In today’s rapidly evolving world of electrical engineering, having reliable components is crucial for ensuring the smooth operation of various systems. One such indispensable component is the Schneider LC1D40AQ7 Contactor. In this article, we will delve into the features, applications, advantages, and installation of this essential electrical device.

Introduction to Schneider LC1D40AQ7 Contactor

The Schneider LC1D40AQ7 Contactor is a high-performance electrical component designed for switching and controlling electrical power circuits. It is part of Schneider Electric’s renowned line of contactors, known for their reliability and durability in demanding industrial environments.

What is a Contactor?

A contactor is an electromechanical switch used to make or break electrical connections in power circuits. Unlike relays, which are typically used for low-power applications, contactors are designed to handle higher currents and voltages, making them suitable for controlling motors, lighting, heating systems, and other heavy-duty electrical loads.

Understanding Contactors

Before delving into the specifics of the Schneider LC1D40AQ7 Contactor, let’s first understand the basic principles behind contactors and their role in electrical systems.

Features of Schneider LC1D40AQ7 Contactor

The Schneider LC1D40AQ7 Contactor boasts a range of features that set it apart from other contactors on the market. Some of its key features include:

  • High current rating: The LC1D40AQ7 is capable of handling currents up to 40 amps, making it suitable for a wide range of industrial applications.
  • Compact design: Despite its robust performance, the LC1D40AQ7 has a compact footprint, making it easy to integrate into electrical panels and control systems.
  • Coil voltage options: Schneider offers a variety of coil voltage options for the LC1D40AQ7, allowing for compatibility with different electrical systems and voltage standards.
  • Built-in surge suppression: The LC1D40AQ7 is equipped with built-in surge suppression to protect sensitive electronic components from voltage spikes and transients.
  • Long electrical life: With its durable construction and high-quality materials, the LC1D40AQ7 is designed to provide years of reliable service in demanding industrial environments.

Applications of Schneider LC1D40AQ7 Contactor

The Schneider LC1D40AQ7 Contactor finds applications in a wide range of industries and systems, including:

  • Motor control: The LC1D40AQ7 is commonly used to control the operation of motors in industrial machinery, conveyor systems, and HVAC equipment.
  • Lighting control: In commercial and industrial settings, the LC1D40AQ7 can be used to switch and dim lighting circuits, providing energy-efficient control of lighting systems.
  • Heating systems: The LC1D40AQ7 is ideal for controlling electric heating elements in ovens, furnaces, and other heating systems, ensuring precise temperature regulation and energy efficiency.

Advantages of Using Schneider LC1D40AQ7 Contactor

Choosing the Schneider LC1D40AQ7 Contactor offers several advantages:

  • Reliability: Schneider Electric is a trusted name in the industry, known for producing high-quality electrical components that deliver reliable performance in demanding environments.
  • Durability: The LC1D40AQ7 is built to withstand the rigors of industrial use, with a rugged construction that ensures long-term reliability and durability.
  • Performance: With its high current rating and advanced features, the LC1D40AQ7 delivers superior performance in a wide range of applications, from motor control to lighting and heating systems.

Installation Guide

Installing the Schneider LC1D40AQ7 Contactor is a straightforward process, but it’s important to follow proper installation procedures to ensure safe and reliable operation. Here’s a step-by-step guide:

  1. Choose the right location: Select a suitable location for mounting the LC1D40AQ7 Contactor, taking into account factors such as accessibility, ventilation, and proximity to other electrical components.
  2. Prepare the electrical panel: Before installing the LC1D40AQ7, ensure that the electrical panel is properly grounded and that
Main
Range TeSys
TeSys Deca
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 380 V AC 50/60 Hz
Complementary
Motor power kW 18.5 kW at 380…400 V AC 50/60 Hz (AC-3)
11 kW at 220…230 V AC 50/60 Hz (AC-3)
22 kW at 415…440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660…690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
11 kW at 220…230 V AC 50/60 Hz (AC-3e)
22 kW at 415…440 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
30 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 115 V AC 50/60 Hz for 1 phase motors
30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 320 A 40 °C – 10 s for power circuit
720 A 40 °C – 1 s for power circuit
72 A 40 °C – 10 min for power circuit
165 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm – Ith 60 A 50 Hz for power circuit
Power dissipation per pole 2.4 W AC-3
5.4 W AC-1
2.4 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 6 Mcycles
Electrical durability 1.4 Mcycles 60 A AC-1 at Ue <= 440 V
1.5 Mcycles 40 A AC-3 at Ue <= 440 V
1.5 Mcycles 40 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50/60 Hz
Operating time 4…19 ms opening
12…26 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Plate
Rail
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
Product certifications CCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Height 122 mm
Width 55 mm
Depth 120 mm
Net weight 0.85 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.200 cm
Package 1 Width 13.700 cm
Package 1 Length 15.200 cm
Package 1 Weight 906.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 10
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.336 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet LC1D40AQ7
Instruction sheet
Download
Catalog Download
CAD Files
Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D40AQ7 Contactor | TeSys D- 3P(3 NO) – AC-3 – <= 440 V 40 A – 380 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024