Let's Chat
-46%

Schneider LC1D32E7 Contactor | TeSys D – 3P(3 NO) – AC-3 – <= 440 V 32 A – 48 V AC coil

Schneider Electric
Availability:

In stock


Schneider LC1D32E7 Contactor

3,238 EGP 5,996 EGP

In stock

Compare

Schneider LC1D32E7 Contactor

Schneider LC1D32E7 Contactor is a crucial component in electrical systems, known for its reliability and performance. Let’s delve deeper into its features, applications, and advantages.

Understanding What a Contactor Is

Before discussing the Schneider LC1D32E7 model, it’s essential to understand the concept of a contactor. A contactor is an electrically-controlled switch used for switching an electrical power circuit, similar to a relay but with higher current ratings. It is commonly used for controlling electric motors and lighting systems.

Specifications of Schneider LC1D32E7 Contactor

The Schneider LC1D32E7 Contactor comes with specific technical specifications to ensure compatibility and optimal performance. These include voltage rating, current rating, coil voltage, and frequency requirements.

Voltage Rating

The voltage rating of the LC1D32E7 Contactor determines the maximum voltage it can safely handle. It is crucial to match the voltage rating of the contactor with the electrical system it will be installed in to prevent damage and ensure safety.

Current Rating

The current rating indicates the maximum current that the contactor can carry continuously without overheating or malfunctioning. It is a critical parameter to consider when selecting a contactor for a particular application, ensuring it can handle the electrical load.

Coil Voltage

The coil voltage determines the voltage required to energize the contactor and close its contacts. It is essential to ensure compatibility with the control circuit voltage to enable proper operation.

Frequency

The frequency specification specifies the operating frequency range of the contactor. It is essential to select a contactor that matches the frequency of the electrical system to ensure reliable performance.

Applications of Schneider LC1D32E7 Contactor

The Schneider LC1D32E7 Contactor finds widespread applications across various industries and sectors due to its versatility and reliability.

Industrial Machinery

In industrial settings, the LC1D32E7 Contactor is commonly used for controlling motors, pumps, compressors, and other heavy-duty machinery. Its robust design and high current handling capabilities make it suitable for demanding applications.

HVAC Systems

In heating, ventilation, and air conditioning (HVAC) systems, the LC1D32E7 Contactor is utilized for controlling the operation of compressors, fans, and other HVAC components. Its reliable performance ensures efficient and uninterrupted operation of HVAC systems.

Motor Control Circuits

The LC1D32E7 Contactor is widely used in motor control circuits for starting, stopping, and reversing the rotation of electric motors. It provides a reliable and efficient means of controlling motor-driven equipment in various industrial and commercial applications.

Features of Schneider LC1D32E7 Contactor

The Schneider LC1D32E7 Contactor is packed with features that make it a preferred choice for electrical contractors and engineers.

Compact Design

Despite its robust construction, the LC1D32E7 Contactor boasts a compact design, making it easy to integrate into existing electrical panels and enclosures. Its space-saving design is ideal for applications with limited space constraints.

High Durability

Constructed from high-quality materials, the LC1D32E7 Contactor is built to withstand harsh operating conditions, including temperature extremes, humidity, and mechanical stress. Its durable construction ensures long-term reliability and performance.

Easy Installation

The LC1D32E7 Contactor is designed for easy installation, with clearly labeled terminals and mounting provisions. Its user-friendly design simplifies the installation process, reducing downtime and labor costs.

Main
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 48 V AC 50/60 Hz
Complementary
Motor power kW 7.5 kW at 220…230 V AC 50/60 Hz (AC-3)
15 kW at 380…400 V AC 50/60 Hz (AC-3)
15 kW at 415…440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660…690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC-4)
7.5 kW at 220…230 V AC 50/60 Hz (AC-3e)
15 kW at 380…400 V AC 50/60 Hz (AC-3e)
15 kW at 415…440 V AC 50/60 Hz (AC-3e)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp 2 hp at 115 V AC 50/60 Hz for 1 phase motors
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
20 hp at 460/480 V AC 50/60 Hz for 3 phases motors
25 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
50 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
550 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 260 A 40 °C – 10 s for power circuit
430 A 40 °C – 1 s for power circuit
60 A 40 °C – 10 min for power circuit
138 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
63 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2 mOhm – Ith 50 A 50 Hz for power circuit
Power dissipation per pole 2 W AC-3
5 W AC-1
2 W AC-3e
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 1.65 Mcycles 32 A AC-3 at Ue <= 440 V
1.4 Mcycles 50 A AC-1 at Ue <= 440 V
1.65 Mcycles 32 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz
Operating time 12…22 ms closing
4…19 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1
Product certifications UL
CCC
CSA
Marine
UKCA
EAC
CB Scheme
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
Height 85 mm
Width 45 mm
Depth 92 mm
Net weight 0.375 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.0 cm
Package 1 Width 9.2 cm
Package 1 Length 11.2 cm
Package 1 Weight 420.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 20
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 8.935 kg
Unit Type of Package 3 P06
Number of Units in Package 3 320
Package 3 Height 77.0 cm
Package 3 Width 80.0 cm
Package 3 Length 60.0 cm
Package 3 Weight 150.18 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet LC1D32E7 
Instruction sheet
Download
Catalogue
Download
CAD Files
Download
Environmental disclosure Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D32E7 Contactor | TeSys D – 3P(3 NO) – AC-3 – <= 440 V 32 A – 48 V AC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024