Schneider LC1D40AB7 3P: A Comprehensive Overview

Introduction

it holds a pivotal role in the landscape of industrial automation and control systems. This guide aims to provide an in-depth understanding of its features, applications, and significance in various industries.

What is the Schneider LC1D40AB7 3P?

Overview

it is a robust and versatile contactor designed to streamline industrial control processes.

Key Features

With advanced features and precision engineering, it ensures reliable performance and seamless operation in diverse environments.

Applications

From manufacturing plants to commercial facilities,it finds extensive application in controlling electrical circuits and machinery.

Understanding the Specifications

Voltage Ratings

The device operates within specific voltage ranges, ensuring compatibility with various electrical systems.

Contact Configuration

Its precise contact configuration enables accurate signaling and control, essential for optimizing industrial processes.

Environmental Specifications

Built to withstand harsh conditions, it boasts resilience against temperature variations and environmental contaminants.

Installation and Setup

Mounting Options

Flexible mounting options allow for seamless integration into existing infrastructures, catering to diverse installation requirements.

Wiring Guidelines

Clear and concise wiring guidelines simplify installation, reducing setup time and ensuring operational readiness.

Integration with Control Systems

it seamlessly integrates with a range of control systems, enhancing interoperability and system efficiency.

Operational Capabilities

Switching Mechanism

Its responsive switching mechanism ensures prompt execution of commands, contributing to operational agility.

Response Time

With minimal response times, it facilitates swift decision-making and precise control in dynamic operational scenarios.

Durability

Built to endure rigorous usage, it boasts exceptional durability, minimizing downtime and maximizing productivity.

Safety Considerations

Overload Protection

Incorporating overload protection mechanisms, it prioritizes safety by mitigating risks associated with excessive currents.

Environmental Resistance

Its robust construction renders it resistant to environmental stressors, ensuring reliable performance in challenging conditions.

Compliance Standards

Compliant with industry standards, the Schneider LC1D40AB7 3P adheres to stringent quality and safety protocols, instilling confidence in its reliability.

Comparative Analysis

Versus Competitors

In comparison to alternatives, it stands out for its superior performance, reliability, and cost-effectiveness.

Advantages Over Alternatives

Its advanced features and competitive pricing make it a preferred choice among industrial professionals seeking optimal automation solutions.

Cost Efficiency

Offering a compelling blend of performance and affordability, it delivers long-term value and cost savings.

Maintenance and Troubleshooting

Routine Maintenance

Simple maintenance procedures ensure prolonged lifespan and consistent performance, minimizing downtime.

Common Issues and Solutions

Comprehensive troubleshooting resources expedite issue resolution, empowering users to address challenges efficiently.

Professional Support

Dedicated customer support channels provide timely assistance, ensuring smooth operation and maximum uptime.

Future Trends and Innovations

Technological Advancements

Continual innovation drives the evolution of the Schneider LC1D40AB7 3P, introducing new features to meet evolving industry demands.

Industry Adoption

As industries embrace automation, the demand for reliable control solutions like it is poised to increase, driving widespread adoption.

Predictions

Anticipating future trends, Schneider Electric remains committed to enhancing it, positioning it as a cornerstone of industrial automation.

Conclusion

In conclusion, it emerges as an indispensable asset in industrial automation, embodying reliability, efficiency, and innovation. Its diverse features and applications underscore its significance in streamlining operations and driving productivity across industries.

SKU: LC1D40AB7 Category: Brand:
Main
RangeTeSys
TeSys Deca
Range of productTeSys Deca
product or component typeContactor
Device short nameLC1D
contactor applicationMotor control
Resistive load
Utilisation categoryAC-4
AC-1
AC-3
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage24 V AC 50/60 Hz
Complementary
Motor power kW18.5 kW at 380…400 V AC 50/60 Hz (AC-3)
11 kW at 220…230 V AC 50/60 Hz (AC-3)
22 kW at 415…440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660…690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
11 kW at 220…230 V AC 50/60 Hz (AC-3e)
22 kW at 415…440 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
30 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 115 V AC 50/60 Hz for 1 phase motors
30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 40 °C – 10 s for power circuit
720 A 40 °C – 1 s for power circuit
72 A 40 °C – 10 min for power circuit
165 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.5 mOhm – Ith 60 A 50 Hz for power circuit
Power dissipation per pole2.4 W AC-3
5.4 W AC-1
2.4 W AC-3e
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.4 Mcycles 60 A AC-1 at Ue <= 440 V
1.5 Mcycles 40 A AC-3 at Ue <= 440 V
1.5 Mcycles 40 A AC-3e at Ue <= 440 V
Control circuit typeAC at 50/60 Hz standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50/60 Hz
Operating time4…19 ms opening
12…26 ms closing
Maximum operating rate3600 cyc/h 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible without cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: solid without cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typeType mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportPlate
Rail
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
Product certificationsUL
GOST
CSA
CCC
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandConforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Height122 mm
Width55 mm
Depth120 mm
net weight0.85 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.2 cm
Package 1 Width13.5 cm
Package 1 Length15.5 cm
Package 1 Weight917.0 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight9.906 kg
Unit Type of Package 3P06
Number of Units in Package 3160
Package 3 Height77.0 cm
Package 3 Width80.0 cm
Package 3 Length60.0 cm
Package 3 Weight166.98 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews