-46%

Schneider LC1D25M7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 25 A – 220 V AC coil

Schneider Electric
Availability:

In stock


Schneider LC1D25M7

2,506 EGP 4,641 EGP

In stock

Compare

Schneider LC1D25M7

Introduction

In the world of electrical control systems, it stands out as a crucial component. This guide will explore its significance, features, applications, and much more, offering a thorough understanding of why this device is essential in various electrical setups.

Overview of Schneider Electric

Schneider Electric, a renowned leader in energy management and automation, has a long history of innovation and excellence. With roots dating back to the 19th century, the company is dedicated to providing efficient, reliable, and sustainable solutions for a wide range of industries.

Understanding the Schneider LC1D25M7

Technical Specifications

it is known for its robust technical specifications. Key specs include:

  • Voltage Rating: Up to 690V
  • Current Rating: 25A
  • Operating Frequency: 50/60 Hz
  • Contact Configuration: 3PST (3 Pole Single Throw)

Key Features

  • High Durability: Designed to withstand harsh industrial environments.
  • Compact Design: Easy to integrate into various systems.
  • Energy Efficiency: Reduces energy consumption, making it eco-friendly.
  • Advanced Safety Features: Includes protections against overload and short circuits.

Applications of Schneider LC1D25M7

Residential Uses

In homes, it ensures the smooth operation of electrical systems, enhancing safety and efficiency. It’s ideal for managing circuits and household appliances.

Commercial Uses

For businesses, this contactor supports various electrical needs, from lighting systems to HVAC units. It boosts operational efficiency and reduces energy costs, making it a valuable asset for commercial properties.

Industrial Uses

Industries depend on reliable electrical systems to operate heavy machinery and complex processes. it offers the robustness and reliability needed for such demanding applications.

Installation Process

Step-by-Step Guide

  1. Preparation: Gather all necessary tools and components.
  2. Safety First: Ensure the power is disconnected before starting.
  3. Mounting: Secure the contactor in the designated location.
  4. Wiring: Connect the wires as per the installation manual.
  5. Testing: Reconnect power and test the system for proper functionality.

Safety Precautions

  • Always adhere to the manufacturer’s guidelines.
  • Use protective gear such as gloves and safety glasses.
  • Verify all connections to avoid electrical hazards.

Benefits of Using Schneider LC1D25M7

Efficiency

it is engineered to maximize efficiency, reducing energy wastage and enhancing overall system performance.

Reliability

Known for its sturdy construction, this contactor provides exceptional reliability, ensuring your electrical systems remain operational.

Cost-Effectiveness

By optimizing energy use and minimizing the need for frequent replacements, it proves to be a cost-effective solution over time.

Comparing Schneider LC1D25M7 with Other Models

Schneider Models

Within the Schneider Electric range, it is distinguished by its advanced features and superior performance relative to other models.

Competitor Models

When compared to competitor models, it often excels in terms of reliability, efficiency, and comprehensive safety features.

Maintenance Tips

Regular Checks

Regular inspections ensure that the contactor is functioning correctly. Look for signs of wear and tear and address them promptly to avoid major issues.

Troubleshooting Common Issues

Common problems may include tripping circuits or unusual noises. Refer to the user manual for troubleshooting tips or contact Schneider Electric support for help.

Energy Efficiency

How it Conserves Energy

it is designed to optimize energy use, significantly reducing your energy footprint.

Impact on Utility Bills

By conserving energy, this contactor can help lower your utility bills, making it a wise investment for both residential and commercial use.

SKU: LC1D25M7 Category: Brand:
Main
Range of producTeSys Deca
Product or component typeContactor
Device short nameLC1D
contactor applicationMotor control
Resistive load
utilisation categoryAC-1
AC-3
AC-4
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Complementary
Motor power kW5.5 kW at 220…230 V AC 50/60 Hz (AC-3)
11 kW at 380…400 V AC 50/60 Hz (AC-3)
11 kW at 415…440 V AC 50/60 Hz (AC-3)
15 kW at 500 V AC 50/60 Hz (AC-3)
15 kW at 660…690 V AC 50/60 Hz (AC-3)
5.5 kW at 400 V AC 50/60 Hz (AC-4)
5.5 kW at 220…230 V AC 50/60 Hz (AC-3e)
11 kW at 380…400 V AC 50/60 Hz (AC-3e)
11 kW at 415…440 V AC 50/60 Hz (AC-3e)
15 kW at 500 V AC 50/60 Hz (AC-3e)
15 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 115 V AC 50/60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
15 hp at 460/480 V AC 50/60 Hz for 3 phases motors
20 hp at 575/600 V AC 50/60 Hz for 3 phases motors
7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Contact compatibilityM2
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current240 A 40 °C – 10 s for power circuit
380 A 40 °C – 1 s for power circuit
50 A 40 °C – 10 min for power circuit
120 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
Average impedance2 mOhm – Ith 40 A 50 Hz for power circuit
Power dissipation per pole3.2 W AC-1
1.25 W AC-3
1.25 W AC-3e
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability1.65 Mcycles 25 A AC-3 at Ue <= 440 V
1.4 Mcycles 40 A AC-1 at Ue <= 440 V
1.65 Mcycles 25 A AC-3e at Ue <= 440 V
Control circuit typeAC at 50/60 Hz standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time12…22 ms closing
4…19 ms opening
Maximum operating rate3600 cyc/h 60 °C
Connections – terminalsControl circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typeType mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
mounting supportPlate
Rail
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
product certificationsBV
GL
LROS (Lloyds register of shipping)
GOST
UL
DNV
CCC
CSA
RINA
UKCA
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandConforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
height85 mm
Width45 mm
Depth92 mm
Net weight0.37 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width9.300 cm
Package 1 Length11.400 cm
Package 1 Weight413.000 g
Unit Type of Package 2S02
Number of Units in Package 220
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.440 kg
Unit Type of Package 3P06
Number of Units in Package 3320
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight143.000 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LC1D25M7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D25M7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 25 A – 220 V AC coil”

There are no reviews yet.

SHOPPING CART