Schneider LC1D38Q7 Contactor: A Reliable Solution for Your Electrical Needs

In the realm of electrical engineering, efficiency, reliability, and safety are paramount concerns. Whether you’re dealing with industrial machinery, HVAC systems, or lighting control, having the right components can make all the difference. One such crucial component is the contactor, and among the myriad options available, the Schneider LC1D38Q7 stands out as a top choice for discerning professionals.

Understanding Contactor Basics

What is a contactor?

A contactor is an electrical device primarily used for switching an electrical circuit on or off. It consists of a set of contacts that are opened or closed by the electromagnetic coil when power is applied.

Importance of contactors in electrical systems

Contactors play a vital role in controlling the flow of electricity within various systems, ensuring smooth operation and preventing damage due to overload or short circuits.

Features of Schneider LC1D38Q7 Contactor

Capacity and Rating

The Schneider LC1D38Q7 Contactor boasts impressive capacity and rating, making it suitable for heavy-duty applications. With a rated operational current of 38A, it can handle substantial electrical loads with ease.

Coil Voltage Options

One of the key features of the LC1D38Q7 is its versatility in coil voltage options. Available in multiple voltages, including 24V, 120V, and 240V, it offers flexibility to accommodate different electrical setups.

Auxiliary Contacts

Equipped with auxiliary contacts, this contactor allows for enhanced control and monitoring of electrical circuits. These additional contacts provide auxiliary functions such as signaling or interlocking, expanding the functionality of the contactor.

Safety Features

Safety is paramount in any electrical system, and the LC1D38Q7 prioritizes this aspect with features like built-in surge suppression and arc suppression. These safety mechanisms help prevent damage to the contactor and ensure reliable operation under varying conditions.

Applications of Schneider LC1D38Q7 Contactor

The versatility of the Schneider LC1D38Q7 makes it suitable for a wide range of applications, including:

  • Industrial Machinery: From motor control to conveyor systems, the LC1D38Q7 excels in industrial settings where robust performance is essential.
  • HVAC Systems: Heating, ventilation, and air conditioning systems rely on precise control of electrical components, making the LC1D38Q7 an ideal choice for HVAC applications.
  • Lighting Control: Whether it’s in commercial buildings or outdoor lighting installations, the LC1D38Q7 ensures efficient and reliable control of lighting circuits.

Installation and Wiring

Proper installation is crucial for optimal performance and safety. When installing the Schneider LC1D38Q7 Contactor, adhere to manufacturer guidelines and consider factors such as proper mounting, adequate ventilation, and correct wiring techniques to prevent issues down the line.

Maintenance and Troubleshooting

Regular maintenance helps prolong the lifespan of the contactor and ensures continued reliability. Inspect the contactor periodically for signs of wear or damage, and address any issues promptly. Common troubleshooting steps include checking for loose connections, testing the coil, and verifying proper voltage levels.

Benefits of Schneider LC1D38Q7 Contactor

Improved Efficiency

By providing reliable switching and control of electrical circuits, the LC1D38Q7 contributes to overall system efficiency, reducing downtime and optimizing energy usage.

Enhanced Safety

With built-in safety features and robust construction, the LC1D38Q7 prioritizes safety in electrical applications, mitigating risks associated with overload, short circuits, and other potential hazards.

Cost-Effectiveness

Despite its advanced features and high performance, the Schneider LC1D38Q7 offers excellent value for money, delivering long-term reliability and durability at a competitive price point.

Comparison with Competing Products

In comparison to other contactors in the market, the Schneider LC1D38Q7 stands out for its superior performance, reliability, and versatility. While there may be alternatives available, few can match the overall quality and features offered by the LC1D38Q7.

Main
Range TeSys
TeSys Deca
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
38 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 380 V AC 50/60 Hz
Complementary
Motor power kW 18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660…690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380…400 V AC 50/60 Hz (AC-3)
9 kW at 220…230 V AC 50/60 Hz (AC-3)
18.5 kW at 415…440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660…690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
9 kW at 220…230 V AC 50/60 Hz (AC-3e)
18.5 kW at 415…440 V AC 50/60 Hz (AC-3e)
Motor power hp 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
5 hp at 240 V AC 50/60 Hz for 1 phase motors
20 hp at 480 V AC 50/60 Hz for 3 phases motors
25 hp at 600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
50 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
550 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 60 A 40 °C – 10 min for power circuit
430 A 40 °C – 1 s for power circuit
150 A 40 °C – 1 min for power circuit
310 A 40 °C – 10 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
63 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2 mOhm – Ith 50 A 50 Hz for power circuit
Power dissipation per pole 5 W AC-1
3 W AC-3
3 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 1.4 Mcycles 50 A AC-1 at Ue <= 440 V
1.4 Mcycles 38 A AC-3 at Ue <= 440 V
1.4 Mcycles 38 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz
Operating time 4…19 ms opening
12…22 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1
Product certifications UL
CCC
CSA
Marine
UKCA
EAC
CB Scheme
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
Height 85 mm
Width 45 mm
Depth 92 mm
Net weight 0.38 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.2 cm
Package 1 Width 9.6 cm
Package 1 Length 5 cm
Package 1 Weight 410 g
Unit Type of Package 2 S02
Number of Units in Package 2 20
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 8.597 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet LC1D38Q7 
Instruction sheet
Download
Catalogue
Download
CAD Files
Download
Environmental disclosure Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D38Q7 Contactor | TeSys D – 3P(3 NO) – AC-3 – <= 440 V 38 A – 380 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024