Let's Chat
-46%
,

Schneider LC1D115B7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 115 A – 24 V AC 50/60 Hz coil

Schneider Electric
Availability:

In stock


Schneider LC1D115B7 Contactor

15,802 EGP 29,264 EGP

In stock

Compare

Schneider LC1D115B7 Contactor: Enhancing Industrial Efficiency

Contactor plays a crucial role in the operation of electrical circuits, particularly in industrial settings. Among the plethora of contactors available in the market, the Schneider LC1D115B7 Contactor stands out for its exceptional performance and reliability. In this article, we delve into the features, applications, advantages, and more of the Schneider LC1D115B7 Contactor, providing valuable insights for professionals and enthusiasts alike.

1. Introduction to Schneider LC1D115B7 Contactor

What is a contactor?

A contactor is an electromechanical device used to control the flow of electricity in a circuit. It functions similarly to a relay but is designed to handle higher current loads and is often used to switch motor loads.

Brief overview

The Schneider LC1D115B7 Contactor is a high-performance contactor manufactured by Schneider Electric, a leading global provider of energy and automation solutions. It is designed to meet the demanding requirements of industrial applications, offering reliability, durability, and efficiency.

2. Features and Specifications

Key features

  • Rated current: 115A
  • Coil voltage: 24V AC
  • Number of poles: 3
  • AC-1 and AC-3 utilization categories
  • Compact design for easy installation
  • Built-in surge suppression for enhanced safety

Technical specifications.

  • Operating voltage: Up to 690V AC
  • Frequency: 50/60Hz
  • Ambient temperature range: -25°C to +70°C
  • Degree of protection: IP20

3. Applications

Where can Schneider LC1D115B7 Contactor be used?

it finds widespread use in various industrial applications, including:

  • Motor control
  • Heating, ventilation, and air conditioning (HVAC) systems
  • Lighting control
  • Power distribution

Industrial applications.

  • Manufacturing plants
  • Commercial buildings
  • Warehouses
  • Petrochemical plants

4. Advantages

Benefits

  • High reliability: it is built to withstand harsh industrial environments, ensuring uninterrupted operation.
  • Enhanced efficiency: With its advanced design and technology, the contactor minimizes energy losses, resulting in improved efficiency.
  • Long lifespan: Schneider Electric products are known for their durability, and the LC1D115B7 Contactor is no exception, offering a long service life.

How it improves efficiency.

By providing precise control over electrical circuits, the Schneider LC1D115B7 Contactor helps optimize energy usage, leading to cost savings for industrial users. Its compact design and easy installation further contribute to operational efficiency.

5. Installation Guide

Step-by-step installation process.

  1. Ensure that the power supply is turned off.
  2. Select an appropriate mounting location for the contactor.
  3. Connect the control circuit wires to the contactor’s coil terminals.
  4. Connect the power circuit wires to the contactor’s main terminals.
  5. Securely fasten the contactor to the mounting surface.
  6. Double-check all connections before energizing the circuit.

Safety precautions.

  • Always follow the manufacturer’s instructions and safety guidelines.
  • Use appropriate personal protective equipment (PPE) when handling electrical equipment.
  • Regularly inspect the contactor for signs of wear or damage and replace if necessary.
Main
Range TeSys
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-1
AC-4
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V AC 50/60 Hz
Complementary
Motor power kW 30 kW at 220…230 V AC 50/60 Hz (AC-3)
55 kW at 380…400 V AC 50/60 Hz (AC-3)
59 kW at 415…440 V AC 50/60 Hz (AC-3)
75 kW at 500 V AC 50/60 Hz (AC-3)
80 kW at 660…690 V AC 50/60 Hz (AC-3)
65 kW at 1000 V AC 50/60 Hz (AC-3)
18.5 kW at 400 V AC 50/60 Hz (AC-4)
30 kW at 220…230 V AC 50/60 Hz (AC-3e)
55 kW at 380…400 V AC 50/60 Hz (AC-3e)
59 kW at 415…440 V AC 50/60 Hz (AC-3e)
75 kW at 500 V AC 50/60 Hz (AC-3e)
80 kW at 660…690 V AC 50/60 Hz (AC-3e)
65 kW at 1000 V AC 50/60 Hz (AC-3e)
Motor power hp 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 250 A 40 °C – 10 min for power circuit
550 A 40 °C – 1 min for power circuit
950 A 40 °C – 10 s for power circuit
1100 A 40 °C – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 250 A gG at <= 690 V coordination type 1 for power circuit
200 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signalling circuit
Average impedance 0.6 mOhm – Ith 200 A 50 Hz for power circuit
Power dissipation per pole 24 W AC-1
7.9 W AC-3
7.9 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 8 Mcycles
Electrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
0.95 Mcycles 115 A AC-3 at Ue <= 440 V
0.95 Mcycles 115 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3…0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.15 Uc (-40…55 °C):operational AC 50/60 Hz
1…1.15 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA 280…350 VA 60 Hz cos phi 0.8 (at 20 °C)
280…350 VA 50 Hz cos phi 0.8 (at 20 °C)
Hold-in power consumption in VA 2…18 VA 60 Hz cos phi 0.3 (at 20 °C)
2…18 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 3…8 W at 50/60 Hz
Operating time 6…20 ms opening
20…50 ms closing
Maximum operating rate 2400 cyc/h 60 °C
Maximum operating rate 2400 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
IEC 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product certifications UL
CSA
CCC
UKCA
CE
EAC
Marine
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height 158 mm
Width 120 mm
Depth 136 mm
Net weight 2.5 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.000 cm
Package 1 Width 18.000 cm
Package 1 Length 21.000 cm
Package 1 Weight 2.480 kg
Unit Type of Package 2 P06
Number of Units in Package 2 27
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 79.285 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1D115B7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D115B7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 115 A – 24 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024