-46%
,

Schneider LC1D18F7 | contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 110 V AC coil

Schneider Electric
Availability:

In stock


Schneider LC1D18F7

1,938 EGP 3,590 EGP

In stock

Compare

Exploring the Schneider LC1D18F7: A Comprehensive Guide

Introduction

Schneider Electric, a renowned name in the realm of electrical solutions, is synonymous with innovation and reliability. Quality electrical components are paramount for ensuring safety and efficiency in various applications. In this article, we delve into one such component, it, to understand its features, applications, and benefits.

Understanding the Schneider LC1D18F7

it is an electrical contactor designed to meet diverse electrical control requirements. Let’s explore its key characteristics.

General Description

it is known for its robust build and efficient operation. It serves as a critical component in electrical circuits, providing reliable switching functionality.

Key Features

  • High Performance: Engineered to deliver consistent performance in demanding conditions.
  • Compact Design: Occupies minimal space while offering optimal functionality.
  • Enhanced Safety: Equipped with features to ensure safe operation and protect against overloads.

Specifications of the Schneider LC1D18F7

Understanding the technical specifications is essential for proper utilization of it.

Technical Details

  • Voltage Rating: [Insert Voltage Rating]
  • Current Rating: [Insert Current Rating]
  • Operating Temperature: [Insert Temperature Range]

Dimensions and Weight

  • Height: [Insert Height]
  • Width: [Insert Width]
  • Depth: [Insert Depth]
  • Weight: [Insert Weight]

Applications of Schneider LC1D18F7

The versatility of the Schneider LC1D18F7 allows it to be employed in various settings.

Residential Applications

Used in residential electrical systems for controlling lighting, heating, and other appliances.

Commercial Applications

Suitable for controlling electrical loads in commercial buildings, offices, and retail spaces.

Industrial Applications

Capable of handling heavy-duty electrical loads in industrial settings, including manufacturing plants and warehouses.

Advantages of Using Schneider LC1D18F7

Opting for it offers several benefits.

Durability

Built to withstand prolonged use and harsh operating conditions, ensuring longevity.

Efficiency

Facilitates efficient control of electrical loads, optimizing energy consumption.

Safety Features

Incorporates safety mechanisms to prevent overheating and electrical hazards.

Installation Guide

Proper installation is crucial for maximizing the performance of it.

Pre-installation Preparations

Gather all necessary tools and equipment. Ensure compliance with electrical codes and regulations.

Step-by-Step Installation Process

  1. Power Off: Disconnect power supply to the circuit.
  2. Mounting: Securely mount it in the designated location.
  3. Wiring: Follow wiring diagrams provided by Schneider Electric for correct connections.
  4. Testing: Verify proper installation and functionality before restoring power.

Post-installation Recommendations

Regularly inspect it for signs of wear and tear. Keep the surrounding area clean and free from obstructions.

Maintenance and Troubleshooting

Regular maintenance helps ensure optimal performance and longevity of it.

Regular Maintenance Guidelines

  • Inspect for loose connections and signs of overheating.
  • Clean the contactor and surrounding area to prevent debris accumulation.
  • Test functionality periodically to identify any issues early on.

Common Issues and Solutions

  • Overheating: Ensure proper ventilation and check for overloading.
  • Faulty Connections: Tighten connections and inspect for corrosion.
  • Operational Failures: Verify power supply and wiring integrity.

Comparative Analysis

Comparing it with similar models provides valuable insights.

Schneider LC1D18F7 vs. Similar Models

Highlight the unique features and advantages of it over competing models.

Advantages Over Competitors

Emphasize the superior performance, durability, and safety features of it.

Main
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
contactor applicationMotor control
Resistive load
utilisation categoryAC-1
AC-4
AC-3
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage110 V AC 50/60 Hz
Complementary
Motor power kW4 kW at 220…230 V AC 50/60 Hz (AC-3)
7.5 kW at 380…400 V AC 50/60 Hz (AC-3)
9 kW at 415…440 V AC 50/60 Hz (AC-3)
10 kW at 500 V AC 50/60 Hz (AC-3)
10 kW at 660…690 V AC 50/60 Hz (AC-3)
4 kW at 400 V AC 50/60 Hz (AC-4)
4 kW at 220…230 V AC 50/60 Hz (AC-3e)
7.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
9 kW at 415…440 V AC 50/60 Hz (AC-3e)
10 kW at 500 V AC 50/60 Hz (AC-3e)
10 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp1 hp at 115 V AC 50/60 Hz for 1 phase motors
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
10 hp at 460/480 V AC 50/60 Hz for 3 phases motors
15 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
32 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
300 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current145 A 40 °C – 10 s for power circuit
240 A 40 °C – 1 s for power circuit
40 A 40 °C – 10 min for power circuit
84 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
50 A gG at <= 690 V coordination type 1 for power circuit
35 A gG at <= 690 V coordination type 2 for power circuit
Average impedance2.5 mOhm – Ith 32 A 50 Hz for power circuit
Power dissipation per pole2.5 W AC-1
0.8 W AC-3
0.8 W AC-3e
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability1.65 Mcycles 18 A AC-3 at Ue <= 440 V
1 Mcycles 32 A AC-1 at Ue <= 440 V
1.65 Mcycles 18 A AC-3e at Ue <= 440 V
Control circuit typeAC at 50/60 Hz standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time12…22 ms closing
4…19 ms opening
Maximum operating rate3600 cyc/h 60 °C
Connections – terminalsControl circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: solid without cable end
Tightening torquePower circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typeType mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
mounting supportPlate
Rail
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
product certificationsGL
RINA
UL
CCC
DNV
LROS (Lloyds register of shipping)
CSA
GOST
BV
UKCA
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandConforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor open (10 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
height77 mm
Width45 mm
Depth86 mm
Net weight0.33 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.2 cm
Package 1 Width9.2 cm
Package 1 Length11.2 cm
Package 1 Weight356.0 g
Unit Type of Package 2S02
Number of Units in Package 220
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight7.52 kg
Unit Type of Package 3P06
Number of Units in Package 3320
Package 3 Height80.0 cm
Package 3 Width80.0 cm
Package 3 Length60.0 cm
Package 3 Weight129.3 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LC1D18F7

Based on 0 reviews