-48%

Schneider LC1D80AM7 | TeSys D contactor 3P 66A AC-3 up to 440V coil 220V AC 50/60Hz

Schneider Electric
Availability:

In stock


7,498.92 EGP 14,421.00 EGP

In stock

Schneider LC1D80AM7| TeSys D contactor 3P 66A AC-3 up to 440V coil 220V AC 50/60Hz

Schneider LC1D80AM7 Contactor: A Comprehensive Overview

it is a robust and efficient contactor, part of the highly reliable TeSys D range by Schneider Electric. This device is engineered to meet the rigorous demands of industrial and commercial electrical applications. Below, we explore its key specifications, features, and benefits.

Key Specifications

  • Model: LC1D80AM7
  • Range: TeSys D
  • Rated Operational Current (AC-3): 80A
  • Rated Operational Voltage (Ue): Up to 690V AC
  • Control Circuit Voltage: 220V AC (50/60 Hz)
  • Number of Poles: 3P (Three Poles)
  • Utilization Category: AC-3 and AC-4
  • Conformity Standards: IEC 60947, EN 60947

Main Features

  1. High Durability:
    • it is designed for long operational life with high electrical and mechanical endurance.
  2. Compact Design:
    • Its streamlined structure allows easy integration into various control panels without consuming excessive space.
  3. Enhanced Performance:
    • Efficient in controlling motors up to 37 kW at 400V under AC-3 duty, making it ideal for heavy-duty applications.
  4. Safety Features:
    • Equipped with protective features to ensure safe and reliable operation under different load conditions.
  5. Energy Efficiency:
    • Reduces power consumption in the control circuit, contributing to energy savings.

Applications

it is suitable for:

  • Industrial machinery control systems.
  • HVAC systems.
  • Pumps and compressors.
  • Conveyor belts.
  • Motor switching and control for automation processes.

Installation and Compatibility

  • Mounting Options:
    • DIN rail or panel-mounted, ensuring flexibility for various configurations.
  • Auxiliary Components:
    • Compatible with a wide range of accessories, such as auxiliary contact blocks and surge suppressors, to expand its functionality.

Benefits of Using

  1. Reliability:
    • Proven performance even under harsh operating conditions.
  2. Ease of Maintenance:
    • Simplified design facilitates quick installation and servicing.
  3. Cost-Effective:
    • Offers a balance between price and advanced features, ensuring value for investment.
  4. Global Standards Compliance:
    • Adheres to international safety and performance standards.
Main
Range TeSys
TeSys Deca
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-1
AC-4
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: 690 V AC 25…400 Hz
Power circuit: 300 V DC
[Ie] rated operational current 80 A (at <60 °C) at <= 440 V AC-1 for power circuit
66 A (at <60 °C) at <= 440 V AC-3 for power circuit
66 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Complementary
Motor power kW 22 kW at 220…230 V AC 50/60 Hz (AC-3)
37 kW at 380…400 V AC 50/60 Hz (AC-3)
37 kW at 415 V AC 50/60 Hz (AC-3)
37 kW at 440 V AC 50/60 Hz (AC-3)
37 kW at 500 V AC 50/60 Hz (AC-3)
37 kW at 660…690 V AC 50/60 Hz (AC-3)
22 kW at 220…230 V AC 50/60 Hz (AC-3e)
37 kW at 380…400 V AC 50/60 Hz (AC-3e)
37 kW at 415 V AC 50/60 Hz (AC-3e)
37 kW at 440 V AC 50/60 Hz (AC-3e)
37 kW at 500 V AC 50/60 Hz (AC-3e)
37 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp 5 hp at 115 V AC 60 Hz for 1 phase motors
10 hp at 230/240 V AC 60 Hz for 1 phase motors
20 hp at 200/208 V AC 60 Hz for 3 phases motors
20 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
50 hp at 575/600 V AC 60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1000 A at 440 V AC for power circuit conforming to IEC 60947
Rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 640 A 40 °C – 10 s for power circuit
900 A 40 °C – 1 s for power circuit
110 A 40 °C – 10 min for power circuit
260 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm – Ith 80 A 50 Hz for power circuit
Power dissipation per pole 9.6 W AC-1
6.3 W AC-3
6.3 W AC-3e
[Ui] rated insulation voltage Signalling circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 6 Mcycles
Electrical durability 0.7 Mcycles 80 A AC-1 at Ue <= 440 V
1 Mcycles 66 A AC-3 at Ue <= 440 V
1 Mcycles 66 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50/60 Hz
Operating time 4…19 ms opening
12…26 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: solid
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: flexible
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: flexible
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC 60335-1
Product certifications CCC
CSA
EAC
UL
KC
DNV-GL
LROS (Lloyds register of shipping)
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Height 122 mm
Width 55 mm
Depth 120 mm
Net weight 0.86 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.300 cm
Package 1 Width 13.800 cm
Package 1 Length 15.500 cm
Package 1 Weight 926.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 10
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.732 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D80AM7 | TeSys D contactor 3P 66A AC-3 up to 440V coil 220V AC 50/60Hz”

There are no reviews yet.

SHOPPING CART