Understanding the Schneider LC1D40AF7 Contactor: A Comprehensive Guide

Introduction

In the world of electrical components, Schneider Electric stands out as a trusted name, renowned for its high-quality products and innovative solutions. Among its wide range of offerings, it contactor is a notable component that plays a crucial role in various electrical systems. In this article, we’ll delve into the intricacies of the Schneider LC1D40AF7, exploring its features, applications, installation, and more.

What is a Contactor?

A contactor is an electrically controlled switch used for switching an electrical power circuit. It is typically used to control electric motors, lighting, heating, and other electrical loads. Unlike relays, contactors are designed to handle higher current loads, making them suitable for more demanding applications.

Schneider Electric: A Trusted Brand

History of Schneider Electric

Schneider Electric has a rich history dating back to the 19th century. Founded in 1836, the company has grown to become a global leader in energy management and automation solutions. Schneider Electric’s commitment to quality and innovation has made it a preferred choice for electrical components worldwide.

Importance of Quality and Reliability

When it comes to electrical components, quality and reliability are paramount. Schneider Electric’s products are known for their durability and performance, ensuring that systems run smoothly and safely. it is no exception, offering robust performance in various applications.

Features of the Schneider LC1D40AF7

Electrical Specifications

it contactor boasts impressive electrical specifications, making it a versatile choice for different settings. It can handle high voltage and current ratings, ensuring efficient operation even under heavy loads.

Physical Dimensions

This contactor is designed with compact dimensions, allowing for easy integration into existing systems without requiring extensive modifications. Its size makes it suitable for use in both confined and spacious environments.

Material and Build Quality

Built with high-quality materials, it is designed to withstand harsh conditions and prolonged use. Its robust construction ensures longevity and reliability, reducing the need for frequent replacements.

Technical Specifications

Voltage Ratings

it is designed to operate within a specific voltage range, typically up to 690V AC. This wide range allows it to be used in various electrical systems without compatibility issues.

Current Ratings

With a current rating of 40A, this contactor is capable of handling substantial electrical loads, making it suitable for industrial and commercial applications where high current handling is required.

Operating Frequency

The contactor operates efficiently within a frequency range of 25-400Hz, providing flexibility for use in different environments and applications.

Applications of Schneider LC1D40AF7

Industrial Applications

In industrial settings, it is commonly used to control machinery and equipment. Its high current handling capacity and reliability make it ideal for heavy-duty operations.

Commercial Applications

For commercial buildings, this contactor is used in HVAC systems, lighting control, and other electrical systems that require reliable switching mechanisms.

Residential Applications

Even in residential settings, it finds use in controlling home automation systems, ensuring safe and efficient operation of various electrical devices.

Installation Guide

Pre-installation Checks

Before installing the Schneider LC1D40AF7, it’s essential to conduct thorough pre-installation checks. This includes verifying the voltage and current requirements, ensuring compatibility with the existing system, and inspecting the contactor for any physical damage.

Step-by-step Installation Process

  1. Turn off the Power: Ensure the power supply to the installation area is completely turned off.
  2. Mount the Contactor: Securely mount the contactor in the designated location using appropriate mounting hardware.
  3. Connect the Wires: Follow the wiring diagram provided by Schneider Electric to connect the wires correctly.
  4. Test the Connections: Double-check all connections to ensure they are secure and correctly configured.
  5. Power Up: Turn the power back on and test the contactor to ensure it operates as expected.

Safety Precautions

Safety is paramount when working with electrical components. Always wear appropriate personal protective equipment (PPE), follow all safety guidelines, and consult a professional electrician if unsure about any part of the installation process.

Maintenance Tips

Regular Inspection Procedures

Regular inspections are crucial to maintaining the performance and longevity of the Schneider LC1D40AF7. Check for signs of wear, corrosion, or any abnormalities in the contactor’s operation.

Cleaning and Servicing

Keeping the contactor clean is essential for optimal performance. Use appropriate cleaning agents to remove dust and debris, and ensure all connections are tight and corrosion-free.

Common Issues and Troubleshooting

Common issues with contactors include coil failure, contact welding, and mechanical wear. Identifying and addressing these issues promptly can prevent system failures and extend the contactor’s lifespan.

Advantages of Using Schneider LC1D40AF7

Durability and Longevity

One of the standout features of the LC1D40AF7 is its durability. Built to withstand rigorous use, this contactor offers a long service life, making it a cost-effective choice for various applications.

 

SKU: LC1D40AF7 Category:
Main
Range TeSys
TeSys Deca
Range of produc TeSys Deca
Product or component type Contactor
Device short name LC1D
contactor application Resistive load
Motor control
utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 110 V AC 50/60 Hz
Complementary
Motor power kW 18.5 kW at 380…400 V AC 50/60 Hz (AC-3)
11 kW at 220…230 V AC 50/60 Hz (AC-3)
22 kW at 415…440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660…690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
11 kW at 220…230 V AC 50/60 Hz (AC-3e)
22 kW at 415…440 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
30 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 115 V AC 50/60 Hz for 1 phase motors
30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 320 A 40 °C – 10 s for power circuit
720 A 40 °C – 1 s for power circuit
72 A 40 °C – 10 min for power circuit
165 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm – Ith 60 A 50 Hz for power circuit
Power dissipation per pole 2.4 W AC-3
5.4 W AC-1
2.4 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 6 Mcycles
Electrical durability 1.4 Mcycles 60 A AC-1 at Ue <= 440 V
1.5 Mcycles 40 A AC-3 at Ue <= 440 V
1.5 Mcycles 40 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50/60 Hz
Operating time 4…19 ms opening
12…26 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible without cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: solid without cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
mounting support Rail
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
product certifications CCC
CSA
GOST
UL
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand Conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
height 122 mm
Width 55 mm
Depth 120 mm
Net weight 0.85 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.2 cm
Package 1 Width 13.5 cm
Package 1 Length 15.5 cm
Package 1 Weight 920.0 g
Unit Type of Package 2 P06
Number of Units in Package 2 160
Package 2 Height 75.0 cm
Package 2 Width 80.0 cm
Package 2 Length 60.0 cm
Package 2 Weight 166.34 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1D40AF7 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D40AF7 | 3P CONT 40 AC3 18.5KW 1NO 1NC 110VAC”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024