Let's Chat
-46%
,

Schneider LC1D12Q7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 12 A – 380 V AC coil

Schneider Electric
Availability:

In stock


Schneider LC1D12Q7 Contactor

1,548 EGP 2,867 EGP

In stock

Compare

Schneider LC1D12Q7 Contactor: Enhancing Electrical Control

is a vital component in electrical systems, playing a crucial role in controlling the flow of electricity. Whether you’re a seasoned electrician or a DIY enthusiast, understanding the ins and outs of this contactor can significantly benefit your projects. In this comprehensive guide, we’ll delve into the features, installation process, benefits, applications, maintenance, and troubleshooting of the Schneider LC1D12Q7 Contactor.

Understanding the Functionality of Contactors

Contactors are electromechanical switches designed to control the flow of electricity in a circuit. They consist of a coil, contacts, and an enclosure. When energized, the coil generates a magnetic field, attracting the contacts and closing the circuit. Conversely, when the coil is de-energized, the contacts open, interrupting the flow of electricity.

Features and Specifications of Schneider LC1D12Q7 Contactor

The Schneider LC1D12Q7 Contactor boasts a myriad of features tailored for optimal performance and reliability. With a rated operational current of 12A and a coil voltage of 24VAC, this contactor is suitable for a wide range of applications. Its compact design and DIN rail mounting make installation a breeze, saving time and effort for electricians.

Installation Guide

is straightforward, provided you adhere to the manufacturer’s guidelines. Begin by ensuring the power supply is disconnected to prevent any accidents. Mount the contactor on a suitable surface using the designated mounting holes. Next, wire the control circuit to the contactor following the wiring diagram provided in the manual. Once everything is connected, restore power and test the functionality of the contactor.

Benefits

The Schneider LC1D12Q7 Contactor offers several benefits, making it a preferred choice for electrical contractors and engineers. Its reliable performance ensures smooth operation, reducing downtime and maintenance costs. Additionally, its compact design saves valuable space in electrical panels, making it ideal for applications with limited real estate.

Common Applications

From industrial machinery to HVAC systems, the Schneider LC1D12Q7 Contactor finds widespread use across various industries. Its versatility and robust construction make it suitable for controlling motors, pumps, compressors, and lighting circuits. Whether you’re building a new facility or upgrading an existing one, this contactor is sure to meet your electrical control needs.

Maintenance Tips for Schneider LC1D12Q7 Contactor

To ensure optimal performance and longevity, regular maintenance of the Schneider LC1D12Q7 Contactor is essential. Periodically inspect the contacts for signs of wear or corrosion and clean them if necessary. Tighten any loose connections and replace damaged components promptly. Lubricate moving parts to prevent friction and ensure smooth operation.

Troubleshooting Guide for Schneider LC1D12Q7 Contactor

In the event of malfunctions or operational issues, refer to the troubleshooting guide provided in the user manual. Common problems such as contact welding or coil failure can often be resolved with simple troubleshooting steps. If the issue persists, contact Schneider Electric’s customer support for assistance.

Safety Measures Associated with Schneider LC1D12Q7 Contactor

When working with electrical equipment, safety should always be a top priority. Before handling the Schneider LC1D12Q7 Contactor, ensure the power supply is disconnected and follow proper lockout/tagout procedures. Wear appropriate personal protective equipment, such as insulated gloves and safety glasses, to prevent accidents.

Comparison with Other Contactor Models

To help you make an informed decision, compare the Schneider LC1D12Q7 Contactor with other models available in the market. Consider factors such as price, features, reliability, and customer reviews to determine which contactor best suits your requirements.

Main
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-1
AC-4
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 380 V AC 50/60 Hz
Complementary
Motor power kW 3 kW at 220…230 V AC 50/60 Hz (AC-3)
5.5 kW at 380…400 V AC 50/60 Hz (AC-3)
5.5 kW at 415…440 V AC 50/60 Hz (AC-3)
7.5 kW at 500 V AC 50/60 Hz (AC-3)
7.5 kW at 660…690 V AC 50/60 Hz (AC-3)
3.7 kW at 400 V AC 50/60 Hz (AC-4)
3 kW at 220…230 V AC 50/60 Hz (AC-3e)
5.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
5.5 kW at 415…440 V AC 50/60 Hz (AC-3e)
7.5 kW at 500 V AC 50/60 Hz (AC-3e)
7.5 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
3 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 230/240 V AC 50/60 Hz for 3 phases motors
7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
10 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 25 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 105 A 40 °C – 10 s for power circuit
210 A 40 °C – 1 s for power circuit
30 A 40 °C – 10 min for power circuit
61 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm – Ith 25 A 50 Hz for power circuit
Power dissipation per pole 0.36 W AC-3
1.56 W AC-1
0.36 W AC-3e
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 2 Mcycles 12 A AC-3 at Ue <= 440 V
0.8 Mcycles 25 A AC-1 at Ue <= 440 V
2 Mcycles 12 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz
Operating time 12…22 ms closing
4…19 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Tightening torque Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1
Product certifications UL
CCC
CSA
Marine
UKCA
EAC
CB Scheme
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor open (10 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
Height 77 mm
Width 45 mm
Depth 86 mm
Net weight 0.325 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.000 cm
Package 1 Width 9.200 cm
Package 1 Length 11.200 cm
Package 1 Weight 352.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 20
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 7.334 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet LC1D12Q7 
Instruction sheet
Download
Catalogue
Download
CAD Files
Download
Environmental disclosure Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D12Q7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 12 A – 380 V AC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024