-46%

Schneider LC1D12B7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 12 A – 24 V AC coil

Schneider Electric
Availability:

In stock


Schneider LC1D12B7 Contactor

1,548.23 EGP 2,867.10 EGP

In stock

Compare

Schneider LC1D12B7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – &lt;= 440 V 12 A – 24 V AC coil

Schneider LC1D12B7 Contactor: Enhancing Electrical Systems

is a crucial component in electrical systems, known for its reliability, efficiency, and safety features. In this article, we will delve into the details of Schneider LC1D12B7 Contactor, exploring its features, applications, advantages, installation guide, maintenance tips, customer reviews, and more.

Understanding the Purpose of a Contactor

What is a contactor?

A contactor is an electromechanical device used to make or break electrical connections. It is primarily designed to control electric motors and power circuits.

Importance of contactors in electrical systems

Contactors play a vital role in ensuring the smooth operation of electrical systems by managing the flow of electricity to various components and machinery.

Features of Schneider LC1D12B7 Contactor

Specifications

is designed for use in AC-3 applications up to 440V. It has a rated operational current of 12A and a coil voltage of 24V AC.

Design and build

The contactor features a compact and robust design, making it suitable for diverse industrial applications. It is built to withstand high levels of electrical stress and environmental conditions.

Compatibility

The Schneider LC1D12B7 Contactor is compatible with a wide range of electrical systems, offering versatility and ease of integration.

Applications 

Schneider LC1D12B7 Contactor finds extensive use in various industries and applications, including:

  • Industrial machinery: Such as pumps, conveyors, and compressors.
  • HVAC systems: For controlling heating, ventilation, and air conditioning equipment.
  • Elevators and escalators: Ensuring smooth and reliable operation of vertical transportation systems.

Advantages 

Reliability

Schneider LC1D12B7 Contactor is renowned for its reliability, providing consistent performance even in demanding environments.

Efficiency

The contactor offers efficient operation, minimizing energy wastage and optimizing the performance of electrical systems.

Safety features

With built-in safety features such as overload protection and arc suppression, Schneider LC1D12B7 Contactor ensures the safety of both equipment and personnel.

Installation Guide 

Precautions

Before installing the contactor, ensure that the power supply is disconnected to prevent any accidents or injuries.

Step-by-step installation process

  1. Mount the contactor securely on a suitable surface using the provided mounting holes.
  2. Connect the control circuit wires to the appropriate terminals as per the wiring diagram.
  3. Connect the power supply wires to the main terminals of the contactor.
  4. Verify the connections and tighten the terminal screws to ensure proper contact.
  5. Reconnect the power supply and test the operation of the contactor.
Main
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Motor control
Utilisation categoryAC-3
AC-1
AC-4
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage24 V AC 50/60 Hz
Complementary
Motor power kW3 kW at 220…230 V AC 50/60 Hz (AC-3)
5.5 kW at 380…400 V AC 50/60 Hz (AC-3)
5.5 kW at 415…440 V AC 50/60 Hz (AC-3)
7.5 kW at 500 V AC 50/60 Hz (AC-3)
7.5 kW at 660…690 V AC 50/60 Hz (AC-3)
3.7 kW at 400 V AC 50/60 Hz (AC-4)
3 kW at 220…230 V AC 50/60 Hz (AC-3e)
5.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
5.5 kW at 415…440 V AC 50/60 Hz (AC-3e)
7.5 kW at 500 V AC 50/60 Hz (AC-3e)
7.5 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
3 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 230/240 V AC 50/60 Hz for 3 phases motors
7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
10 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current25 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
Irms rated making capacity250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current105 A 40 °C – 10 s for power circuit
210 A 40 °C – 1 s for power circuit
30 A 40 °C – 10 min for power circuit
61 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuit
Average impedance2.5 mOhm – Ith 25 A 50 Hz for power circuit
Power dissipation per pole0.36 W AC-3
1.56 W AC-1
0.36 W AC-3e
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability2 Mcycles 12 A AC-3 at Ue <= 440 V
0.8 Mcycles 25 A AC-1 at Ue <= 440 V
2 Mcycles 12 A AC-3e at Ue <= 440 V
Control circuit typeAC at 50/60 Hz standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time12…22 ms closing
4…19 ms opening
Maximum operating rate3600 cyc/h 60 °C
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsPower circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Tightening torquePower circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportRail
Plate
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1
Product certificationsUL
CCC
CSA
Marine
UKCA
EAC
CB Scheme
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor open (10 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
Height77 mm
Width45 mm
Depth86 mm
Net weight0.325 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width9.200 cm
Package 1 Length11.200 cm
Package 1 Weight359.000 g
Unit Type of Package 2S02
Number of Units in Package 220
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.503 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LC1D12B7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D12B7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 12 A – 24 V AC coil”