Schneider LC1D258B7 Contactor | TeSys D – 4P (2NO + 2NC) – AC-1 – ≤ 440V 40A – 24V AC Coil

1. Overview

The Schneider LC1D258B7 is a 4-pole contactor from the TeSys D series, featuring 2 Normally Open (2NO) and 2 Normally Closed (2NC) contacts. It is designed for AC-1 category applications, making it ideal for resistive load switching up to 40A at ≤ 440V. The 24V AC coil ensures reliable performance in low-voltage control circuits, making it suitable for industrial and commercial electrical systems.

2. Key Features

  • Brand: Schneider Electric

  • Series: TeSys D

  • Model: LC1D258B7

  • Type: Contactor

  • Number of Poles: 4 (2NO + 2NC)

  • Utilization Category: AC-1 (Resistive loads)

  • Voltage Rating: ≤ 440V

  • Current Rating: 40A

  • Coil Voltage: 24V AC

  • Control Circuit Frequency: 50/60Hz

  • Electrical Durability: Designed for high switching endurance

  • Connection Type: Screw clamp terminals for secure and easy wiring

  • Mounting: DIN rail or panel mount for flexible installation

3. Benefits

  • Reliable Switching: Designed for efficient and consistent operation in industrial environments.

  • Energy-Efficient Coil: The 24V AC coil provides low power consumption and stable operation.

  • Compact and Modular Design: Saves space in electrical panels and enclosures.

  • Easy Installation & Maintenance: Screw clamp terminals allow quick and secure wiring.

  • Versatile Load Control: Handles AC-1 category applications with a 40A rating.

4. Applications

  • Industrial Automation: Controls resistive and inductive loads in manufacturing and processing industries.

  • Lighting Control: Used for switching large lighting circuits in commercial buildings.

  • Heating Systems: Manages electric heating and boiler controls.

  • Power Distribution: Provides reliable switching in electrical distribution panels.

  • HVAC Systems: Ensures smooth operation of heating, ventilation, and air conditioning units.

5. Conclusion

The Schneider LC1D258B7 TeSys D Contactor is a high-performance, space-efficient, and durable solution for general-purpose power control applications. With its 4-pole (2NO + 2NC) configuration, 40A rating, and 24V AC coil, it offers efficient and reliable switching for industrial, commercial, and residential electrical systems.

Main
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
AC-3
AC-3e
AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
[Ie] rated operational current 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 24 V AC 50/60 Hz
Complementary
Compatibility code LC1D
Pole contact composition 2 NO + 2 NC
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 240 A 40 °C – 10 s for power circuit
380 A 40 °C – 1 s for power circuit
50 A 40 °C – 10 min for power circuit
120 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2 mOhm – Ith 40 A 50 Hz for power circuit
Power dissipation per pole 3.2 W AC-1
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 1.4 Mcycles 40 A AC-1 at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…60 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz
Operating time 12…22 ms closing
4…19 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…16 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 1.8 N.m – on screw clamps terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.8 N.m – on screw clamps terminals – with screwdriver Philips No 2
Power circuit: 1.8 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1
Product certifications UL
CCC
CSA
Marine
UKCA
EAC
CB Scheme
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
Height 91 mm
Width 45 mm
Depth 99 mm
Net weight 0.425 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.800 cm
Package 1 Width 9.500 cm
Package 1 Length 12.000 cm
Package 1 Weight 475.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 16
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 8.086 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D258B7 Contactor | TeSys D- 4P(2 NO + 2 NC) – AC-1 – <= 440 V 40 A – 24 V AC coil”

There are no reviews yet.

SHOPPING CART

close
Let's Chat