Let's Chat
-46%

Schneider LC1D115M7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 115 A – 220 V AC 50/60 Hz coil

Schneider Electric
Availability:

In stock


Schneider LC1D115M7 Contactor

15,802 EGP 29,264 EGP

In stock

Compare

Schneider LC1D115M7 Contactor

is a crucial electrical component designed to manage the flow of electricity in various applications. It offers reliable performance and is widely used in both industrial and residential settings.

What is a contactor?

Definition

A contactor is an electromechanical switch used to control the flow of electricity in a circuit. It consists of contacts that open and close to allow or interrupt the electrical current.

Purpose

Contactors are essential for controlling high-power circuits, such as those found in industrial machinery, HVAC systems, and electrical distribution panels.

Features of Schneider LC1D115M7 Contactor

Specifications

The Schneider LC1D115M7 Contactor is designed to handle up to 115 amps of current, making it suitable for a wide range of applications. It operates on a voltage of 240 volts AC and has a coil voltage of 24 volts AC.

Design

The contactor features a compact and durable design, with high-quality materials that ensure longevity and reliability. It is built to withstand harsh operating conditions and offers excellent performance even in demanding environments.

Applications

Industrial use

The Schneider LC1D115M7 Contactor is commonly used in industrial applications such as motor control, conveyor systems, and manufacturing equipment. Its robust construction and high current handling capabilities make it ideal for heavy-duty use.

Residential use

In residential settings, the Schneider LC1D115M7 Contactor is often used in appliances like air conditioners, refrigerators, and water heaters. It helps to control the flow of electricity and ensures the safe operation of household devices.

Benefits

One of the primary benefits of the Schneider LC1D115M7 Contactor is its efficiency. By effectively controlling the flow of electricity, it helps to optimize the performance of electrical systems and reduce energy consumption.

Safety

Safety is paramount when working with electrical systems,  ensures safe operation by providing reliable switching and isolation of circuits. It helps to prevent electrical accidents and minimize the risk of damage to equipment and personnel.

Installation and Maintenance Guide

Installation process

Installing the Schneider LC1D115M7 Contactor is relatively straightforward, but it requires careful attention to detail to ensure proper operation. The contactor should be mounted securely and wired according to the manufacturer’s instructions.

Maintenance tips

Regular maintenance is essential to keep the Schneider LC1D115M7 Contactor in optimal condition. This includes inspecting the contacts for signs of wear or damage, checking for loose connections, and cleaning the contactor as needed to remove dust and debris.

How to Choose the Right Schneider Contactor

Considerations

When choosing a Schneider contactor, it’s important to consider factors such as the maximum current rating, voltage rating, coil voltage, and mounting type. These specifications will vary depending on the specific requirements of your application.

Comparison with other models

Schneider offers a range of contactors with different features and capabilities. Comparing the LC1D115M7 Contactor with other models can help you determine which one best suits your needs based on factors such as price, performance, and compatibility.

Common Issues and Troubleshooting

Troubleshooting steps

If you encounter issues with the Schneider LC1D115M7 Contactor, there are several troubleshooting steps you can take to identify and resolve the problem. These may include checking for loose connections, testing the coil voltage, and inspecting the contacts for damage.

Common issues

Some common issues that may arise with the Schneider LC1D115M7 Contactor include overheating, contact welding, and coil failure. Understanding these potential problems can help you address them quickly and prevent further damage to the contactor or connected equipment.

Conclusion

The Schneider LC1D115M7 Contactor is a versatile and reliable electrical component that offers excellent performance in a wide range of applications. Its robust construction, efficient operation, and safety features make it an ideal choice for both industrial and residential use.

Main
Range TeSys
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Complementary
Motor power kW 30 kW at 220…230 V AC 50/60 Hz (AC-3)
55 kW at 380…400 V AC 50/60 Hz (AC-3)
59 kW at 415…440 V AC 50/60 Hz (AC-3)
75 kW at 500 V AC 50/60 Hz (AC-3)
80 kW at 660…690 V AC 50/60 Hz (AC-3)
65 kW at 1000 V AC 50/60 Hz (AC-3)
18.5 kW at 400 V AC 50/60 Hz (AC-4)
30 kW at 220…230 V AC 50/60 Hz (AC-3e)
55 kW at 380…400 V AC 50/60 Hz (AC-3e)
59 kW at 415…440 V AC 50/60 Hz (AC-3e)
75 kW at 500 V AC 50/60 Hz (AC-3e)
80 kW at 660…690 V AC 50/60 Hz (AC-3e)
65 kW at 1000 V AC 50/60 Hz (AC-3e)
Motor power hp 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 250 A 40 °C – 10 min for power circuit
550 A 40 °C – 1 min for power circuit
950 A 40 °C – 10 s for power circuit
1100 A 40 °C – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 250 A gG at <= 690 V coordination type 1 for power circuit
200 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signalling circuit
Average impedance 0.6 mOhm – Ith 200 A 50 Hz for power circuit
Power dissipation per pole 24 W AC-1
7.9 W AC-3
7.9 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 8 Mcycles
Electrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
0.95 Mcycles 115 A AC-3 at Ue <= 440 V
0.95 Mcycles 115 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3…0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.15 Uc (-40…55 °C):operational AC 50/60 Hz
1…1.15 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA 280…350 VA 60 Hz cos phi 0.8 (at 20 °C)
280…350 VA 50 Hz cos phi 0.8 (at 20 °C)
Hold-in power consumption in VA 2…18 VA 60 Hz cos phi 0.3 (at 20 °C)
2…18 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 3…8 W at 50/60 Hz
Operating time 6…20 ms opening
20…50 ms closing
Maximum operating rate 2400 cyc/h 60 °C
Maximum operating rate 2400 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
IEC 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product certifications UL
CSA
CCC
UKCA
CE
EAC
Marine
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height 158 mm
Width 120 mm
Depth 136 mm
Net weight 2.5 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.000 cm
Package 1 Width 16.800 cm
Package 1 Length 20.500 cm
Package 1 Weight 2.499 kg
Unit Type of Package 2 S06
Number of Units in Package 2 27
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 79.663 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1D115M7 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D115M7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 115 A – 220 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024