controlling the flow of electrical power to the motor. When a control signal is received, the contactor closes the circuit, allowing current to flow to the motor, thereby initiating its operation.

5. Benefits of Using Schneider LADN13 TeSys

5.1 Efficiency

it enhances the efficiency of motor control systems, resulting in energy savings and reduced operating costs. Its advanced design and intelligent features optimize motor performance, ensuring maximum efficiency and productivity.

5.2 Reliability

Reliability is crucial in industrial applications, and Schneider LADN13 TeSys delivers unmatched reliability and performance. Its robust construction and durable components are designed to withstand harsh operating conditions, ensuring uninterrupted operation and minimal downtime.

5.3 Cost-effectiveness

Despite its advanced features and superior performance, Schneider LADN13 TeSys remains cost-effective, offering excellent value for money. Its long-term reliability and low maintenance requirements make it a cost-effective solution for businesses seeking to optimize their operations without breaking the bank.

6. Comparison with Alternatives

When compared to alternative control systems, Schneider LADN13 TeSys stands out for its superior performance, reliability, and versatility. Its innovative design and advanced features set it apart from the competition, making it the preferred choice for discerning customers.

7. Maintenance Tips for Schneider LADN13 TeSys

To ensure optimal performance and longevity, regular maintenance of Schneider LADN13 TeSys is essential. Here are some maintenance tips to keep your system running smoothly:

  • Regularly inspect the contactor for signs of wear or damage.
  • Keep the surrounding area clean and free from dust and debris.
  • Check electrical connections for tightness and corrosion.
  • Follow manufacturer’s guidelines for lubrication and servicing.

8. Where to Purchase Schneider LADN13 TeSys

Schneider LADN13 TeSys is available for purchase from authorized Schneider Electric distributors and retailers worldwide. To find a distributor near you, visit the Schneider Electric website or contact their customer service team for assistance.

9. Customer Reviews and Testimonials

Customers who have used Schneider LADN13 TeSys rave about its performance, reliability, and ease of installation. Here are some testimonials from satisfied customers:

  • “Schneider LADN13 TeSys has transformed our manufacturing process, providing reliable motor control and protection in a compact package.”
  • “We switched to Schneider LADN13 TeSys for our HVAC system, and the difference in performance was immediately noticeable. Highly recommended!”

10. Common FAQs about Schneider LADN13 TeSys

10.1 What is the warranty period for Schneider LADN13 TeSys?

Schneider LADN13 TeSys comes with a standard warranty period of [insert warranty period here] from the date of purchase.

Main
Range TeSys
TeSys Deca
Product name TeSys Deca
Product or component type Auxiliary contact block
Device short name LADN
Range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1D
Mounting location Front
Pole contact composition 1 NO + 3 NC
Contacts operation Instantaneous
[Ue] rated operational voltage 690 V AC 25…400 Hz
[Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL
600 V conforming to CSA
[Ith] conventional free air thermal current 10 A (at 60 °C)
Standards EN/IEC 60947-5-1
GB/T 14048.5
EN 50012
UL 60947-5-1
CSA C22.2 No 60947-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
Product certifications CB Scheme
UL
CSA
CCC
EAC
UKCA
Complementary
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
Permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 ms
Protection type GG fuse 10 A
Mechanical durability 30 Mcycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections – terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable end
Tightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2
1.7 N.m – with screwdriver pozidriv No 2
Height 48 mm
Width 44 mm
Depth 42 mm
Net weight 0.05 kg
Colour Dark grey
Environment
Environmental characteristic Normal environment
IP degree of protection IP20 conforming to IEC 60529
Protective treatment TH conforming to IEC 60068
Ambient air temperature for storage -60…80 °C
Ambient air temperature for operation -5…60 °C
Operating altitude 3000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.0 cm
Package 1 Width 4.3 cm
Package 1 Length 5.2 cm
Package 1 Weight 61.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 10
Package 2 Height 5.0 cm
Package 2 Width 8.6 cm
Package 2 Length 26.2 cm
Package 2 Weight 620.0 g
Unit Type of Package 3 S03
Number of Units in Package 3 160
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 10.404 kg
Contractual warranty
Warranty 18 
Main
Range TeSys TeSys Deca
Product name TeSys Deca
Product or component type Auxiliary contact block
Device short name LADN
Range compatibility TeSys D CAD TeSys D LC1D TeSys F LC1F TeSys F CR1F TeSys Deca CAD TeSys Deca LC1D
Mounting location Front
Pole contact composition 1 NO + 3 NC
Contacts operation Instantaneous
[Ue] rated operational voltage 690 V AC 25...400 Hz
[Ie] rated operational current 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1 600 V conforming to UL 600 V conforming to CSA
[Ith] conventional free air thermal current 10 A (at 60 °C)
Standards EN/IEC 60947-5-1 GB/T 14048.5 EN 50012 UL 60947-5-1 CSA C22.2 No 60947-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
Product certifications CB Scheme UL CSA CCC EAC UKCA
Complementary
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1
Permissible short-time rating 100 A 60 °C 1 s 120 A 60 °C 500 ms 140 A 60 °C 100 ms
Protection type GG fuse 10 A
Mechanical durability 30 Mcycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections - terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable end
Tightening torque 1.7 N.m - with screwdriver flat Ø 6 mm 1.7 N.m - with screwdriver Philips No 2 1.7 N.m - with screwdriver pozidriv No 2
Height 48 mm
Width 44 mm
Depth 42 mm
Net weight 0.05 kg
Colour Dark grey
Environment
Environmental characteristic Normal environment
IP degree of protection IP20 conforming to IEC 60529
Protective treatment TH conforming to IEC 60068
Ambient air temperature for storage -60…80 °C
Ambient air temperature for operation -5…60 °C
Operating altitude 3000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.0 cm
Package 1 Width 4.3 cm
Package 1 Length 5.2 cm
Package 1 Weight 61.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 10
Package 2 Height 5.0 cm
Package 2 Width 8.6 cm
Package 2 Length 26.2 cm
Package 2 Weight 620.0 g
Unit Type of Package 3 S03
Number of Units in Package 3 160
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 10.404 kg
Contractual warranty
Warranty 18 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LADN13 TeSys | Auxiliary contact block, TeSys D, 1NO + 3NC, front mounting, screw terminals”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024