-48%

Schneider LC1D258Q7 | Contactor, TeSys Deca, 4P(2NO+2NC), AC-1, <=440V, 40A, 380V AC 50/60Hz coil, screw clamp terminal

Schneider Electric
Availability:

In stock


Schneider LC1D258Q7 | Contactor, TeSys Deca, 4P(2NO+2NC), AC-1, <=440V, 40A, 380V AC 50/60Hz coil, screw clamp terminal

2,805 EGP 5,395 EGP

In stock

Compare

Schneider LC1D258Q7 | Contactor, TeSys Deca, 4P(2NO+2NC), AC-1, <=440V, 40A, 380V AC 50/60Hz coil, screw clamp terminal

Schneider LC1D258Q7: The Ultimate Guide

Introduction

In the realm of industrial automation, reliable components are the backbone of efficient operations. One such crucial component is it contactor. This device plays a pivotal role in controlling electrical circuits, making it indispensable in various industrial applications.

What is the Schneider LC1D258Q7?

it is an advanced contactor designed to control electric motors and other high-power loads. Known for its durability and efficiency, this contactor is a part of Schneider Electric’s renowned product lineup. Key specifications include:

  • Rated Operational Voltage: Up to 690V
  • Conventional Free Air Thermal Current: 80A
  • Utilization Category: AC-3

Applications of Schneider LC1D258Q7

it is versatile and finds applications in several areas:

  • Industrial Automation: Ensures seamless operation of machinery and equipment.
  • Motor Control: Facilitates efficient control of electric motors.
  • HVAC Systems: Integral in heating, ventilation, and air conditioning systems for precise control.

Key Features of Schneider LC1D258Q7

it stands out due to its impressive features:

  • High Reliability: Designed to withstand rigorous industrial environments.
  • Compact Design: Saves space in electrical panels.
  • Energy Efficiency: Helps in reducing energy consumption, contributing to cost savings.

Technical Specifications

Understanding the technical aspects of it is crucial for optimal use:

  • Electrical Specifications:
    • Rated insulation voltage: 690V
    • Control circuit voltage: 24V to 415V
  • Mechanical Specifications:
    • Contact composition: 3NO + 2NC
    • Mechanical durability: 10 million operations
  • Environmental Specifications:
    • Operating temperature range: -25°C to 60°C
    • Degree of protection: IP20

Installation and Setup

Proper installation ensures the longevity and performance of the Schneider LC1D258Q7:

  • Pre-installation Considerations: Verify voltage requirements and ensure proper grounding.
  • Step-by-Step Installation Guide:
    1. Turn off the main power supply.
    2. Mount the contactor on a DIN rail.
    3. Connect the control circuit wires.
    4. Secure the power wires to the contactor terminals.
    5. Check all connections and restore power.

Advantages of Using Schneider LC1D258Q7

Choosing it brings several benefits:

  • Efficiency in Operations: Reduces downtime and enhances productivity.
  • Durability and Longevity: Built to last, ensuring a long service life.
  • Cost-Effectiveness: Low maintenance and high efficiency lead to cost savings.
SKU: LC1D258Q7 Category:
Main
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
contactor applicationResistive load
Utilisation categoryAC-1
AC-3
AC-3e
AC-4
poles description4P
[Ue] rated operational voltagePower circuit <= 690 V AC 25…400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current40 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage380 V AC 50/60 Hz
Complementary
Compatibility codeLC1D
Pole contact composition2 NO + 2 NC
Protective coverWith
[Ith] conventional free air thermal current10 A (at 140 °F (60 °C)) for signalling circuit
40 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current240 A 104 °F (40 °C) – 10 s for power circuit
380 A 104 °F (40 °C) – 1 s for power circuit
50 A 104 °F (40 °C) – 10 min for power circuit
120 A 104 °F (40 °C) – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
Average impedance2 mOhm – Ith 40 A 50 Hz for power circuit
Power dissipation per pole3.2 W AC-1
[Ui] rated insulation voltagePower circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability1.4 Mcycles 40 A AC-1 <= 440 V
Control circuit typeAC 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8…1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz
0.85…1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz
1…1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
70 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
7 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation2…3 W at 50/60 Hz
Operating time12…22 ms closing
4…19 ms opening
Maximum operating rate3600 cyc/h 140 °F (60 °C)
Connections – terminalsControl circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…10 mm²) – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 0.004…0.02 in² (2.5…16 mm²) – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…16 mm²) – cable stiffness: solid without cable end
Tightening torqueControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 15.9 lbf.in (1.8 N.m) screw clamps terminals flat Ø 6 mm
Power circuit 15.9 lbf.in (1.8 N.m) screw clamps terminals Philips No 2
Power circuit 15.9 lbf.in (1.8 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typeMechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportPlate
Rail
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certificationsGL
BV
DNV
LROS (Lloyds register of shipping)
RINA
UL
CCC
CSA
GOST
UKCA
CB
IP degree of protectionIP20 front face IEC 60529
Protective treatmentTHIEC 60068-2-30
Climatic withstandIACS E10 exposure to damp heat
IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…140 °F (-40…60 °C)
140…158 °F (60…70 °C) with derating
Operating altitude0…3000 m
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 UL 94
Mechanical robustnessVibrations contactor open 2 Gn, 5…300 Hz)
Vibrations contactor closed 4 Gn, 5…300 Hz)
Shocks contactor closed 15 Gn for 11 ms)
Shocks contactor open 8 Gn for 11 ms)
Height3.6 in (91 mm)
Width1.8 in (45 mm)
Depth3.9 in (99 mm)
Net weight0.937 lb(US) (0.425 kg)
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height3.57 in (9.08 cm)
Package 1 Width1.8 in (4.5 cm)
Package 1 Length3.92 in (9.95 cm)
Package 1 Weight15.3 oz (435.0 g)
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0