Schneider LC1D128B7 Contactor: Powering Your Industrial Solutions

In the realm of industrial automation, precision and reliability are paramount. This is where the Schneider LC1D128B7 contactor shines. As a crucial component in electrical systems, this contactor plays a pivotal role in ensuring seamless operations across various industries.

Understanding Contactor Basics

What is a contactor?

A contactor is an electromechanical device used to make or break electrical connections. It is essentially a switch that is controlled by an electromagnet, allowing it to handle high currents and voltages.

Purpose and function of a contactor

Contactor’s primary function is to control the flow of electricity in an electrical circuit. It enables the control of motors, lighting systems, heating elements, and other electrical loads.

Features and Specifications

Overview of Schneider LC1D128B7

The Schneider LC1D128B7 is a high-performance contactor designed to meet the demanding requirements of industrial applications. It boasts robust construction, advanced technology, and exceptional reliability.

Key features

  • High current and voltage rating
  • Compact design
  • Low power consumption
  • Built-in overload protection
  • Wide operating temperature range

Technical specifications

  • Rated operational current: 128A
  • Rated operational voltage: Up to 690V
  • Coil voltage: 24V AC

Applications and Industries

Where is Schneider LC1D128B7 used?

it finds widespread use across various industries, including:

  • Manufacturing
  • Automotive
  • Chemical
  • Oil and gas
  • Mining

Industrial applications

  • Motor control
  • Lighting systems
  • HVAC systems
  • Power distribution

Advantages

Efficiency and reliability

The Schneider LC1D128B7 excels in terms of efficiency and reliability. Its robust design ensures long-term performance even in harsh industrial environments.

Safety features

Safety is paramount in industrial settings, and the Schneider LC1D128B7 doesn’t disappoint. It comes equipped with built-in overload protection and meets stringent safety standards.

Easy installation and maintenance

Installing and maintaining the Schneider LC1D128B7 is a breeze, thanks to its user-friendly design. It simplifies the process, saving time and effort for technicians.

Comparison with Competitors

How does it compare with other contactors?

In comparison to its competitors, the Schneider LC1D128B7 stands out due to its superior performance, reliability, and advanced features.

Strengths and weaknesses

  • Strengths: High durability, wide voltage range, overload protection
  • Weaknesses: Slightly higher cost compared to some competitors

Installation and Maintenance Guide

Step-by-step installation process

  1. Mount the contactor securely on a suitable surface.
  2. Connect the control circuit wires to the appropriate terminals.
  3. Connect the power supply wires to the main terminals.
  4. Test the contactor to ensure proper operation.

Maintenance tips and best practices

  • Regularly inspect for signs of wear or damage.
  • Clean the contactor contacts to ensure optimal conductivity.
  • Check and tighten terminal connections periodically.

Troubleshooting Common Issues

Identifying common problems

  • Contact welding
  • Coil failure
  • Overheating

Solutions and fixes

  • Clean contacts or replace if necessary.
  • Check and replace the coil if defective.
  • Ensure proper ventilation to prevent overheating.
  • Pros: Robust construction, easy installation, reliable performance
  • Cons: Slightly higher initial cost compared to some alternatives

Pricing and Availability

Cost considerations

The Schneider LC1D128B7 is competitively priced considering its advanced features and performance.

Where to purchase Schneider LC1D128B7

The contactor is available through authorized distributors and online retailers, ensuring easy accessibility for customers worldwide.

Main
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
AC-3
AC-3e
AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 24 V AC 50/60 Hz
Complementary
Compatibility code LC1D
Pole contact composition 2 NO + 2 NC
Protective cover With
[Ith] conventional free air thermal current 25 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 105 A 40 °C – 10 s for power circuit
210 A 40 °C – 1 s for power circuit
30 A 40 °C – 10 min for power circuit
61 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm – Ith 25 A 50 Hz for power circuit
Power dissipation per pole 1.56 W AC-1
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 0.8 Mcycles 25 A AC-1 at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz
Operating time 12…22 ms closing
4…19 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Tightening torque Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1
Product certifications UL
CCC
CSA
Marine
UKCA
EAC
CB Scheme
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor open (10 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
Height 85 mm
Width 45 mm
Depth 92 mm
Net weight 0.365 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.500 cm
Package 1 Width 9.500 cm
Package 1 Length 12.000 cm
Package 1 Weight 394.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 16
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 6.862 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1D128B7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D128B7 Contactor | TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 – <= 440 V 25 A – 24 V AC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024