Schneider LC1D65AF7| TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 65 A – 110 V AC 50/60 Hz coil

Schneider LC1D65AF7 Description

Introduction to Schneider LC1D65AF7

The Schneider LC1D65AF7 is a powerful and reliable contactor designed for various industrial applications. This article provides a comprehensive description of the LC1D65AF7, including its specifications, features, applications, advantages, and installation procedures.

Specifications of LC1D65AF7

The LC1D65AF7 is a three-pole contactor with a voltage rating of up to 690V AC and a current rating of 65A. It operates with a coil voltage of 24V AC/DC, providing flexibility in different electrical systems.

Features of Schneider LC1D65AF7

TeSys D Contactor

The LC1D65AF7 belongs to the TeSys D range of contactors, known for their high performance and reliability. It features robust construction and durable materials, ensuring long-term operation in harsh industrial environments.

Compact Design

Despite its high power handling capacity, the LC1D65AF7 boasts a compact and space-saving design. This makes it suitable for installations where space is limited, without compromising on performance.

Easy Installation

Installing the LC1D65AF7 is straightforward, thanks to its user-friendly design and clear labeling of terminals. It comes with detailed installation instructions, enabling electricians to set it up quickly and efficiently.

Applications of LC1D65AF7

The Schneider LC1D65AF7 is widely used in various industrial sectors, including:

  • Industrial Machinery: It is commonly used in motor control circuits for controlling motors and other heavy-duty equipment.
  • HVAC Systems: The LC1D65AF7 plays a crucial role in controlling the operation of heating, ventilation, and air conditioning systems.
  • Lighting Control: It can be employed in lighting control panels for switching and controlling lighting circuits in commercial and industrial buildings.

Advantages of Using LC1D65AF7

Reliability

The LC1D65AF7 is built to withstand tough operating conditions, ensuring reliable performance even in demanding environments.

Energy Efficiency

With its efficient design and low power consumption, the LC1D65AF7 helps minimize energy wastage and reduce operational costs.

Safety Features

The contactor is equipped with various safety features, including overload protection and built-in surge suppression, ensuring the safety of both equipment and personnel.

Comparison with Other Contactors

Compared to traditional contactors, the LC1D65AF7 offers superior performance, reliability, and versatility, making it the preferred choice for many industrial applications.

Installation and Maintenance of LC1D65AF7

Wiring Procedures

Proper wiring is essential for the safe and reliable operation of the LC1D65AF7. Electricians should follow the manufacturer’s guidelines and wiring diagrams to ensure correct connections.

Safety Precautions

During installation and maintenance, proper safety precautions must be followed to prevent accidents and injuries. This includes de-energizing the circuit, using appropriate personal protective equipment, and following lockout/tagout procedures.

Maintenance Tips

Regular maintenance is key to prolonging the lifespan of the LC1D65AF7 and ensuring optimal performance. This includes periodic inspection, cleaning, and testing of the contactor and associated components.

Troubleshooting Common Issues

Despite its reliability, the LC1D65AF7 may encounter issues such as overheating, coil failure, or contact welding. Understanding these common issues and their causes is essential for effective troubleshooting and timely resolution.

Customer Reviews and Feedback

Customers who have used the Schneider LC1D65AF7 praise its reliability, performance, and ease of installation. Many have reported significant improvements in their industrial processes after switching to the LC1D65AF7.

Conclusion

In conclusion, the Schneider LC1D65AF7 is a high-quality contactor that offers superior performance, reliability, and safety features. Its compact design, easy installation, and versatile applications make it the ideal choice for various industrial needs.

Main
Range TeSys
TeSys Deca
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-4
AC-1
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 110 V AC 50/60 Hz
Complementary
Motor power kW 11 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 220…230 V AC 50/60 Hz (AC-3)
30 kW at 380…400 V AC 50/60 Hz (AC-3)
37 kW at 500 V AC 50/60 Hz (AC-3)
37 kW at 660…690 V AC 50/60 Hz (AC-3)
18.5 kW at 220…230 V AC 50/60 Hz (AC-3e)
30 kW at 380…400 V AC 50/60 Hz (AC-3e)
37 kW at 500 V AC 50/60 Hz (AC-3e)
37 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors
5 hp at 115 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 1 phase motors
20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
20 hp at 230/240 V AC 50/60 Hz for 3 phases motors
50 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 640 A 40 °C – 10 s for power circuit
900 A 40 °C – 1 s for power circuit
110 A 40 °C – 10 min for power circuit
260 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm – Ith 80 A 50 Hz for power circuit
Power dissipation per pole 9.6 W AC-1
6.3 W AC-3
6.3 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 6 Mcycles
Electrical durability 1.4 Mcycles 80 A AC-1 at Ue <= 440 V
1.45 Mcycles 65 A AC-3 at Ue <= 440 V
1.45 Mcycles 65 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50/60 Hz
Operating time 4…19 ms opening
12…26 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible without cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw connection 1 1…35 mm² – cable stiffness: solid without cable end
Power circuit: screw connection 2 1…25 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on EverLink BTR screw connectors – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product certifications CCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Height 122 mm
Width 55 mm
Depth 120 mm
Net weight 0.86 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.100 cm
Package 1 Width 1.100 cm
Package 1 Length 1.100 cm
Package 1 Weight 1.100 kg
Unit Type of Package 2 S02
Number of Units in Package 2 10
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 10.3 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D65AF7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 65 A – 110 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024