Schneider LADN20 TeSys: Revolutionizing Industrial Automation

In the world of industrial automation, efficiency, reliability, and versatility are paramount. This is where Schneider LADN20 TeSys comes into play. This article aims to explore the features, applications, benefits, and installation of the Schneider LADN20 TeSys, shedding light on its significance in the industrial landscape.

Features of Schneider LADN20 TeSys

Compact Design

One of the standout features of the Schneider LADN20 TeSys is its compact design. Despite its small size, it packs a powerful punch, making it ideal for applications where space is limited.

High Performance

The LADN20 TeSys is renowned for its high performance. With robust construction and advanced technology, it delivers consistent and reliable operation, even in the most demanding environments.

Versatility

It is compatible with a wide range of motor types and can be seamlessly integrated into various industrial systems, offering flexibility and convenience to users.

Applications

it finds its applications across diverse industrial sectors, including:

  • Industrial Automation: From conveyor systems to packaging machinery, it plays a crucial role in automating industrial processes, enhancing efficiency and productivity.
  • Control Panels: It is commonly used in control panels to control and protect motors, ensuring optimal performance and safety.
  • Motor Control: Whether it’s starting, stopping, or protecting motors, the LADN20 TeSys excels in motor control applications, providing precise and reliable operation.

Benefits of Using Schneider LADN20 TeSys

Improved Efficiency

By streamlining motor control and protection, it helps improve overall system efficiency, reducing energy consumption and downtime.

Cost-effectiveness

Despite its advanced features, the LADN20 TeSys offers excellent value for money. Its durability and longevity translate to long-term cost savings for businesses.

Reliable Performance

With Schneider Electric’s reputation for quality and reliability, users can trust the LADN20 TeSys to deliver consistent performance day in and day out, ensuring uninterrupted operation of industrial systems.

Installation Process

Installing the Schneider LADN20 TeSys is a straightforward process that can be completed in a few simple steps. Here’s a basic guide to help you get started:

  1. Preparation: Gather all the necessary tools and materials required for installation.
  2. Mounting: Securely mount the TeSys unit in the desired location, ensuring proper ventilation and accessibility.
  3. Wiring: Connect the appropriate wires according to the wiring diagram provided in the product manual.
  4. Testing: Once the installation is complete, perform a thorough test to ensure that the TeSys is functioning correctly.

Maintenance Tips

To prolong the lifespan and optimize the performance of your Schneider LADN20 TeSys, follow these maintenance tips:

  • Regularly inspect the unit for any signs of damage or wear.
  • Keep the surrounding area clean and free from debris to prevent overheating.
  • Schedule periodic maintenance checks as recommended by the manufacturer.

Troubleshooting Common Issues

Despite its reliability, occasional issues may arise with it. Here are some common problems and their solutions:

  • Overheating: Check for inadequate ventilation or excessive load on the motor.
  • Faulty Connections: Inspect the wiring for loose connections or damaged cables.
  • Tripping of Circuit Breakers: Identify and rectify any short circuits or overloads in the system.

Comparison with Alternatives

While there are several alternatives available in the market, it stands out for its superior performance, compact design, and versatility. Its robust construction and advanced features make it a preferred choice for industrial applications worldwide.

Main
Range TeSys
TeSys Deca
Product name TeSys Deca
Product or component type Auxiliary contact block
Device short name LADN
Range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1D
Mounting location Front
Pole contact composition 2 NO
Contacts operation Instantaneous
[Ue] rated operational voltage 690 V AC 25…400 Hz
[Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL
600 V conforming to CSA
[Ith] conventional free air thermal current 10 A (at 60 °C)
Standards EN/IEC 60947-5-1
GB/T 14048.5
EN 50012
UL 60947-5-1
CSA C22.2 No 60947-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
Product certifications CB Scheme
UL
CSA
CCC
EAC
UKCA
Complementary
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
Permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 ms
Protection type GG fuse 10 A
Mechanical durability 30 Mcycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections – terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable end
Tightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2
1.7 N.m – with screwdriver pozidriv No 2
Height 48 mm
Width 26 mm
Depth 42 mm
Colour Dark grey
Environment
Environmental characteristic Normal environment
IP degree of protection IP20 conforming to IEC 60529
Protective treatment TH conforming to IEC 60068
Ambient air temperature for storage -60…80 °C
Ambient air temperature for operation -5…60 °C
Operating altitude 3000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.800 cm
Package 1 Width 4.200 cm
Package 1 Length 5.200 cm
Package 1 Weight 34.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 10
Package 2 Height 2.800 cm
Package 2 Width 8.600 cm
Package 2 Length 25.600 cm
Package 2 Weight 342.000 g
Unit Type of Package 3 S03
Number of Units in Package 3 320
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 11.452 kg
Contractual warranty
Warranty 18

Main Document

Data Sheet : LADN20

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LADN20 TeSys | Auxiliary contact block, TeSys D, 2NO, front mounting, screw terminals”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024